This comprehensive 16-hour continuing education course is specifically designed for Utah electrical professionals license renewal. The program provides an in-depth analysis of major organizational restructuring within the Code, including the relocation of medium-voltage requirements into new Articles and the overhaul of Chapter 3 wiring methods.
In addition to the 12 hours of core NEC updates, this course includes 4 hours of safety training based on the NFPA 70E 2024 standard. Participants will explore critical changes in arc-flash labeling, GFCI expansion into higher frequencies, new EVSE load management rules, and the most current safety practices for establishing an electrically safe work condition.
Course Objectives
By the end of this course, participants will be able to:
• Identify and locate relocated requirements for medium-voltage systems and service equipment in the 2026 NEC.
• Apply new dwelling unit load calculations and GFCI/AFCI requirements for modern residential and commercial installations.
• Analyze the restructuring of Chapter 3 to correctly apply rules for securing, supporting, and protecting conductors from physical damage.
• Implement safe work practices including lockout/tagout (LOTO) and the proper selection of Personal Protective Equipment (PPE) based on NFPA 70E 2024 standards.
• Evaluate Arc-Flash and Shock Risk Assessments to ensure compliance with federal and state safety regulations.
Course Features
- Lectures 193
- Quizzes 192
- Duration 52 weeks
- Skill level All levels
- Language English
- Students 9
- Certificate Yes
- Assessments Self
- 5 Sections
- 193 Lessons
- NEC 2026: Theory and Calculations89
- 1.1Course Orientation
- 1.2110.10 – How has the focus of Section 110.10 shifted regarding Available Fault Current?
- 1.3110.10 – How has the focus of Section 110.10 shifted regarding Available Fault Current?1 Question
- 1.4110.14 – Are Your Compounds “Identified” or Just “Suitable”?
- 1.5110.14 – Are Your Compounds “Identified” or Just “Suitable”?1 Question
- 1.6110.16 – Arc-Flash Labels: From Generic Warnings to Detailed Markings
- 1.7110.16 – Arc-Flash Labels: From Generic Warnings to Detailed Markings1 Question
- 1.8110.21 – Updating References for Field-Applied Hazard Markings
- 1.9110.21 – Updating References for Field-Applied Hazard Markings1 Question
- 1.10110.24 – How Must Fault Current Labels Be Marked in 2026?
- 1.11110.24 – How Must Fault Current Labels Be Marked in 2026?1 Question
- 1.12110.26 – How Have Working Space Rules Changed for DC Systems and Enclosed Parts?
- 1.13110.26 – How Have Working Space Rules Changed for DC Systems and Enclosed Parts?1 Question
- 1.14110.31 – How have fence clearance requirements changed for High-Voltage DC systems?
- 1.15110.31 – How have fence clearance requirements changed for High-Voltage DC systems?1 Question
- 1.16120.41 – How are Dwelling Unit Load Calculations Changing in 2026?
- 1.17120.41 – How are Dwelling Unit Load Calculations Changing in 2026?1 Question
- 1.18130.1 – Why have Energy Management Systems moved to Chapter 1?
- 1.19130.1 – Why have Energy Management Systems moved to Chapter 1?1 Question
- 1.20130.2 – What are the New Listing Requirements for Energy Management Equipment?
- 1.21130.2 – What are the New Listing Requirements for Energy Management Equipment?1 Question
- 1.22130.60 – How must Power Control Systems (PCS) handle malfunctions under the 2026 NEC?
- 1.23130.60 – How must Power Control Systems (PCS) handle malfunctions under the 2026 NEC?1 Question
- 1.24130.70 – How Must Power Control System (PCS) Settings Be Configured?
- 1.25130.70 – How Must Power Control System (PCS) Settings Be Configured?1 Question
- 1.26210.11 – Are Small Appliance Circuits Now Strictly Dedicated?
- 1.27210.11 – Are Small Appliance Circuits Now Strictly Dedicated?1 Question
- 1.28210.12 – AFCI Updates: Welding Exceptions & Retrofit Flexibility
- 1.29210.12 – AFCI Updates: Welding Exceptions & Retrofit Flexibility1 Question
- 1.30210.14 – Where did the Specific-Purpose Branch Circuits Table go in the 2026 NEC?
- 1.31210.14 – Where did the Specific-Purpose Branch Circuits Table go in the 2026 NEC?1 Question
- 1.32210.17 – Do Dormitories With Cooking Provisions Require Dwelling Unit Branch Circuits?
- 1.33210.17 – Do Dormitories With Cooking Provisions Require Dwelling Unit Branch Circuits?1 Question
- 1.34210.19 – Where Did the Calculation Tables Go? Sizing Branch-Circuit Conductors
- 1.35210.19 – Where Did the Calculation Tables Go? Sizing Branch-Circuit Conductors1 Question
- 1.36210.52 – Where Can Receptacles Go? New Restrictions for Islands and Cabinets
- 1.37210.52 – Where Can Receptacles Go? New Restrictions for Islands and Cabinets1 Question
- 1.38210.8 – Updates to GFCI Requirements: Outdoor Outlets, HVAC, and High Frequencies
- 1.39210.8 – Updates to GFCI Requirements: Outdoor Outlets, HVAC, and High Frequencies1 Question
- 1.40215.18 – New SPD Requirements for Emergency Service Sleeping Quarters
- 1.41215.18 – New SPD Requirements for Emergency Service Sleeping Quarters1 Question
- 1.42240.4 – How Has Small Conductor Protection and OCPD Terminology Changed?
- 1.43240.4 – How Has Small Conductor Protection and OCPD Terminology Changed?1 Question
- 1.44240.67 – How has Arc Energy Reduction for Large Fuses been Updated?
- 1.45240.67 – How has Arc Energy Reduction for Large Fuses been Updated?1 Question
- 1.46240.87 – How Has Arc Energy Reduction Terminology Updated?
- 1.47240.87 – How Has Arc Energy Reduction Terminology Updated?1 Question
- 1.48242.1 – How Has the Scope of Article 242 Changed for DC Systems?
- 1.49242.1 – How Has the Scope of Article 242 Changed for DC Systems?1 Question
- 1.50242.54 – How have cross-references for surge arrester interconnections changed?
- 1.51242.54 – How have cross-references for surge arrester interconnections changed?1 Question
- 1.52250.122 – Restructured Rules for EGC Sizing and Citations
- 1.53250.122 – Restructured Rules for EGC Sizing and Citations1 Question
- 1.54268.31 – New Requirements for Service Conductor Sizing and Ampacity
- 1.55268.31 – New Requirements for Service Conductor Sizing and Ampacity1 Question
- 1.56268.42 – How are Medium Voltage Service Conductors Sized in the 2026 NEC?
- 1.57268.42 – How are Medium Voltage Service Conductors Sized in the 2026 NEC?1 Question
- 1.58270.122 – New Article 270: Sizing EGCs for Medium Voltage Systems
- 1.59270.122 – New Article 270: Sizing EGCs for Medium Voltage Systems1 Question
- 1.60270.166 – How are DC Grounding Electrode Conductors Sized in the 2026 NEC?
- 1.61270.166 – How are DC Grounding Electrode Conductors Sized in the 2026 NEC?1 Question
- 1.62270.66 – How Do You Size AC Grounding Electrode Conductors for Systems Over 1000V AC/1500V DC in 2026?
- 1.63270.66 – How Do You Size AC Grounding Electrode Conductors for Systems Over 1000V AC/1500V DC in 2026?1 Question
- 1.64310.16 – New Ampacities for Small Conductors and Copper-Clad Aluminum
- 1.65310.16 – New Ampacities for Small Conductors and Copper-Clad Aluminum1 Question
- 1.66406.46 – Have Switch Ratings Moved to Article 406?
- 1.67406.46 – Have Switch Ratings Moved to Article 406?1 Question
- 1.68422.11 – New Acronyms and Relocated Tables for Appliance Protection
- 1.69422.11 – New Acronyms and Relocated Tables for Appliance Protection1 Question
- 1.70525.24 – How has GFCI Protection for Carnivals and Fairs Changed?
- 1.71525.24 – How has GFCI Protection for Carnivals and Fairs Changed?1 Question
- 1.72555.35 – New Fire Pump Rules and GFPE Testing in Marinas
- 1.73555.35 – New Fire Pump Rules and GFPE Testing in Marinas1 Question
- 1.74625.42 – How has EVSE Load Management changed in the 2026 NEC?
- 1.75625.42 – How has EVSE Load Management changed in the 2026 NEC?1 Question
- 1.76680.10 – How has NEC 680.10 changed for Pool Heaters and Heat Pumps?
- 1.77680.10 – How has NEC 680.10 changed for Pool Heaters and Heat Pumps?1 Question
- 1.78680.75 – Does the 2026 NEC Change GFCI Rules for Hydromassage Tubs?
- 1.79680.75 – Does the 2026 NEC Change GFCI Rules for Hydromassage Tubs?1 Question
- 1.80700.32 – When is Re-Evaluation Required for Selective Coordination?
- 1.81700.32 – When is Re-Evaluation Required for Selective Coordination?1 Question
- 1.82700.5 – Where Did the Transfer Equipment Rules Go? (Restructuring 700.5)
- 1.83700.5 – Where Did the Transfer Equipment Rules Go? (Restructuring 700.5)1 Question
- 1.84701.5 – NEC 701.5: Capacity, Rating, and the Shift from Transfer Equipment
- 1.85701.5 – NEC 701.5: Capacity, Rating, and the Shift from Transfer Equipment1 Question
- 1.86722.171 – Where Did Fire Alarm Wiring Methods Go? New Section 722.171
- 1.87722.171 – Where Did Fire Alarm Wiring Methods Go? New Section 722.1711 Question
- 1.8890.2 – How Has the Scope of the NEC Been Reorganized for 2026?
- 1.8990.2 – How Has the Scope of the NEC Been Reorganized for 2026?1 Question
- NEC 2026: Grounding, Bonding, and Services88
- 2.1225.30 – Can Multiple Feeders Supply One Building? (2026 Update)
- 2.2225.30 – Can Multiple Feeders Supply One Building? (2026 Update)1 Question
- 2.3225.41 – How Has the Emergency Disconnect Rule Changed for 2026?
- 2.4225.41 – How Has the Emergency Disconnect Rule Changed for 2026?1 Question
- 2.5230.2 – New Listing Requirements for Service Equipment
- 2.6230.2 – New Listing Requirements for Service Equipment1 Question
- 2.7230.4 – Where Did “Number of Services” Go? (Relocated to 230.4)
- 2.8230.4 – Where Did “Number of Services” Go? (Relocated to 230.4)1 Question
- 2.9230.5 – Can Service Conductors Pass Through Another Building?
- 2.10230.5 – Can Service Conductors Pass Through Another Building?1 Question
- 2.11230.67 – Are Emergency Responder Sleeping Quarters Now Required to Have Surge Protection?
- 2.12230.67 – Are Emergency Responder Sleeping Quarters Now Required to Have Surge Protection?1 Question
- 2.13230.68 – Are Meter Sockets Considered Service Equipment in the 2026 NEC?
- 2.14230.68 – Are Meter Sockets Considered Service Equipment in the 2026 NEC?1 Question
- 2.15230.70 – Mandatory Outdoor Service Disconnects for Dwellings
- 2.16230.70 – Mandatory Outdoor Service Disconnects for Dwellings1 Question
- 2.17230.71 – How Many Service Disconnects? 2026 Updates to 230.71
- 2.18230.71 – How Many Service Disconnects? 2026 Updates to 230.711 Question
- 2.19230.82 – New Equipment Allowed on the Supply Side of Service Disconnects
- 2.20230.82 – New Equipment Allowed on the Supply Side of Service Disconnects1 Question
- 2.21230.95 – New GFPE Requirements for DC Services
- 2.22230.95 – New GFPE Requirements for DC Services1 Question
- 2.23250.109 – How Do You Bond Metal Raceways in Nonmetallic Boxes?
- 2.24250.109 – How Do You Bond Metal Raceways in Nonmetallic Boxes?1 Question
- 2.25250.119 – Are Yellow Wires with Green Stripes Allowed for Hot Circuits?
- 2.26250.119 – Are Yellow Wires with Green Stripes Allowed for Hot Circuits?1 Question
- 2.27250.146 – How Has the Structure for Receptacle Grounding Changed?
- 2.28250.146 – How Has the Structure for Receptacle Grounding Changed?1 Question
- 2.29250.30 – Grounding Separately Derived Systems: Terminology and References
- 2.30250.30 – Grounding Separately Derived Systems: Terminology and References1 Question
- 2.31250.4 – Performance Requirements: Clarifying Grounding and Bonding
- 2.32250.4 – Performance Requirements: Clarifying Grounding and Bonding1 Question
- 2.33250.64 – Can You Run a GEC Through a Mounting Hole? (2026 Update)
- 2.34250.64 – Can You Run a GEC Through a Mounting Hole? (2026 Update)1 Question
- 2.35250.68 – Refining Grounding Electrode Connections
- 2.36250.68 – Refining Grounding Electrode Connections1 Question
- 2.37250.94 – Ensuring Verified Safety: New Listing Requirements for Intersystem Bonding
- 2.38250.94 – Ensuring Verified Safety: New Listing Requirements for Intersystem Bonding1 Question
- 2.39268.1 – Where Did Medium Voltage Services Go in the 2026 NEC?
- 2.40268.1 – Where Did Medium Voltage Services Go in the 2026 NEC?1 Question
- 2.41268.2 – Is Listing Now Mandatory for All Article 268 Service Equipment?
- 2.42268.2 – Is Listing Now Mandatory for All Article 268 Service Equipment?1 Question
- 2.43268.40 – New Location, Same Critical Rules: Limiting Service-Entrance Conductor Sets
- 2.44268.40 – New Location, Same Critical Rules: Limiting Service-Entrance Conductor Sets1 Question
- 2.45268.70 – Where Must High-Voltage Service Disconnects Be Located in the 2026 NEC?
- 2.46268.70 – Where Must High-Voltage Service Disconnects Be Located in the 2026 NEC?1 Question
- 2.47270.102 – How are Bonding Jumpers Sized and Installed for Systems Over 1000V AC / 1500V DC in the 2026 NEC?
- 2.48270.102 – How are Bonding Jumpers Sized and Installed for Systems Over 1000V AC / 1500V DC in the 2026 NEC?1 Question
- 2.49270.104 – How is Bonding of Piping and Structural Metal Handled for Systems Over 1000V AC / 1500V DC in the 2026 NEC?
- 2.50270.104 – How is Bonding of Piping and Structural Metal Handled for Systems Over 1000V AC / 1500V DC in the 2026 NEC?1 Question
- 2.51270.115 – Relocation of Grounding Rules for Portable Equipment on Systems Over 1000V AC / 1500V DC
- 2.52270.115 – Relocation of Grounding Rules for Portable Equipment on Systems Over 1000V AC / 1500V DC1 Question
- 2.53270.118 – Where are Equipment Grounding Conductors Defined for Systems Over 1000V AC / 1500V DC in the 2026 NEC?
- 2.54270.118 – Where are Equipment Grounding Conductors Defined for Systems Over 1000V AC / 1500V DC in the 2026 NEC?1 Question
- 2.55270.119 – New Article 270: EGC Identification Rules for Systems Over 1000V AC / 1500V DC
- 2.56270.119 – New Article 270: EGC Identification Rules for Systems Over 1000V AC / 1500V DC1 Question
- 2.57270.120 – How are Equipment Grounding Conductors Installed for Systems Over 1000V AC / 1500V DC in 2026?
- 2.58270.120 – How are Equipment Grounding Conductors Installed for Systems Over 1000V AC / 1500V DC in 2026?1 Question
- 2.59270.14 – Where Did Substation Fence Grounding Go? (Relocation & Updates)
- 2.60270.14 – Where Did Substation Fence Grounding Go? (Relocation & Updates)1 Question
- 2.61270.24 – Relocated Requirements: Grounding Service-Supplied AC Systems Over 1000V AC
- 2.62270.24 – Relocated Requirements: Grounding Service-Supplied AC Systems Over 1000V AC1 Question
- 2.63270.27 – Relocation of Medium Voltage Grounding Rules and New Exceptions
- 2.64270.27 – Relocation of Medium Voltage Grounding Rules and New Exceptions1 Question
- 2.65270.28 – How are Main and System Bonding Jumpers Regulated for Systems Over 1000V AC / 1500V DC in the 2026 NEC?
- 2.66270.28 – How are Main and System Bonding Jumpers Regulated for Systems Over 1000V AC / 1500V DC in the 2026 NEC?1 Question
- 2.67270.30 – Where Did Transformer Bonding Go? Introduction to Section 270.30 for Systems Over 1000V AC / 1500V DC
- 2.68270.30 – Where Did Transformer Bonding Go? Introduction to Section 270.30 for Systems Over 1000V AC / 1500V DC1 Question
- 2.69270.32 – Grounding Requirements for Separate Buildings for Systems Over 1000V AC / 1500V DC (New Section 270.32)
- 2.70270.32 – Grounding Requirements for Separate Buildings for Systems Over 1000V AC / 1500V DC (New Section 270.32)1 Question
- 2.71270.34 – When Do Portable Generators Require a Ground Rod for Systems Over 1000V AC / 1500V DC?
- 2.72270.34 – When Do Portable Generators Require a Ground Rod for Systems Over 1000V AC / 1500V DC?1 Question
- 2.73270.36 – New Location and Rules for Impedance Grounded Systems Over 1000V AC / 1500V DC
- 2.74270.36 – New Location and Rules for Impedance Grounded Systems Over 1000V AC / 1500V DC1 Question
- 2.75270.4 – Where Did the General Grounding Requirements Go (for systems over 1000vac/1500vdc) in 2026?
- 2.76270.4 – Where Did the General Grounding Requirements Go (for systems over 1000vac/1500vdc) in 2026?1 Question
- 2.77270.52 – Where Did Grounding Electrodes Go? Introduction to Section 270.52 for Systems Over 1000V AC / 1500V DC
- 2.78270.52 – Where Did Grounding Electrodes Go? Introduction to Section 270.52 for Systems Over 1000V AC / 1500V DC1 Question
- 2.79270.53 – New Location for Grounding Electrode System Installation Rules for systems over 1000vac/1500vdc
- 2.80270.53 – New Location for Grounding Electrode System Installation Rules for systems over 1000vac/1500vdc1 Question
- 2.81270.6 – How Do I Handle Objectionable Current in the 2026 NEC for systems over 1000vac/1500vdc?
- 2.82270.6 – How Do I Handle Objectionable Current in the 2026 NEC for systems over 1000vac/1500vdc?1 Question
- 2.83270.64 – Where are Grounding Electrode Conductor Rules for systems over 1000vac/1500vdc in 2026 ?
- 2.84270.64 – Where are Grounding Electrode Conductor Rules for systems over 1000vac/1500vdc in 2026 ?1 Question
- 2.85270.68 – Where Did Grounding Connections Go for system over 1000vac/1500vdc? New Section 270.68
- 2.86270.68 – Where Did Grounding Connections Go for system over 1000vac/1500vdc? New Section 270.681 Question
- 2.87270.94 – Where Are Intersystem Bonding Requirements Located for Systems Over 1000V AC / 1500V DC in the 2026 NEC?
- 2.88270.94 – Where Are Intersystem Bonding Requirements Located for Systems Over 1000V AC / 1500V DC in the 2026 NEC?1 Question
- NEC 2026: Wiring Methods and Equipment88
- 3.1300.13 – Major Relocation: Securing and Supporting Moves to Section 300.13
- 3.2300.13 – Major Relocation: Securing and Supporting Moves to Section 300.131 Question
- 3.3300.24 – Is the 360-Degree Bend Limit Now a General Requirement?
- 3.4300.24 – Is the 360-Degree Bend Limit Now a General Requirement?1 Question
- 3.5300.4 – Where Did the Nail Plates Go? The Repurposing of Section 300.4
- 3.6300.4 – Where Did the Nail Plates Go? The Repurposing of Section 300.41 Question
- 3.7300.5 – Major Restructuring: Section 300.5 is Now “Conductors”
- 3.8300.5 – Major Restructuring: Section 300.5 is Now “Conductors”1 Question
- 3.9300.6 – Where Did the Physical Damage Rules Go? (Section 300.6)
- 3.10300.6 – Where Did the Physical Damage Rules Go? (Section 300.6)1 Question
- 3.11300.9 – Managing Temperature Changes: Condensation and Expansion
- 3.12300.9 – Managing Temperature Changes: Condensation and Expansion1 Question
- 3.13305.14 – Where Did the Physical Damage Protection Rules Go? (Systems over 1000VAC/1500VDC)
- 3.14305.14 – Where Did the Physical Damage Protection Rules Go? (Systems over 1000VAC/1500VDC)1 Question
- 3.15305.16 – Where Did the Corrosion Protection Rules Go? (Systems over 1000VAC/1500VDC)
- 3.16305.16 – Where Did the Corrosion Protection Rules Go? (Systems over 1000VAC/1500VDC)1 Question
- 3.17305.17 – How are Temperature Changes Handled in the 2026 NEC? (Systems over 1000VAC/1500VDC)
- 3.18305.17 – How are Temperature Changes Handled in the 2026 NEC? (Systems over 1000VAC/1500VDC)1 Question
- 3.19305.21 – New General Requirements for Securing and Supporting Wiring Methods (Systems over 1000VAC/1500VDC)
- 3.20305.21 – New General Requirements for Securing and Supporting Wiring Methods (Systems over 1000VAC/1500VDC)1 Question
- 3.21305.29 – Where Did Vertical Raceway Supports Go? (New Section 305.29)
- 3.22305.29 – Where Did Vertical Raceway Supports Go? (New Section 305.29)1 Question
- 3.23305.32 – Wiring in Ducts and Plenums (Section 305.32) (Systems over 1000VAC/1500VDC)
- 3.24305.32 – Wiring in Ducts and Plenums (Section 305.32) (Systems over 1000VAC/1500VDC)1 Question
- 3.25310.5 – New Minimum Conductor Sizes and Section Relocation
- 3.26310.5 – New Minimum Conductor Sizes and Section Relocation1 Question
- 3.27312.11 – Where did the Rules for Splices in Switch Enclosures Go?
- 3.28312.11 – Where did the Rules for Splices in Switch Enclosures Go?1 Question
- 3.29314.27 – Outlet Box Support and Fan Box Locations: 2026 Revisions
- 3.30314.27 – Outlet Box Support and Fan Box Locations: 2026 Revisions1 Question
- 3.31342.30 – Updates to IMC Securing and Supporting References
- 3.32342.30 – Updates to IMC Securing and Supporting References1 Question
- 3.33400.10 – Clarifying References for Flexible Cord Requirements
- 3.34400.10 – Clarifying References for Flexible Cord Requirements1 Question
- 3.35402.13 – Where Did Table 402.3 Go? New Location for Fixture Wire Types
- 3.36402.13 – Where Did Table 402.3 Go? New Location for Fixture Wire Types1 Question
- 3.37404.2 – Where Did the “Neutral at the Switch” Rule Go? (New Listing Requirements)
- 3.38404.2 – Where Did the “Neutral at the Switch” Rule Go? (New Listing Requirements)1 Question
- 3.39406.12 – Where Did General Installation Requirements for receptacles, cord connectors, and attachment plugs Go?
- 3.40406.12 – Where Did General Installation Requirements for receptacles, cord connectors, and attachment plugs Go?1 Question
- 3.41406.14 – Where Did Receptacle Mounting Rules Go in the 2026 NEC?
- 3.42406.14 – Where Did Receptacle Mounting Rules Go in the 2026 NEC?1 Question
- 3.43406.16 – Did Receptacle Faceplate Rules Move?
- 3.44406.16 – Did Receptacle Faceplate Rules Move?1 Question
- 3.45406.18 – Where did the rules for Attachment Plugs and Connectors go in 2026?
- 3.46406.18 – Where did the rules for Attachment Plugs and Connectors go in 2026?1 Question
- 3.47406.19 – Where Did Grounding-Type Receptacle Rules Go? (Relocation to 406.19)
- 3.48406.19 – Where Did Grounding-Type Receptacle Rules Go? (Relocation to 406.19)1 Question
- 3.49406.26 – Where are Tamper-Resistant Receptacles Now Required?
- 3.50406.26 – Where are Tamper-Resistant Receptacles Now Required?1 Question
- 3.51406.28 – Where Did Single-Pole Separable Connectors Go? Understanding New Section 406.28
- 3.52406.28 – Where Did Single-Pole Separable Connectors Go? Understanding New Section 406.281 Question
- 3.53406.30 – Where Did the Neutral Rule Go? Relocation of Switch Connections
- 3.54406.30 – Where Did the Neutral Rule Go? Relocation of Switch Connections1 Question
- 3.55406.38 – Where Did the Switch Grouping Rule Go? Understanding New Section 406.38
- 3.56406.38 – Where Did the Switch Grouping Rule Go? Understanding New Section 406.381 Question
- 3.57406.40 – Switch Faceplates Relocated and Expanded to Include Dimmers and Control Switches
- 3.58406.40 – Switch Faceplates Relocated and Expanded to Include Dimmers and Control Switches1 Question
- 3.59406.9 – 406.9 includes switches now?
- 3.60406.9 – 406.9 includes switches now?1 Question
- 3.61408.10 – Where Did the Busbar Rules Go? A Move to 408.10
- 3.62408.10 – Where Did the Busbar Rules Go? A Move to 408.101 Question
- 3.63408.3 – New Rules for Reconditioned Equipment (Section 408.3)
- 3.64408.3 – New Rules for Reconditioned Equipment (Section 408.3)1 Question
- 3.65409.110 – SCCR Visibility and Marking Updates for Industrial Control Panels
- 3.66409.110 – SCCR Visibility and Marking Updates for Industrial Control Panels1 Question
- 3.67410.116 – Recessed Luminaire Clearances and Fire-Rated Installations
- 3.68410.116 – Recessed Luminaire Clearances and Fire-Rated Installations1 Question
- 3.69410.64 – Can Luminaires Be Used as Raceways?
- 3.70410.64 – Can Luminaires Be Used as Raceways?1 Question
- 3.71424.19 – How Have Disconnecting Means for Space Heating Changed?
- 3.72424.19 – How Have Disconnecting Means for Space Heating Changed?1 Question
- 3.73426.60 – How Does the 2026 NEC Address Conductive Pavement Heating?
- 3.74426.60 – How Does the 2026 NEC Address Conductive Pavement Heating?1 Question
- 3.75426.62 – Where are Conductive Pavement Heating Systems Prohibited?
- 3.76426.62 – Where are Conductive Pavement Heating Systems Prohibited?1 Question
- 3.77625.2 – How Have Listing Requirements for EV Equipment Changed?
- 3.78625.2 – How Have Listing Requirements for EV Equipment Changed?1 Question
- 3.79625.40 – Did the Exception for EV Branch Circuits Change in 2026?
- 3.80625.40 – Did the Exception for EV Branch Circuits Change in 2026?1 Question
- 3.81625.43 – Emergency Shutoffs and Expanded Disconnect Rules for EVSE
- 3.82625.43 – Emergency Shutoffs and Expanded Disconnect Rules for EVSE1 Question
- 3.83625.44 – New Plug Ratings and Voltage Options for EV Chargers
- 3.84625.44 – New Plug Ratings and Voltage Options for EV Chargers1 Question
- 3.85625.5 – Are You Labeling EVSE Correctly Under the New 2026 Rules?
- 3.86625.5 – Are You Labeling EVSE Correctly Under the New 2026 Rules?1 Question
- 3.87706.31 – Did the 2026 NEC Remove the Current-Limiting Requirement for ESS?
- 3.88706.31 – Did the 2026 NEC Remove the Current-Limiting Requirement for ESS?1 Question
- NEC 2026: Special Conditions40
- 4.1500.30 – How Does the New Section 500.30 Standardize Bonding in Hazardous Locations?
- 4.2500.30 – How Does the New Section 500.30 Standardize Bonding in Hazardous Locations?1 Question
- 4.3500.7 – Does Gas Detection Replace Purge Cycles in Hazardous Locations?
- 4.4500.7 – Does Gas Detection Replace Purge Cycles in Hazardous Locations?1 Question
- 4.5500.8 – Clarifying Equipment vs. Installation in Hazardous Locations
- 4.6500.8 – Clarifying Equipment vs. Installation in Hazardous Locations1 Question
- 4.7501.10 – How 501.10 Transformed Wiring Methods into Tables
- 4.8501.10 – How 501.10 Transformed Wiring Methods into Tables1 Question
- 4.9501.15 – Clarifying Boundary Seals and Cable Types in Hazardous Locations
- 4.10501.15 – Clarifying Boundary Seals and Cable Types in Hazardous Locations1 Question
- 4.11511.5 – Where did the Area Classification rules for Commercial Garages go?
- 4.12511.5 – Where did the Area Classification rules for Commercial Garages go?1 Question
- 4.13511.6 – How Have Commercial Garage Rules Changed for 2026?
- 4.14511.6 – How Have Commercial Garage Rules Changed for 2026?1 Question
- 4.15512.5 – How are Hazardous Locations Classified for Cannabis Oil Equipment?
- 4.16512.5 – How are Hazardous Locations Classified for Cannabis Oil Equipment?1 Question
- 4.17514.5 – Where Did Classification Go? Relocation of Hazardous Locations
- 4.18514.5 – Where Did Classification Go? Relocation of Hazardous Locations1 Question
- 4.19515.5 – Relocation of Classification Rules for Bulk Storage Plants
- 4.20515.5 – Relocation of Classification Rules for Bulk Storage Plants1 Question
- 4.21516.8 – Spray Area Safety: Renumbering and Static Grounding Requirements
- 4.22516.8 – Spray Area Safety: Renumbering and Static Grounding Requirements1 Question
- 4.23516.9 – New Location for Wiring Rules Above Spray Areas
- 4.24516.9 – New Location for Wiring Rules Above Spray Areas1 Question
- 4.25590.4 – Where Did the Rules Go? Section 590.4 Completely Restructured
- 4.26590.4 – Where Did the Rules Go? Section 590.4 Completely Restructured1 Question
- 4.27590.6 – Major Restructuring: General Rules Move to 590.6
- 4.28590.6 – Major Restructuring: General Rules Move to 590.61 Question
- 4.29625.17 – EVSE Cords: “Hand Fastened” Terminology and Ampacity Clarity
- 4.30625.17 – EVSE Cords: “Hand Fastened” Terminology and Ampacity Clarity1 Question
- 4.31680.2 – Is Listing Now Mandatory for All Pool and Spa Equipment?
- 4.32680.2 – Is Listing Now Mandatory for All Pool and Spa Equipment?1 Question
- 4.33680.23 – Clarified Bonding Requirements for Wet-Niche Luminaires
- 4.34680.23 – Clarified Bonding Requirements for Wet-Niche Luminaires1 Question
- 4.35680.26 – New Materials and Listing Extensions for Pool Bonding
- 4.36680.26 – New Materials and Listing Extensions for Pool Bonding1 Question
- 4.37680.42 – How have the references in Section 680.42 changed for 2026?
- 4.38680.42 – How have the references in Section 680.42 changed for 2026?1 Question
- 4.39680.5 – How Have GFCI Requirements for 3-Phase Pool Equipment Changed?
- 4.40680.5 – How Have GFCI Requirements for 3-Phase Pool Equipment Changed?1 Question
- 2024 NFPA 70E: Electrical Safety80
- 5.1Understanding the Purpose and Scope of NFPA 70E 2024 (Article 90)
- 5.2Quiz – Understanding the Purpose and Scope of NFPA 70E 2024 (Article 90)1 Question
- 5.3Key Definitions for Electrical Safety (Article 100)
- 5.4Quiz – Key Definitions for Electrical Safety (Article 100)1 Question
- 5.5Employer and Employee Responsibilities (Article 105)
- 5.6Quiz – Employer and Employee Responsibilities (Article 105)1 Question
- 5.7Core Elements of the Electrical Safety Program (ESP) [Section 110.2 & Section 110.3]
- 5.8Quiz – Core Elements of the Electrical Safety Program (ESP)1 Question
- 5.9Job Safety Planning and Job Briefings [Subdivision 110.3(I)]
- 5.10Quiz – Job Safety Planning and Job Briefings1 Question
- 5.11Training Requirements for Qualified and Unqualified Persons [Subdivision 110.4(A)]
- 5.12Quiz – Training Requirements for Qualified and Unqualified Persons1 Question
- 5.13Safe Selection and Use of Test Instruments [Section 110.6]
- 5.14Quiz – Safe Selection and Use of Test Instruments1 Question
- 5.15The Priority of an Electrically Safe Work Condition [Subdivision 110.2(B)]
- 5.16Quiz – The Priority of an Electrically Safe Work Condition1 Question
- 5.17Principles of a Lockout/Tagout (LOTO) Program [Section 120.3]
- 5.18Quiz – Principles of a Lockout/Tagout (LOTO) Program1 Question
- 5.19Simple vs. Complex Lockout/Tagout Procedures [Section 120.5]
- 5.20Quiz – Simple vs. Complex Lockout/Tagout Procedures1 Question
- 5.21The Step-by-Step De-energization Process [Section 120.6]
- 5.22Quiz – The Step-by-Step De-energization Process1 Question
- 5.23Verifying the Absence of Voltage [Subdivision 120.6(7)]
- 5.24Quiz – Verifying the Absence of Voltage1 Question
- 5.25Justifying Energized Work and the Energized Electrical Work Permit (EEWP)
- 5.26Quiz – Justifying Energized Work and the Energized Electrical Work Permit (EEWP)1 Question
- 5.27Performing an Electric Shock Risk Assessment [Section 130.4]
- 5.28Quiz – Performing a Shock Risk Assessment1 Question
- 5.29Limited and Restricted Approach Boundaries [Subdivision 130.4(E)]
- 5.30Quiz – Limited and Restricted Approach Boundaries1 Question
- 5.31Performing an Arc Flash Risk Assessment [Section 130.5]
- 5.32Quiz – Performing an Arc Flash Risk Assessment1 Question
- 5.33Determining the Arc Flash Boundary [Section 130.7]
- 5.34Quiz – Determining the Arc Flash Boundary1 Question
- 5.35Methods for Selecting Arc Flash PPE [Subdivision 130.5(F)]
- 5.36Quiz – Methods for Selecting Arc Flash PPE1 Question
- 5.37Understanding Arc Flash PPE Categories [Table 130.7(C)(15)(c)]
- 5.38Quiz – Understanding Arc Flash PPE Categories1 Question
- 5.39Requirements for Arc-Rated Clothing and Underlayers [Subdivision 130.7(C)(9)(c)]
- 5.40Quiz – Requirements for Arc-Rated Clothing and Underlayers1 Question
- 5.41Head, Face, Hand, and Foot Protection [Table 130.7(C)(15)(c)]
- 5.42Quiz – Head, Face, Hand, and Foot Protection1 Question
- 5.43General Requirements for Safety-Related Maintenance [Article 205]
- 5.44Quiz – General Requirements for Safety-Related Maintenance1 Question
- 5.45Maintenance of Switchgear, Panelboards, and MCCs [Article 210]
- 5.46Quiz – Maintenance of Switchgear, Panelboards, and MCCs1 Question
- 5.47Maintenance of Fuses and Circuit Breakers [Article 225]
- 5.48Quiz – Maintenance of Fuses and Circuit Breakers1 Question
- 5.49Safety Practices for Batteries and Battery Rooms [Article 320]
- 5.50Quiz – Safety Practices for Batteries and Battery Rooms1 Question
- 5.51Overview of the NFPA 70E Informative Annexes
- 5.52Quiz – Overview of the NFPA 70E Informative Annexes1 Question
- 5.53Defining and Using the Arc Flash Boundary (Subdevision130.5(E))
- 5.54Quiz – Defining and Using the Arc Flash Boundary (Subdivision 130.5(E))1 Question
- 5.55PPE Selection: Incident Energy Analysis Method (Subdivision130.5(G))
- 5.56Quiz – PPE Selection: Incident Energy Analysis Method (Subdivision130.5(G))1 Question
- 5.57PPE Selection: Arc Flash PPE Category Method (Subdivision130.7(C)(15))
- 5.58Quiz – PPE Selection: Arc Flash PPE Category Method (Subdivision 130.7(C)(15))1 Question
- 5.59Using the PPE Category Tables for AC Systems (Table 130.7(C)(15)(a))
- 5.60Quiz – Using the PPE Category Tables for AC Systems (Table 130.7(C)(15)(a))1 Question
- 5.61Using the PPE Category Tables for DC Systems (Table 130.7(C)(15)(b))
- 5.62Quiz – Using the PPE Category Tables for DC Systems (Table 130.7(C)(15)(b))1 Question
- 5.63Requirements for Arc-Rated and Underlayer Clothing (Subdivision 130.7(C))
- 5.64Quiz – Requirements for Arc-Rated Clothing and Underlayers1 Question
- 5.65Personal Protective Equipment: Head, Face, Hand, and Foot Protection (Section 130.7)
- 5.66Quiz – Personal Protective Equipment: Head, Face, Hand, and Foot Protection (Section 130.7)1 Question
- 5.67Care, Inspection, and Maintenance of PPE (Subdivision 130.7(B))
- 5.68Quiz – Care, Inspection, and Maintenance of PPE (Subdivision 130.7(B))1 Question
- 5.69Barricades, Attendants, and Alerting Techniques (Subdivision 130.8(O))
- 5.70Quiz – Barricades, Attendants, and Alerting Techniques (Subdivision 130.8(O))1 Question
- 5.71The Importance of Safety-Related Maintenance (Article 200, 205)
- 5.72Quiz – The Importance of Safety-Related Maintenance (Article 200, 205)1 Question
- 5.73Maintenance of Switchgear, Panelboards, and Motor Control Centers (Article 210)
- 5.74Quiz – Maintenance of Switchgear, Panelboards, and Motor Control Centers (Article 210)1 Question
- 5.75Maintenance of Fuses and Circuit Breakers (Article 225)
- 5.76Quiz – Maintenance of Fuses and Circuit Breakers (Article 225)1 Question
- 5.77Maintenance of Rotating Equipment and Controller Equipment (Article 220,230)
- 5.78Quiz – Maintenance of Rotating Equipment and Controller Equipment (Article 220,230)1 Question
- 5.79General Safety Requirements for Special Equipment (Article 300)
- 5.80Quiz – General Safety Requirements for Special Equipment (Article 300)1 Question