Provides an analysis of foundational and specialty requirements, beginning with conductor ampacity and advancing through complex system ratings. Participants will examine specific code changes regarding branch circuit loads, lighting requirements, and the calculation of receptacle loads for diverse environments, including marinas and docking facilities.
The course further explores critical safety requirements for modern infrastructure, covering Electric Vehicle Supply Equipment (EVSE), Energy Management Systems (EMS), and the selective coordination of overcurrent devices. Specialized modules cover complex installations such as island and peninsular countertops, motor rating determinations, and emergency system capacities. By analyzing specific tables and articles like 240.6 and 705.12, attendees will gain needed insights to ensure voltage drop compliance and proper feeder tap installations in residential, commercial, and industrial settings.
Learning objectives
- Calculate minimum ampacity and size for conductors and determine permissible loads for multiple-outlet branch circuits.
- Identify required lighting outlets and calculate floor area requirements according to updated standards.
- Apply sizing and rating standards for overcurrent protection, including remotely accessible adjustable-trip circuit breakers.
- Evaluate installation dimensions for boxes and the length of free conductors at junctions and switch points.
- Determine the capacity and supply duration requirements for emergency systems and fire pumps.
- Implement correct ratings for specialized equipment, including ceiling-suspended fans, HVAC equipment, and solar PV feeder taps.
Course Features
- Lectures 32
- Quizzes 31
- Duration 52 weeks
- Skill level All levels
- Language English
- Students 1
- Certificate Yes
- Assessments Self
- 5 Sections
- 32 Lessons
- NEC 2023 - Theory and Calculations - NEC Courses Article 200 Series33
- 1.1Course Orientation
- 1.2210.19 Conductors – Minimum Ampacity and Size
- 1.3210.19 Conductors – Minimum Ampacity and Size1 Question
- 1.4210.23 Permissible Loads, Multiple-Outlet Branch Circuits
- 1.5210.23 Permissible Loads, Multiple-Outlet Branch Circuits1 Question
- 1.6210.70 Lighting Outlets Required
- 1.7210.70 Lighting Outlets Required1 Question
- 1.8220.110 Receptacle Loads
- 1.9220.110 Receptacle Loads1 Question
- 1.10220.120 Marinas, Boatyards, Floating Buildings, And Commercial and Noncommercial Docking Facilities
- 1.11220.120 Marinas, Boatyards, Floating Buildings, And Commercial and Noncommercial Docking Facilities1 Question
- 1.12220.57 Electric Vehicle Supply Equipment
- 1.13220.57 Electric Vehicle Supply Equipment1 Question
- 1.14220.70 Energy Management Systems (EMSs)
- 1.15220.70 Energy Management Systems (EMSs)1 Question
- 1.16215.15 Barriers
- 1.17215.15 Barriers1 Question
- 1.18210.52(C) Island and Peninsular Countertops and Work Surfaces
- 1.19210.52(C) Island and Peninsular Countertops and Work Surfaces1 Question
- 1.20220.5(C) Floor Areas
- 1.21220.5(C) Floor Areas1 Question
- 1.22230.71(B) Two to Six Disconnecting Means
- 1.23230.71(B) Two to Six Disconnecting Means1 Question
- 1.24240.11 Selective Coordination
- 1.25240.11 Selective Coordination1 Question
- 1.26240.4(B) Overcurrent Devices Rated 8000 Amperes or Less
- 1.27240.4(B) Overcurrent Devices Rated 8000 Amperes or Less1 Question
- 1.28240.4(D)(3) 14 AWG Copper-Clad Aluminum
- 1.29240.4(D)(3) 14 AWG Copper-Clad Aluminum1 Question
- 1.30Table 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers
- 1.31Table 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers1 Question
- 1.32Table 240.6(D) Remotely Accessible Adjustable-Trip Circuit Breakers
- 1.33Table 240.6(D) Remotely Accessible Adjustable-Trip Circuit Breakers1 Question
- NEC 2023 - Theory and Calculations - NEC Courses Article 300 Series6
- NEC 2023 - Theory and Calculations - NEC Courses Article 400 Series10
- 3.1404.14 Rating and Use of Switches
- 3.2404.14 Rating and Use of Switches1 Question
- 3.3406.3 Receptacle Rating and Type
- 3.4406.3 Receptacle Rating and Type1 Question
- 3.5422.18 Ceiling-Suspended (Paddle) Fans
- 3.6422.18 Ceiling-Suspended (Paddle) Fans1 Question
- 3.7430.6 Conductor Ampacity and Motor Rating Determination
- 3.8430.6 Conductor Ampacity and Motor Rating Determination1 Question
- 3.9440.8 Single Machine and Location
- 3.10440.8 Single Machine and Location1 Question
- NEC 2023 - Theory and Calculations - NEC Courses Article 600 Series4
- NEC 2023 - Theory and Calculations - NEC Courses Article 700 Series10
- 5.1700.4 Capacity and Rating
- 5.2700.4 Capacity and Rating1 Question
- 5.3705.12(A) Feeders and Feeder Taps
- 5.4705.12(A) Feeders and Feeder Taps1 Question
- 5.5726.144 Ampacity
- 5.6726.144 Ampacity1 Question
- 5.7700.12(C) Supply Duration
- 5.8700.12(C) Supply Duration1 Question
- 5.9750.30(C) Capacity of Branch Circuit, Feeder, or Service
- 5.10750.30(C) Capacity of Branch Circuit, Feeder, or Service1 Question