This 8-hour comprehensive online course offers a detailed exploration of the foundational changes and specialized safety enhancements introduced in the 2026 National Electrical Code (NEC). The curriculum begins with a deep dive into equipment and general-use requirements, covering critical updates to receptacle replacements, the installation of USB-integrated faceplates, and the strict new regulations for receptacles near bathtub and shower spaces. Participants will also examine hazardous location classifications, including specialized requirements for commercial garages and the newly addressed equipment standards for cannabis oil extraction facilities.
The training further explores technical advancements in specialized systems, providing practical instruction on Electric Vehicle (EV) power transfer systems, “island mode” capabilities for power export, and updated GFCI protection rules for elevators and swimming pools. A significant portion of the course is dedicated to emergency and interconnected power sources, where licensees will learn to apply selective coordination for emergency lighting and navigate the commissioning of Energy Storage Systems (ESS). Finally, the course introduces the new standards for Class 4 power systems and updated communications circuit rules, ensuring that professionals are equipped to implement these rigorous 2026 standards in residential, commercial, and industrial environments
Course Features
- Lectures 61
- Quizzes 60
- Duration 52 weeks
- Skill level All levels
- Language English
- Students 0
- Certificate Yes
- Assessments Yes
- 5 Sections
- 61 Lessons
- NEC Courses Article 400 Series13
- 1.1Course OrientationCopy
- 1.2440.8 Single Machine and LocationCopy
- 1.3440.8 Single Machine and LocationCopy1 Question
- 1.4445.19 Emergency Shutdown of Prime Mover Copy
- 1.5445.19 Emergency Shutdown of Prime MoverCopy1 Question
- 1.6470.2 Reconditioned EquipmentCopy
- 1.7470.2 Reconditioned EquipmentCopy1 Question
- 1.8406.4(D) Receptacle ReplacementsCopy
- 1.9406.4(D) Receptacle ReplacementsCopy1 Question
- 1.10406.6(D) Receptacle Faceplate (Cover Plates) With Integral Night Light and/or USB ChargerCopy
- 1.11406.6(D) Receptacle Faceplate (Cover Plates) With Integral Night Light and/or USB ChargerCopy1 Question
- 1.12406.9 (C) Bathtub and Shower SpaceCopy
- 1.13406.9 (C) Bathtub and Shower SpaceCopy1 Question
- NEC Courses Article 500 Series34
- 2.1501.30 Grounding and BondingCopy
- 2.2501.30 Grounding and BondingCopy1 Question
- 2.3502.30 Grounding and BondingCopy
- 2.4502.30 Grounding and BondingCopy1 Question
- 2.5511.7(A) Wiring in Spaces Above Hazardous (Classified) LocationsCopy
- 2.6511.7(A) Wiring in Spaces Above Hazardous (Classified) LocationsCopy1 Question
- 2.7512.13 Wiring Installed Above Hazardous (Classified) LocationsCopy
- 2.8512.13 Wiring Installed Above Hazardous (Classified) LocationsCopy1 Question
- 2.9512.20 Equipment and SystemsCopy
- 2.10512.20 Equipment and SystemsCopy1 Question
- 2.11517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care SpacesCopy
- 2.12517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care SpacesCopy1 Question
- 2.13517.14 Panelboard BondingCopy
- 2.14517.14 Panelboard BondingCopy1 Question
- 2.15517.30(B) Power Sources for the EESCopy
- 2.16517.30(B) Power Sources for the EESCopy1 Question
- 2.17518.4 Wiring MethodsCopy
- 2.18518.4 Wiring MethodsCopy1 Question
- 2.19518.5 SupplyCopy
- 2.20518.5 SupplyCopy1 Question
- 2.21547.26 Physical ProtectionCopy
- 2.22547.26 Physical ProtectionCopy1 Question
- 2.23547.44 Equipotential Planes and Bonding of Equipotential PlanesCopy
- 2.24547.44 Equipotential Planes and Bonding of Equipotential PlanesCopy1 Question
- 2.25551.3 Electrical Datum Plane DistancesCopy
- 2.26551.3 Electrical Datum Plane DistancesCopy1 Question
- 2.27551.40 120-Volt or 120/240-Volt, Nominal, SystemsCopy
- 2.28551.40 120-Volt or 120/240-Volt, Nominal, SystemsCopy1 Question
- 2.29555.14 Equipotential Planes and Bonding of Equipotential PlanesCopy
- 2.30555.14 Equipotential Planes and Bonding of Equipotential PlanesCopy1 Question
- 2.31500.5 (D) Classifications of LocationsCopy
- 2.32500.5 (D) Classifications of LocationsCopy1 Question
- 2.33512.3(A) Cannabis Oil Equipment and Systems Other Than Booths Copy
- 2.34512.3(A) Cannabis Oil Equipment and Systems Other Than BoothsCopy1 Question
- NEC Courses Article 600 Series34
- 3.1600.35 – Retrofit KitsCopy
- 3.2600.35 – Retrofit KitsCopy1 Question
- 3.3600.6 – DisconnectsCopy
- 3.4600.6 – DisconnectsCopy1 Question
- 3.5620.36 – Different Systems in One Raceway or Traveling Cable.Copy
- 3.6620.36 – Different Systems in One Raceway or Traveling Cable.Copy1 Question
- 3.7620.6 – GFCI Protection for PersonnelCopy
- 3.8620.6 – GFCI Protection for PersonnelCopy1 Question
- 3.9625.40 Electric Vehicle Branch CircuitCopy
- 3.10625.40 Electric Vehicle Branch CircuitCopy1 Question
- 3.11625.42 RatingCopy
- 3.12625.42 RatingCopy1 Question
- 3.13625.49 – Island ModeCopy
- 3.14625.49 – Island ModeCopy1 Question
- 3.15625.6 – ListedCopy
- 3.16625.6 – ListedCopy1 Question
- 3.17630.8 – Electric WeldersCopy
- 3.18630.8 – Electric WeldersCopy1 Question
- 3.19646.19 – Entrance to and Egress from Working SpaceCopy
- 3.20646.19 – Entrance to and Egress from Working SpaceCopy1 Question
- 3.21680.10 – Pool Water Temperature Conditioning EquipmentCopy
- 3.22680.10 – Pool Water Temperature Conditioning EquipmentCopy1 Question
- 3.23680.12 – Equipment Rooms, Vaults, and PitsCopy
- 3.24680.12 – Equipment Rooms, Vaults, and PitsCopy1 Question
- 3.25680.14 Corrosive EnvironmentsCopy
- 3.26680.14 Corrosive EnvironmentsCopy1 Question
- 3.27680.32 – GFCI and SPGFCI ProtectionCopy
- 3.28680.32 – GFCI and SPGFCI ProtectionCopy1 Question
- 3.29680.44 – GFCI & SPGFCI ProtectionCopy
- 3.30680.44 – GFCI & SPGFCI ProtectionCopy1 Question
- 3.31680.5 – GFCI and SPGFCI ProtectionCopy
- 3.32680.5 – GFCI and SPGFCI ProtectionCopy1 Question
- 3.33690.1 New illustration to help understand PV components Copy
- 3.34690.1 New illustration to help understand PV componentsCopy1 Question
- NEC Courses Article 700 Series34
- 4.1700.11 Wiring, Class-2-Powered Emergency Lighting SystemsCopy
- 4.2700.11 Wiring, Class-2-Powered Emergency Lighting SystemsCopy1 Question
- 4.3700.27 Class 2 Powered Emergency Lighting SystemsCopy
- 4.4700.27 Class 2 Powered Emergency Lighting SystemsCopy1 Question
- 4.5700.32 Selective CoordinationCopy
- 4.6700.32 Selective CoordinationCopy1 Question
- 4.7700.4 Capacity and RatingCopy
- 4.8700.4 Capacity and RatingCopy1 Question
- 4.9701.10 Wiring Legally Required Standby SystemsCopy
- 4.10701.10 Wiring Legally Required Standby SystemsCopy1 Question
- 4.11702.12 Outdoor Generator SetsCopy
- 4.12702.12 Outdoor Generator SetsCopy1 Question
- 4.13702.5 Interconnection or Transfer EquipmentCopy
- 4.14702.5 Interconnection or Transfer EquipmentCopy1 Question
- 4.15705.10 Identification of Power SourcesCopy
- 4.16705.10 Identification of Power SourcesCopy1 Question
- 4.17705.30 Overcurrent ProtectionCopy
- 4.18705.30 Overcurrent ProtectionCopy1 Question
- 4.19705.50 System OperationCopy
- 4.20705.50 System OperationCopy1 Question
- 4.21706.7 Commissioning and MaintenanceCopy
- 4.22706.7 Commissioning and MaintenanceCopy1 Question
- 4.23726.121 Power Sources for Class 4 CircuitsCopy
- 4.24726.121 Power Sources for Class 4 CircuitsCopy1 Question
- 4.25726.122 Class 4 LoadsCopy
- 4.26726.122 Class 4 LoadsCopy1 Question
- 4.27726.124 Class 4 MarkingCopy
- 4.28726.124 Class 4 MarkingCopy1 Question
- 4.29726.130 Terminals and ConnectorsCopy
- 4.30726.130 Terminals and ConnectorsCopy1 Question
- 4.31726.136(E) Enclosures with Single OpeningsCopy
- 4.32726.136(E) Enclosures with Single OpeningsCopy1 Question
- 4.33726.144 AmpacityCopy
- 4.34726.144 AmpacityCopy1 Question
- NEC Courses Article 800 Series6
- 5.1800.133 – Installation of Wires, Cables, Cable Routing Assemblies, and Communications RacewaysCopy
- 5.2800.133 – Installation of Wires, Cables, Cable Routing Assemblies, and Communications RacewaysCopy1 Question
- 5.3800.170 – Plenum Cable TiesCopy
- 5.4800.170 – Plenum Cable TiesCopy1 Question
- 5.5800.179 – Wires and CablesCopy
- 5.6800.179 – Wires and CablesCopy1 Question