Covers 2026 National Electrical Code changes for special systems, beginning with solar photovoltaic systems in Article 690, including rapid shutdown, PV disconnects, listing, system voltage calculation and labeling, and circuit sizing for bifacial modules. Participants then review interconnected power sources in Article 705, including source connections to a service, source disconnecting means, and ground-fault protection, along with flexible cords for wind turbines.
The course then addresses limited-energy systems in Articles 720 through 723, including underground installation, physical protection, cable support, power sources, cable listing and marking, mixing of cables, and raceways, along with communications, coaxial, network-powered broadband, optical fiber, and fire alarm cables. Later lessons cover primary protection for communication systems in new Article 742, communications and antenna grounding in Article 750, including mobile homes and premises-powered broadband, and communication entry requirements.
Learning objectives
- Identify changes to PV system requirements in Article 690, including rapid shutdown, disconnects, and system voltage calculation and labeling.
- Apply Article 705 requirements for connecting interconnected power sources to a service.
- Select limited-energy and communications cables and raceways using the 2026 installation tables and listing requirements.
- Locate grounding and primary protection requirements for communication and antenna systems in Articles 742 and 750.
Disclosure of proprietary interest. No instructor, subject-matter expert or content author involved in developing or delivering this course holds any financial or ownership interest in any product, instrument, device or material referenced in it, and none receives any royalty, profit share or other consideration from the promotion or endorsement of any product. This course does not endorse any commercial product or service.
Course Features
- Lectures 47
- Quizzes 44
- Duration 52 weeks
- Skill level All levels
- Language English
- Students 16
- Certificate Yes
- Assessments Self
- Format Audio + Text
- 1 Section
- 47 Lessons
- Lessons91
- 1.1Course Orientation
- 1.2About the Course Timer
- 1.3Learning Objectives
- 1.4690.12 – Updates to Rapid Shutdown Initiation and Control
- 1.5690.12 – Updates to Rapid Shutdown Initiation and Control1 Question
- 1.6690.13 – Where Did the PV Disconnect Rules Go?
- 1.7690.13 – Where Did the PV Disconnect Rules Go?1 Question
- 1.8690.15 – How Have PV Equipment Disconnect Requirements Changed?
- 1.9690.15 – How Have PV Equipment Disconnect Requirements Changed?1 Question
- 1.10690.2 – Where Did the PV Listing Requirements Go in the 2026 NEC?
- 1.11690.2 – Where Did the PV Listing Requirements Go in the 2026 NEC?1 Question
- 1.12690.4 – How Have General PV Requirements and Calculation Rules Changed?
- 1.13690.4 – How Have General PV Requirements and Calculation Rules Changed?1 Question
- 1.14690.7 – How Has Calculating and Labeling PV System Voltage Changed?
- 1.15690.7 – How Has Calculating and Labeling PV System Voltage Changed?1 Question
- 1.16690.8 – How do I size circuits for Bifacial Modules and EPCs in 2026?
- 1.17690.8 – How do I size circuits for Bifacial Modules and EPCs in 2026?1 Question
- 1.18694.30 – How have Flexible Cord Requirements for Wind Turbines Changed?
- 1.19694.30 – How have Flexible Cord Requirements for Wind Turbines Changed?1 Question
- 1.20705.11 – How have Source Connections to a Service changed in 2026?
- 1.21705.11 – How have Source Connections to a Service changed in 2026?1 Question
- 1.22705.20 – How has the NEC Restructured Source Disconnecting Means?
- 1.23705.20 – How has the NEC Restructured Source Disconnecting Means?1 Question
- 1.24705.32 – How Has Ground-Fault Protection Changed for Interconnected Power Sources?
- 1.25705.32 – How Has Ground-Fault Protection Changed for Interconnected Power Sources?1 Question
- 1.26720.19 – How must limited-energy cables in vertical raceways be supported in the 2026 NEC?
- 1.27720.19 – How must limited-energy cables in vertical raceways be supported in the 2026 NEC?1 Question
- 1.28720.22 – New Plenum Requirements for Low-Voltage Systems (Section 720.22)
- 1.29720.22 – New Plenum Requirements for Low-Voltage Systems (Section 720.22)1 Question
- 1.30720.30 – Where Did the Rules for Supporting Limited-Energy Cables Go in 2026?
- 1.31720.30 – Where Did the Rules for Supporting Limited-Energy Cables Go in 2026?1 Question
- 1.32720.5 – How are Underground Installations for Limited-Energy Systems Regulated in 2026?
- 1.33720.5 – How are Underground Installations for Limited-Energy Systems Regulated in 2026?1 Question
- 1.34720.6 – New Physical Protection Standards for Limited Energy Systems
- 1.35720.6 – New Physical Protection Standards for Limited Energy Systems1 Question
- 1.36720.7 – How Does the 2026 NEC Address Corrosion in Limited-Energy Systems?
- 1.37720.7 – How Does the 2026 NEC Address Corrosion in Limited-Energy Systems?1 Question
- 1.38720.8 – How Must Low-Voltage Raceways Handle Temperature Changes?
- 1.39720.8 – How Must Low-Voltage Raceways Handle Temperature Changes?1 Question
- 1.40721.1 – Where Have the Power Source Rules Gone?
- 1.41721.1 – Where Have the Power Source Rules Gone?1 Question
- 1.42722.100 – New Marking Standards for Limited-Energy Cables
- 1.43722.100 – New Marking Standards for Limited-Energy Cables1 Question
- 1.44722.120 – How do I determine where Limited Energy Cables can be installed in 2026?
- 1.45722.120 – How do I determine where Limited Energy Cables can be installed in 2026?1 Question
- 1.46722.13 – New Consolidation: Mixing Limited-Energy Cables in 2026
- 1.47722.13 – New Consolidation: Mixing Limited-Energy Cables in 20261 Question
- 1.48722.130 – New Master Table for Communications Cable Applications
- 1.49722.130 – New Master Table for Communications Cable Applications1 Question
- 1.50722.131 – Where Have the Communications Cable Installation Rules Moved?
- 1.51722.131 – Where Have the Communications Cable Installation Rules Moved?1 Question
- 1.52722.133 – New Home for Communication and Coaxial Cable Installation Rules
- 1.53722.133 – New Home for Communication and Coaxial Cable Installation Rules1 Question
- 1.54722.134 – How are Low- and Medium-Power Network-Powered Broadband Cables Installed in 2026?
- 1.55722.134 – How are Low- and Medium-Power Network-Powered Broadband Cables Installed in 2026?1 Question
- 1.56722.136 – How Do You Handle Cable Substitutions for Low-Power Broadband Systems in 2026?
- 1.57722.136 – How Do You Handle Cable Substitutions for Low-Power Broadband Systems in 2026?1 Question
- 1.58722.160 – Where Did Optical Fiber Applications Go in the 2026 NEC?
- 1.59722.160 – Where Did Optical Fiber Applications Go in the 2026 NEC?1 Question
- 1.60722.161 – New Location for Optical Fiber Installation Rules
- 1.61722.161 – New Location for Optical Fiber Installation Rules1 Question
- 1.62722.164 – Can Optical Fiber and Power Conductors Share the Same Raceway?
- 1.63722.164 – Can Optical Fiber and Power Conductors Share the Same Raceway?1 Question
- 1.64722.170 – Where Can You Install Fire Alarm Cables? New Section 722.170
- 1.65722.170 – Where Can You Install Fire Alarm Cables? New Section 722.1701 Question
- 1.66722.2 – How are Listing Requirements for Limited-Energy Cables Changing?
- 1.67722.2 – How are Listing Requirements for Limited-Energy Cables Changing?1 Question
- 1.68723.20 – Where Can You Install Limited-Energy Raceways?
- 1.69723.20 – Where Can You Install Limited-Energy Raceways?1 Question
- 1.70723.22 – How are Raceways for Limited-Energy Systems Regulated in 2026?
- 1.71723.22 – How are Raceways for Limited-Energy Systems Regulated in 2026?1 Question
- 1.72723.30 – Where Can You Install Cable Routing Assemblies?
- 1.73723.30 – Where Can You Install Cable Routing Assemblies?1 Question
- 1.74742.10 – New Article 742: Primary Protection for Communication Systems
- 1.75742.10 – New Article 742: Primary Protection for Communication Systems1 Question
- 1.76750.100 – Where Did Communications Grounding Go? New Section 750.100
- 1.77750.100 – Where Did Communications Grounding Go? New Section 750.1001 Question
- 1.78750.106 – How Has Communication Grounding at Mobile Homes Changed in 2026?
- 1.79750.106 – How Has Communication Grounding at Mobile Homes Changed in 2026?1 Question
- 1.80750.110 – Where Must Metal Entrance Conduit for Optical Fiber Be Grounded?
- 1.81750.110 – Where Must Metal Entrance Conduit for Optical Fiber Be Grounded?1 Question
- 1.82750.48 – New Location for Communications Grounding Requirements
- 1.83750.48 – New Location for Communications Grounding Requirements1 Question
- 1.84750.60 – How are Antenna Systems Grounded in Article 750?
- 1.85750.60 – How are Antenna Systems Grounded in Article 750?1 Question
- 1.86750.80 – How are Premises-Powered Broadband Systems Grounded in 2026?
- 1.87750.80 – How are Premises-Powered Broadband Systems Grounded in 2026?1 Question
- 1.88760.2 – Where are the Listing Requirements for NPLFA Cables in the 2026 NEC?
- 1.89760.2 – Where are the Listing Requirements for NPLFA Cables in the 2026 NEC?1 Question
- 1.90800.50 – Where Did the Communication Entry Requirements Go?
- 1.91800.50 – Where Did the Communication Entry Requirements Go?1 Question