Covers changes in the 2026 edition of the National Electrical Code, beginning with Article 110 requirements for available fault current, arc flash and fault current labels, and working space, and with energy management and power control systems in Article 130. Participants then examine arc energy reduction in Article 240, conductor sizing and grounding for systems over 1000 volts AC or 1500 volts DC in Articles 268 and 270, feeders and service disconnects in Articles 225 and 230, and grounding and bonding changes in Article 250.
The course then addresses wiring methods and equipment, including securing and supporting in Article 300, boxes in Article 314, receptacle and switch rules relocated within Article 406, luminaires, pavement heating, electric vehicle supply equipment, and energy storage systems. Later lessons cover bonding, wiring methods and seals in hazardous locations under Articles 500 and 501, commercial garages and spray areas, temporary wiring, and pool and spa bonding and GFCI protection in Article 680. The final section covers North Dakota electrical law and rules: license classes and exemptions, apprentice supervision, examinations, renewal and continuing education, discipline, contracting, and advertising.
Learning objectives
- Identify changes in Articles 110, 130 and 240 for fault current labeling, working space, energy management systems, and arc energy reduction.
- Apply grounding, bonding and service requirements in Articles 225, 230 and 250, and the relocated rules for systems over 1000 volts AC or 1500 volts DC in Articles 268 and 270.
- Locate requirements for wiring methods, receptacles, switches, hazardous locations, temporary wiring, and pools in Articles 300 through 680.
- Describe North Dakota license classes, licensing exemptions, renewal and continuing education requirements, and the duties of a contracting electrician.
Disclosure of proprietary interest. No instructor, subject-matter expert or content author involved in developing or delivering this course holds any financial or ownership interest in any product, instrument, device or material referenced in it, and none receives any royalty, profit share or other consideration from the promotion or endorsement of any product. This course does not endorse any commercial product or service.
Course Features
- Lectures 130
- Quizzes 128
- Duration 52 weeks
- Skill level All levels
- Language English
- Students 7
- Certificate Yes
- Assessments Self
- Format Audio + Text
- 5 Sections
- 130 Lessons
- NEC 2026: Theory and Calculations62
- 1.1Course Orientation
- 1.2Learning Objectives
- 1.3110.10 – How has the focus of Section 110.10 shifted regarding Available Fault Current?
- 1.4110.10 – How has the focus of Section 110.10 shifted regarding Available Fault Current?1 Question
- 1.5110.14 – Are Your Compounds “Identified” or Just “Suitable”?
- 1.6110.14 – Are Your Compounds “Identified” or Just “Suitable”?1 Question
- 1.7110.16 – Arc-Flash Labels: From Generic Warnings to Detailed Markings
- 1.8110.16 – Arc-Flash Labels: From Generic Warnings to Detailed Markings1 Question
- 1.9110.21 – Updating References for Field-Applied Hazard Markings
- 1.10110.21 – Updating References for Field-Applied Hazard Markings1 Question
- 1.11110.24 – How Must Fault Current Labels Be Marked in 2026?
- 1.12110.24 – How Must Fault Current Labels Be Marked in 2026?1 Question
- 1.13110.26 – How Have Working Space Rules Changed for DC Systems and Enclosed Parts?
- 1.14110.26 – How Have Working Space Rules Changed for DC Systems and Enclosed Parts?1 Question
- 1.15110.31 – How have fence clearance requirements changed for High-Voltage DC systems?
- 1.16110.31 – How have fence clearance requirements changed for High-Voltage DC systems?1 Question
- 1.17130.1 – Why have Energy Management Systems moved to Chapter 1?
- 1.18130.1 – Why have Energy Management Systems moved to Chapter 1?1 Question
- 1.19130.2 – What are the New Listing Requirements for Energy Management Equipment?
- 1.20130.2 – What are the New Listing Requirements for Energy Management Equipment?1 Question
- 1.21130.60 – How must Power Control Systems (PCS) handle malfunctions under the 2026 NEC?
- 1.22130.60 – How must Power Control Systems (PCS) handle malfunctions under the 2026 NEC?1 Question
- 1.23130.70 – How Must Power Control System (PCS) Settings Be Configured?
- 1.24130.70 – How Must Power Control System (PCS) Settings Be Configured?1 Question
- 1.25240.67 – How has Arc Energy Reduction for Large Fuses been Updated?
- 1.26240.67 – How has Arc Energy Reduction for Large Fuses been Updated?1 Question
- 1.27240.87 – How Has Arc Energy Reduction Terminology Updated?
- 1.28240.87 – How Has Arc Energy Reduction Terminology Updated?1 Question
- 1.29242.1 – How Has the Scope of Article 242 Changed for DC Systems?
- 1.30242.1 – How Has the Scope of Article 242 Changed for DC Systems?1 Question
- 1.31242.54 – How have cross-references for surge arrester interconnections changed?
- 1.32242.54 – How have cross-references for surge arrester interconnections changed?1 Question
- 1.33268.31 – New Requirements for Service Conductor Sizing and Ampacity
- 1.34268.31 – New Requirements for Service Conductor Sizing and Ampacity1 Question
- 1.35268.42 – How are Medium Voltage Service Conductors Sized in the 2026 NEC?
- 1.36268.42 – How are Medium Voltage Service Conductors Sized in the 2026 NEC?1 Question
- 1.37270.122 – New Article 270: Sizing EGCs for Medium Voltage Systems
- 1.38270.122 – New Article 270: Sizing EGCs for Medium Voltage Systems1 Question
- 1.39270.166 – How are DC Grounding Electrode Conductors Sized in the 2026 NEC?
- 1.40270.166 – How are DC Grounding Electrode Conductors Sized in the 2026 NEC?1 Question
- 1.41270.66 – How Do You Size AC Grounding Electrode Conductors for Systems Over 1000V AC/1500V DC in 2026?
- 1.42270.66 – How Do You Size AC Grounding Electrode Conductors for Systems Over 1000V AC/1500V DC in 2026?1 Question
- 1.43406.46 – Have Switch Ratings Moved to Article 406?
- 1.44406.46 – Have Switch Ratings Moved to Article 406?1 Question
- 1.45422.11 – New Acronyms and Relocated Tables for Appliance Protection
- 1.46422.11 – New Acronyms and Relocated Tables for Appliance Protection1 Question
- 1.47525.24 – How has GFCI Protection for Carnivals and Fairs Changed?
- 1.48525.24 – How has GFCI Protection for Carnivals and Fairs Changed?1 Question
- 1.49555.35 – New Fire Pump Rules and GFPE Testing in Marinas
- 1.50555.35 – New Fire Pump Rules and GFPE Testing in Marinas1 Question
- 1.51625.42 – How has EVSE Load Management changed in the 2026 NEC?
- 1.52625.42 – How has EVSE Load Management changed in the 2026 NEC?1 Question
- 1.53680.10 – How has NEC 680.10 changed for Pool Heaters and Heat Pumps?
- 1.54680.10 – How has NEC 680.10 changed for Pool Heaters and Heat Pumps?1 Question
- 1.55680.75 – Does the 2026 NEC Change GFCI Rules for Hydromassage Tubs?
- 1.56680.75 – Does the 2026 NEC Change GFCI Rules for Hydromassage Tubs?1 Question
- 1.57700.32 – When is Re-Evaluation Required for Selective Coordination?
- 1.58700.32 – When is Re-Evaluation Required for Selective Coordination?1 Question
- 1.59700.5 – Where Did the Transfer Equipment Rules Go? (Restructuring 700.5)
- 1.60700.5 – Where Did the Transfer Equipment Rules Go? (Restructuring 700.5)1 Question
- 1.61701.5 – NEC 701.5: Capacity, Rating, and the Shift from Transfer Equipment
- 1.62701.5 – NEC 701.5: Capacity, Rating, and the Shift from Transfer Equipment1 Question
- NEC 2026: Grounding, Bonding, and Services64
- 2.1225.30 – Can Multiple Feeders Supply One Building? (2026 Update)
- 2.2225.30 – Can Multiple Feeders Supply One Building? (2026 Update)1 Question
- 2.3230.71 – How Many Service Disconnects? 2026 Updates to 230.71
- 2.4230.71 – How Many Service Disconnects? 2026 Updates to 230.711 Question
- 2.5230.95 – New GFPE Requirements for DC Services
- 2.6230.95 – New GFPE Requirements for DC Services1 Question
- 2.7250.109 – How Do You Bond Metal Raceways in Nonmetallic Boxes?
- 2.8250.109 – How Do You Bond Metal Raceways in Nonmetallic Boxes?1 Question
- 2.9250.119 – Are Yellow Wires with Green Stripes Allowed for Hot Circuits?
- 2.10250.119 – Are Yellow Wires with Green Stripes Allowed for Hot Circuits?1 Question
- 2.11250.146 – How Has the Structure for Receptacle Grounding Changed?
- 2.12250.146 – How Has the Structure for Receptacle Grounding Changed?1 Question
- 2.13250.30 – Grounding Separately Derived Systems: Terminology and References
- 2.14250.30 – Grounding Separately Derived Systems: Terminology and References1 Question
- 2.15250.4 – Performance Requirements: Clarifying Grounding and Bonding
- 2.16250.4 – Performance Requirements: Clarifying Grounding and Bonding1 Question
- 2.17250.64 – Can You Run a GEC Through a Mounting Hole? (2026 Update)
- 2.18250.64 – Can You Run a GEC Through a Mounting Hole? (2026 Update)1 Question
- 2.19250.68 – Refining Grounding Electrode Connections
- 2.20250.68 – Refining Grounding Electrode Connections1 Question
- 2.21250.94 – Ensuring Verified Safety: New Listing Requirements for Intersystem Bonding
- 2.22250.94 – Ensuring Verified Safety: New Listing Requirements for Intersystem Bonding1 Question
- 2.23268.1 – Where Did Medium Voltage Services Go in the 2026 NEC?
- 2.24268.1 – Where Did Medium Voltage Services Go in the 2026 NEC?1 Question
- 2.25268.40 – New Location, Same Critical Rules: Limiting Service-Entrance Conductor Sets
- 2.26268.40 – New Location, Same Critical Rules: Limiting Service-Entrance Conductor Sets1 Question
- 2.27268.70 – Where Must High-Voltage Service Disconnects Be Located in the 2026 NEC?
- 2.28268.70 – Where Must High-Voltage Service Disconnects Be Located in the 2026 NEC?1 Question
- 2.29270.102 – How are Bonding Jumpers Sized and Installed for Systems Over 1000V AC / 1500V DC in the 2026 NEC?
- 2.30270.102 – How are Bonding Jumpers Sized and Installed for Systems Over 1000V AC / 1500V DC in the 2026 NEC?1 Question
- 2.31270.104 – How is Bonding of Piping and Structural Metal Handled for Systems Over 1000V AC / 1500V DC in the 2026 NEC?
- 2.32270.104 – How is Bonding of Piping and Structural Metal Handled for Systems Over 1000V AC / 1500V DC in the 2026 NEC?1 Question
- 2.33270.115 – Relocation of Grounding Rules for Portable Equipment on Systems Over 1000V AC / 1500V DC
- 2.34270.115 – Relocation of Grounding Rules for Portable Equipment on Systems Over 1000V AC / 1500V DC1 Question
- 2.35270.118 – Where are Equipment Grounding Conductors Defined for Systems Over 1000V AC / 1500V DC in the 2026 NEC?
- 2.36270.118 – Where are Equipment Grounding Conductors Defined for Systems Over 1000V AC / 1500V DC in the 2026 NEC?1 Question
- 2.37270.119 – New Article 270: EGC Identification Rules for Systems Over 1000V AC / 1500V DC
- 2.38270.119 – New Article 270: EGC Identification Rules for Systems Over 1000V AC / 1500V DC1 Question
- 2.39270.120 – How are Equipment Grounding Conductors Installed for Systems Over 1000V AC / 1500V DC in 2026?
- 2.40270.120 – How are Equipment Grounding Conductors Installed for Systems Over 1000V AC / 1500V DC in 2026?1 Question
- 2.41270.14 – Where Did Substation Fence Grounding Go? (Relocation & Updates)
- 2.42270.14 – Where Did Substation Fence Grounding Go? (Relocation & Updates)1 Question
- 2.43270.27 – Relocation of Medium Voltage Grounding Rules and New Exceptions
- 2.44270.27 – Relocation of Medium Voltage Grounding Rules and New Exceptions1 Question
- 2.45270.28 – How are Main and System Bonding Jumpers Regulated for Systems Over 1000V AC / 1500V DC in the 2026 NEC?
- 2.46270.28 – How are Main and System Bonding Jumpers Regulated for Systems Over 1000V AC / 1500V DC in the 2026 NEC?1 Question
- 2.47270.30 – Where Did Transformer Bonding Go? Introduction to Section 270.30 for Systems Over 1000V AC / 1500V DC
- 2.48270.30 – Where Did Transformer Bonding Go? Introduction to Section 270.30 for Systems Over 1000V AC / 1500V DC1 Question
- 2.49270.32 – Grounding Requirements for Separate Buildings for Systems Over 1000V AC / 1500V DC (New Section 270.32)
- 2.50270.32 – Grounding Requirements for Separate Buildings for Systems Over 1000V AC / 1500V DC (New Section 270.32)1 Question
- 2.51270.34 – When Do Portable Generators Require a Ground Rod for Systems Over 1000V AC / 1500V DC?
- 2.52270.34 – When Do Portable Generators Require a Ground Rod for Systems Over 1000V AC / 1500V DC?1 Question
- 2.53270.36 – New Location and Rules for Impedance Grounded Systems Over 1000V AC / 1500V DC
- 2.54270.36 – New Location and Rules for Impedance Grounded Systems Over 1000V AC / 1500V DC1 Question
- 2.55270.4 – Where Did the General Grounding Requirements Go (for systems over 1000vac/1500vdc) in 2026?
- 2.56270.4 – Where Did the General Grounding Requirements Go (for systems over 1000vac/1500vdc) in 2026?1 Question
- 2.57270.6 – How Do I Handle Objectionable Current in the 2026 NEC for systems over 1000vac/1500vdc?
- 2.58270.6 – How Do I Handle Objectionable Current in the 2026 NEC for systems over 1000vac/1500vdc?1 Question
- 2.59270.64 – Where are Grounding Electrode Conductor Rules for systems over 1000vac/1500vdc in 2026 ?
- 2.60270.64 – Where are Grounding Electrode Conductor Rules for systems over 1000vac/1500vdc in 2026 ?1 Question
- 2.61270.68 – Where Did Grounding Connections Go for system over 1000vac/1500vdc? New Section 270.68
- 2.62270.68 – Where Did Grounding Connections Go for system over 1000vac/1500vdc? New Section 270.681 Question
- 2.63270.94 – Where Are Intersystem Bonding Requirements Located for Systems Over 1000V AC / 1500V DC in the 2026 NEC?
- 2.64270.94 – Where Are Intersystem Bonding Requirements Located for Systems Over 1000V AC / 1500V DC in the 2026 NEC?1 Question
- NEC 2026: Wiring Methods and Equipment62
- 3.1300.13 – Major Relocation: Securing and Supporting Moves to Section 300.13
- 3.2300.13 – Major Relocation: Securing and Supporting Moves to Section 300.131 Question
- 3.3300.24 – Is the 360-Degree Bend Limit Now a General Requirement?
- 3.4300.24 – Is the 360-Degree Bend Limit Now a General Requirement?1 Question
- 3.5300.5 – Major Restructuring: Section 300.5 is Now “Conductors”
- 3.6300.5 – Major Restructuring: Section 300.5 is Now “Conductors”1 Question
- 3.7305.14 – Where Did the Physical Damage Protection Rules Go? (Systems over 1000VAC/1500VDC)
- 3.8305.14 – Where Did the Physical Damage Protection Rules Go? (Systems over 1000VAC/1500VDC)1 Question
- 3.9305.21 – New General Requirements for Securing and Supporting Wiring Methods (Systems over 1000VAC/1500VDC)
- 3.10305.21 – New General Requirements for Securing and Supporting Wiring Methods (Systems over 1000VAC/1500VDC)1 Question
- 3.11305.29 – Where Did Vertical Raceway Supports Go? (New Section 305.29)
- 3.12305.29 – Where Did Vertical Raceway Supports Go? (New Section 305.29)1 Question
- 3.13305.32 – Wiring in Ducts and Plenums (Section 305.32) (Systems over 1000VAC/1500VDC)
- 3.14305.32 – Wiring in Ducts and Plenums (Section 305.32) (Systems over 1000VAC/1500VDC)1 Question
- 3.15312.11 – Where did the Rules for Splices in Switch Enclosures Go?
- 3.16312.11 – Where did the Rules for Splices in Switch Enclosures Go?1 Question
- 3.17314.27 – Outlet Box Support and Fan Box Locations: 2026 Revisions
- 3.18314.27 – Outlet Box Support and Fan Box Locations: 2026 Revisions1 Question
- 3.19402.13 – Where Did Table 402.3 Go? New Location for Fixture Wire Types
- 3.20402.13 – Where Did Table 402.3 Go? New Location for Fixture Wire Types1 Question
- 3.21404.2 – Where Did the “Neutral at the Switch” Rule Go? (New Listing Requirements)
- 3.22404.2 – Where Did the “Neutral at the Switch” Rule Go? (New Listing Requirements)1 Question
- 3.23406.16 – Did Receptacle Faceplate Rules Move?
- 3.24406.16 – Did Receptacle Faceplate Rules Move?1 Question
- 3.25406.18 – Where did the rules for Attachment Plugs and Connectors go in 2026?
- 3.26406.18 – Where did the rules for Attachment Plugs and Connectors go in 2026?1 Question
- 3.27406.19 – Where Did Grounding-Type Receptacle Rules Go? (Relocation to 406.19)
- 3.28406.19 – Where Did Grounding-Type Receptacle Rules Go? (Relocation to 406.19)1 Question
- 3.29406.26 – Where are Tamper-Resistant Receptacles Now Required?
- 3.30406.26 – Where are Tamper-Resistant Receptacles Now Required?1 Question
- 3.31406.28 – Where Did Single-Pole Separable Connectors Go? Understanding New Section 406.28
- 3.32406.28 – Where Did Single-Pole Separable Connectors Go? Understanding New Section 406.281 Question
- 3.33406.30 – Where Did the Neutral Rule Go? Relocation of Switch Connections
- 3.34406.30 – Where Did the Neutral Rule Go? Relocation of Switch Connections1 Question
- 3.35406.38 – Where Did the Switch Grouping Rule Go? Understanding New Section 406.38
- 3.36406.38 – Where Did the Switch Grouping Rule Go? Understanding New Section 406.381 Question
- 3.37406.40 – Switch Faceplates Relocated and Expanded to Include Dimmers and Control Switches
- 3.38406.40 – Switch Faceplates Relocated and Expanded to Include Dimmers and Control Switches1 Question
- 3.39406.9 – 406.9 includes switches now?
- 3.40406.9 – 406.9 includes switches now?1 Question
- 3.41409.110 – SCCR Visibility and Marking Updates for Industrial Control Panels
- 3.42409.110 – SCCR Visibility and Marking Updates for Industrial Control Panels1 Question
- 3.43410.116 – Recessed Luminaire Clearances and Fire-Rated Installations
- 3.44410.116 – Recessed Luminaire Clearances and Fire-Rated Installations1 Question
- 3.45410.64 – Can Luminaires Be Used as Raceways?
- 3.46410.64 – Can Luminaires Be Used as Raceways?1 Question
- 3.47426.60 – How Does the 2026 NEC Address Conductive Pavement Heating?
- 3.48426.60 – How Does the 2026 NEC Address Conductive Pavement Heating?1 Question
- 3.49426.62 – Where are Conductive Pavement Heating Systems Prohibited?
- 3.50426.62 – Where are Conductive Pavement Heating Systems Prohibited?1 Question
- 3.51625.2 – How Have Listing Requirements for EV Equipment Changed?
- 3.52625.2 – How Have Listing Requirements for EV Equipment Changed?1 Question
- 3.53625.40 – Did the Exception for EV Branch Circuits Change in 2026?
- 3.54625.40 – Did the Exception for EV Branch Circuits Change in 2026?1 Question
- 3.55625.43 – Emergency Shutoffs and Expanded Disconnect Rules for EVSE
- 3.56625.43 – Emergency Shutoffs and Expanded Disconnect Rules for EVSE1 Question
- 3.57625.44 – New Plug Ratings and Voltage Options for EV Chargers
- 3.58625.44 – New Plug Ratings and Voltage Options for EV Chargers1 Question
- 3.59625.5 – Are You Labeling EVSE Correctly Under the New 2026 Rules?
- 3.60625.5 – Are You Labeling EVSE Correctly Under the New 2026 Rules?1 Question
- 3.61706.31 – Did the 2026 NEC Remove the Current-Limiting Requirement for ESS?
- 3.62706.31 – Did the 2026 NEC Remove the Current-Limiting Requirement for ESS?1 Question
- NEC 2026: Special Conditions30
- 4.1500.30 – How Does the New Section 500.30 Standardize Bonding in Hazardous Locations?
- 4.2500.30 – How Does the New Section 500.30 Standardize Bonding in Hazardous Locations?1 Question
- 4.3500.7 – Does Gas Detection Replace Purge Cycles in Hazardous Locations?
- 4.4500.7 – Does Gas Detection Replace Purge Cycles in Hazardous Locations?1 Question
- 4.5500.8 – Clarifying Equipment vs. Installation in Hazardous Locations
- 4.6500.8 – Clarifying Equipment vs. Installation in Hazardous Locations1 Question
- 4.7501.10 – How 501.10 Transformed Wiring Methods into Tables
- 4.8501.10 – How 501.10 Transformed Wiring Methods into Tables1 Question
- 4.9501.15 – Clarifying Boundary Seals and Cable Types in Hazardous Locations
- 4.10501.15 – Clarifying Boundary Seals and Cable Types in Hazardous Locations1 Question
- 4.11511.6 – How Have Commercial Garage Rules Changed for 2026?
- 4.12511.6 – How Have Commercial Garage Rules Changed for 2026?1 Question
- 4.13516.8 – Spray Area Safety: Renumbering and Static Grounding Requirements
- 4.14516.8 – Spray Area Safety: Renumbering and Static Grounding Requirements1 Question
- 4.15516.9 – New Location for Wiring Rules Above Spray Areas
- 4.16516.9 – New Location for Wiring Rules Above Spray Areas1 Question
- 4.17590.4 – Where Did the Rules Go? Section 590.4 Completely Restructured
- 4.18590.4 – Where Did the Rules Go? Section 590.4 Completely Restructured1 Question
- 4.19625.17 – EVSE Cords: “Hand Fastened” Terminology and Ampacity Clarity
- 4.20625.17 – EVSE Cords: “Hand Fastened” Terminology and Ampacity Clarity1 Question
- 4.21680.2 – Is Listing Now Mandatory for All Pool and Spa Equipment?
- 4.22680.2 – Is Listing Now Mandatory for All Pool and Spa Equipment?1 Question
- 4.23680.23 – Clarified Bonding Requirements for Wet-Niche Luminaires
- 4.24680.23 – Clarified Bonding Requirements for Wet-Niche Luminaires1 Question
- 4.25680.26 – New Materials and Listing Extensions for Pool Bonding
- 4.26680.26 – New Materials and Listing Extensions for Pool Bonding1 Question
- 4.27680.42 – How have the references in Section 680.42 changed for 2026?
- 4.28680.42 – How have the references in Section 680.42 changed for 2026?1 Question
- 4.29680.5 – How Have GFCI Requirements for 3-Phase Pool Equipment Changed?
- 4.30680.5 – How Have GFCI Requirements for 3-Phase Pool Equipment Changed?1 Question
- North Dakota Laws, Rules and Wiring Standards (2026)40
- 5.1See how North Dakota’s electrical rules fit together3 Minutes
- 5.2Quiz: How the rules fit together1 Question
- 5.3Decide which requirement governs when codes differ3 Minutes
- 5.4Quiz: Which rule governs1 Question
- 5.5Get special permission and approval for unlisted equipment3 Minutes
- 5.6Quiz: Special permission1 Question
- 5.7Recognize the work that requires a board license3 Minutes
- 5.8Quiz: When a license is required1 Question
- 5.9Compare the four electrician license classes3 Minutes
- 5.10Quiz: License classes1 Question
- 5.11Tell power limited systems from nonelectrical systems3 Minutes
- 5.12Quiz: Power limited or nonelectrical1 Question
- 5.13Identify the exemptions from licensing3 Minutes
- 5.14Quiz: Exemptions1 Question
- 5.15Know what maintenance staff and self-wiring owners may do3 Minutes
- 5.16Quiz: Maintenance and self-wiring1 Question
- 5.17Supervise apprentices lawfully3 Minutes
- 5.18Quiz: Apprentice supervision1 Question
- 5.19Recognize the grounds for losing a license3 Minutes
- 5.20Quiz: Grounds for discipline1 Question
- 5.21Know when a wiring certificate is required3 Minutes
- 5.22Quiz: Certificate required1 Question
- 5.23File and distribute the wiring certificate3 Minutes
- 5.24Quiz: Filing the certificate1 Question
- 5.25Manage certificate validity, e-certs and lost certificates3 Minutes
- 5.26Quiz: Validity and e-certs1 Question
- 5.27Meet the general requirements for every installation3 Minutes
- 5.28Quiz: General requirements1 Question
- 5.29Wire remodels, changes of occupancy, schools and hospitals3 Minutes
- 5.30Quiz: Remodels1 Question
- 5.31Deal with water-damaged electrical equipment3 Minutes
- 5.32Quiz: Water damage1 Question
- 5.33Lay out dwelling and public kitchen branch circuits3 Minutes
- 5.34Quiz: Kitchen circuits1 Question
- 5.35Apply the GFCI, AFCI and receptacle exceptions3 Minutes
- 5.36Quiz: GFCI and AFCI exceptions1 Question
- 5.37Install smoke, heat and carbon monoxide alarms3 Minutes
- 5.38Quiz: Alarms1 Question
- 5.39Provide egress marking, illumination and emergency lighting3 Minutes
- 5.40Quiz: Egress lighting1 Question