Covers 2023 NEC changes across Chapters 1 through 8, beginning with general requirements in Article 110 and moving through branch circuits, feeders and services in Articles 210, 215, 225 and 230, wiring methods in Chapter 3, and equipment in Chapter 4. Participants then examine grounding and bonding requirements in Article 250, including grounding electrode conductors, equipment bonding jumpers and connections in boxes.
The course then addresses load calculations under Article 220 for dwellings and other occupancies, along with conductor sizing, overcurrent protection in Article 240 and motor circuits in Article 430. Later modules cover hazardous locations, health care facilities, swimming pools and fountains under Article 680, solar photovoltaic systems under Article 690, emergency systems under Article 700, and communications systems in Chapter 8.
Learning objectives
- Identify 2023 NEC changes in Articles 110, 210, 230, 240 and 300.
- Apply grounding and bonding requirements of Article 250 to services, electrodes and equipment.
- Calculate branch circuit, feeder and service loads using Article 220.
- Locate requirements in articles covering hazardous locations, pools and fountains, photovoltaic systems and emergency systems.
Disclosure of proprietary interest. No instructor, subject-matter expert or content author involved in developing or delivering this course holds any financial or ownership interest in any product, instrument, device or material referenced in it, and none receives any royalty, profit share or other consideration from the promotion or endorsement of any product. This course does not endorse any commercial product or service.
Course Features
- Lectures 144
- Quizzes 142
- Duration 52 weeks
- Skill level All levels
- Students 0
- Certificate Yes
- Assessments Self
- Format Audio + Text
- 20 Sections
- 144 Lessons
- NEC 2023 - Code Update (CH 1-8) - NEC Courses Article 100 Series16
- 1.1Course Orientation
- 1.2Learning Objectives
- 1.3110.20 – Reconditioned Equipment
- 1.4110.20 – Reconditioned Equipment1 Question
- 1.5110.21 – Markings
- 1.6110.21 – Markings1 Question
- 1.7110.16(B) – Arc-Flash Hazard Warnings – Service Equipment
- 1.8110.16(B) – Arc-Flash Hazard Warnings – Service Equipment1 Question
- 1.9110.2(B) When Required
- 1.10110.2(B) When Required1 Question
- 1.11110.22(A) – Identification of Disconnecting Means
- 1.12110.22(A) – Identification of Disconnecting Means1 Question
- 1.13120.6 Process for Establishing and Verifying an Electrically Safe Work Condition
- 1.14120.6 Process for Establishing and Verifying an Electrically Safe Work Condition1 Question
- 1.15130.7(C)(5) Hearing Protection
- 1.16130.7(C)(5) Hearing Protection1 Question
- NEC 2023 - Code Update (CH 1-8) - NEC Courses Article 200 Series20
- 2.1210.17 Guest Rooms and Guest Suites
- 2.2210.17 Guest Rooms and Guest Suites1 Question
- 2.3215.18 Surge Protection
- 2.4215.18 Surge Protection1 Question
- 2.5225.41 Emergency Disconnects
- 2.6225.41 Emergency Disconnects1 Question
- 2.7230.67 Surge Protection
- 2.8230.67 Surge Protection1 Question
- 2.9Article 235 – Branch Circuits, Feeders and Services over 1000 Volts AC, 1500 Volts DC, Nominal
- 2.10Article 235 – Branch Circuits, Feeders and Services over 1000 Volts AC, 1500 Volts DC, Nominal1 Question
- 2.11240.2 Reconditioned Equipment
- 2.12240.2 Reconditioned Equipment1 Question
- 2.13Article 245 – Overcurrent Protection over 1000 Volts AC, 1500 Volts DC
- 2.14Article 245 – Overcurrent Protection over 1000 Volts AC, 1500 Volts DC1 Question
- 2.15210.11(C)(4) Garage Branch Circuits
- 2.16210.11(C)(4) Garage Branch Circuits1 Question
- 2.17210.52(G) Basements, Garages, and Accessory Buildings
- 2.18210.52(G) Basements, Garages, and Accessory Buildings1 Question
- 2.19240.24(A) and (E) – Location in or on Premises
- 2.20240.24(A) and (E) – Location in or on Premises1 Question
- NEC 2023 - Code Update (CH 1-8) - NEC Courses Article 300 Series22
- 3.1315.17 Marking for Type Medium Voltage Cable Joints, and Terminations
- 3.2315.17 Marking for Type Medium Voltage Cable Joints, and Terminations1 Question
- 3.3315.32 Uses Permitted for Type Medium Voltage Cables, Cable Joints, and Terminations
- 3.4315.32 Uses Permitted for Type Medium Voltage Cables, Cable Joints, and Terminations1 Question
- 3.5369.10 Uses Permitted for Insulated Bus Pipe (IBP) Systems
- 3.6369.10 Uses Permitted for Insulated Bus Pipe (IBP) Systems1 Question
- 3.7369.120 Marking Insulated Bus Pipe (IBP) Systems
- 3.8369.120 Marking Insulated Bus Pipe (IBP) Systems1 Question
- 3.9371.17 Overcurrent Protection of Flexible Bus System
- 3.10371.17 Overcurrent Protection of Flexible Bus System1 Question
- 3.11371.30 Securing and Supporting
- 3.12371.30 Securing and Supporting1 Question
- 3.13398.15 Exposed Work
- 3.14398.15 Exposed Work1 Question
- 3.15300.3 (C) Conductors of Different Systems
- 3.16300.3 (C) Conductors of Different Systems1 Question
- 3.17300.11(C) Raceways Used as Means of Support
- 3.18300.11(C) Raceways Used as Means of Support1 Question
- 3.19320.3(A)(1) Electrical Hazard Thresholds.
- 3.20320.3(A)(1) Electrical Hazard Thresholds.10 Minutes1 Question
- 3.21371.10 and 371.12 Uses Permitted and Not Permitted
- 3.22371.10 and 371.12 Uses Permitted and Not Permitted1 Question
- NEC 2023 - Code Update (CH 1-8) - NEC Courses Article 400 Series22
- 4.1404.16 Reconditioned Equipment
- 4.2404.16 Reconditioned Equipment1 Question
- 4.3406.12 Tamper-Resistant Receptacles.
- 4.4406.12 Tamper-Resistant Receptacles.1 Question
- 4.5408.4 Descriptions Required
- 4.6408.4 Descriptions Required1 Question
- 4.7408.9 Replacement Panelboards
- 4.8408.9 Replacement Panelboards1 Question
- 4.9409.70 Surge Protection
- 4.10409.70 Surge Protection1 Question
- 4.11410.197 Germicidal Irradiation Systems
- 4.12410.197 Germicidal Irradiation Systems1 Question
- 4.13410.71(1) General
- 4.14410.71(1) General1 Question
- 4.15430.2 Reconditioned Motors
- 4.16430.2 Reconditioned Motors1 Question
- 4.17445.19 Emergency Shutdown of Prime Mover
- 4.18445.19 Emergency Shutdown of Prime Mover1 Question
- 4.19470.2 Reconditioned Equipment
- 4.20470.2 Reconditioned Equipment1 Question
- 4.21406.6(D) Receptacle Faceplate (Cover Plates) With Integral Night Light and/or USB Charger
- 4.22406.6(D) Receptacle Faceplate (Cover Plates) With Integral Night Light and/or USB Charger1 Question
- NEC 2023 - Code Update (CH 1-8) - NEC Courses Article 500 Series14
- 5.1512.13 Wiring Installed Above Hazardous (Classified) Locations
- 5.2512.13 Wiring Installed Above Hazardous (Classified) Locations1 Question
- 5.3517.30(B) Power Sources for the EES
- 5.4517.30(B) Power Sources for the EES1 Question
- 5.5518.5 Supply
- 5.6518.5 Supply1 Question
- 5.7547.26 Physical Protection
- 5.8547.26 Physical Protection1 Question
- 5.9500.5 (D) Classifications of Locations
- 5.10500.5 (D) Classifications of Locations1 Question
- 5.11512.3(A) Cannabis Oil Equipment and Systems Other Than Booths
- 5.12512.3(A) Cannabis Oil Equipment and Systems Other Than Booths1 Question
- 5.13512.3(B) Cannabis Oil Booths
- 5.14512.3(B) Cannabis Oil Booths1 Question
- NEC 2023 - Code Update (CH 1-8) - NEC Courses Article 600 Series26
- 6.1600.35 – Retrofit Kits
- 6.2600.35 – Retrofit Kits1 Question
- 6.3625.40 Electric Vehicle Branch Circuit
- 6.4625.40 Electric Vehicle Branch Circuit1 Question
- 6.5625.49 – Island Mode
- 6.6625.49 – Island Mode1 Question
- 6.7625.6 – Listed
- 6.8625.6 – Listed1 Question
- 6.9630.8 – Electric Welders
- 6.10630.8 – Electric Welders1 Question
- 6.11690.1 New illustration to help understand PV components
- 6.12690.1 New illustration to help understand PV components1 Question
- 6.13690.12 – Rapid Shutdown Requirements
- 6.14690.12 – Rapid Shutdown Requirements1 Question
- 6.15690.15 – Disconnecting Means for Isolating Photovoltaic Equipment
- 6.16690.15 – Disconnecting Means for Isolating Photovoltaic Equipment1 Question
- 6.17690.56 – Identification of Power Sources
- 6.18690.56 – Identification of Power Sources1 Question
- 6.19691.4 Special Requirements for Large-Scale PV Electric Supply Stations
- 6.20691.4 Special Requirements for Large-Scale PV Electric Supply Stations1 Question
- 6.21600.5(A) – Branch Circuits
- 6.22600.5(A) – Branch Circuits1 Question
- 6.23620.12(A) – Traveling Cables
- 6.24620.12(A) – Traveling Cables1 Question
- 6.25690.4(G) – PV Equipment Floating on Bodies of Water
- 6.26690.4(G) – PV Equipment Floating on Bodies of Water1 Question
- NEC 2023 - Code Update (CH 1-8) - NEC Courses Article 700 Series28
- 7.1700.11 Wiring, Class-2-Powered Emergency Lighting Systems
- 7.2700.11 Wiring, Class-2-Powered Emergency Lighting Systems1 Question
- 7.3700.12(E) Stored-Energy Power Supply Systems (SEPSS)
- 7.4700.12(E) Stored-Energy Power Supply Systems (SEPSS)1 Question
- 7.5700.27 Class 2 Powered Emergency Lighting Systems
- 7.6700.27 Class 2 Powered Emergency Lighting Systems1 Question
- 7.7700.32 Selective Coordination
- 7.8700.32 Selective Coordination1 Question
- 7.9700.3(F) Temporary Source of Power for Maintenance or Repair of the Alternate Source of Power
- 7.10700.3(F) Temporary Source of Power for Maintenance or Repair of the Alternate Source of Power1 Question
- 7.11701.10 Wiring Legally Required Standby Systems
- 7.12701.10 Wiring Legally Required Standby Systems1 Question
- 7.13701.4(C) Load Management
- 7.14701.4(C) Load Management1 Question
- 7.15705.10 Identification of Power Sources
- 7.16705.10 Identification of Power Sources1 Question
- 7.17706.7 Commissioning and Maintenance
- 7.18706.7 Commissioning and Maintenance1 Question
- 7.19726.121 Power Sources for Class 4 Circuits
- 7.20726.121 Power Sources for Class 4 Circuits1 Question
- 7.21726.122 Class 4 Loads
- 7.22726.122 Class 4 Loads1 Question
- 7.23726.124 Class 4 Marking
- 7.24726.124 Class 4 Marking1 Question
- 7.25726.130 Terminals and Connectors
- 7.26726.130 Terminals and Connectors1 Question
- 7.27700.12(G) Microgrid Systems
- 7.28700.12(G) Microgrid Systems1 Question
- NEC 2023 - Code Update (CH 1-8) - NEC Courses Article 800 Series4
- NEC 2023 - Grounding and Bonding - NEC Courses Article 100 Series4
- NEC 2023 - Grounding and Bonding - NEC Courses Article 200 Series22
- 10.1250.130 – Equipment Grounding Conductor Connections
- 10.2250.130 – Equipment Grounding Conductor Connections1 Question
- 10.3250.140 – Frames of Ranges and Clothes Dryers
- 10.4250.140 – Frames of Ranges and Clothes Dryers1 Question
- 10.5250.148 – Continuity of Equipment Grounding Conductors and Attachment in Boxes
- 10.6250.148 – Continuity of Equipment Grounding Conductors and Attachment in Boxes1 Question
- 10.7250.36 – Impedance Grounded Systems
- 10.8250.36 – Impedance Grounded Systems1 Question
- 10.9250.70 – Grounding and Bonding Conductor Connection to Electrodes
- 10.10250.70 – Grounding and Bonding Conductor Connection to Electrodes1 Question
- 10.11210.8(B) Other Than Dwelling Units
- 10.12210.8(B) Other Than Dwelling Units1 Question
- 10.13210.8(F) Outdoor Outlets.
- 10.14210.8(F) Outdoor Outlets.1 Question
- 10.15242.2 and 242.9 – Surge Protective Devices
- 10.16242.2 and 242.9 – Surge Protective Devices1 Question
- 10.17250.24(D) – Grounded Conductor Brought to Service Equipment
- 10.18250.24(D) – Grounded Conductor Brought to Service Equipment1 Question
- 10.19230.85 Emergency Disconnects
- 10.20230.85 Emergency Disconnects1 Question
- 10.21250.64(G) – Enclosures with Ventilation Openings
- 10.22250.64(G) – Enclosures with Ventilation Openings1 Question
- NEC 2023 - Grounding and Bonding - NEC Courses Article 400 Series6
- 11.1410.184 Ground-Fault Circuit-Interrupter (GFCI) Protection and Special Purpose Ground-Fault Circuit-Interrupter (SPGFCI) Protection
- 11.2410.184 Ground-Fault Circuit-Interrupter (GFCI) Protection and Special Purpose Ground-Fault Circuit-Interrupter (SPGFCI) Protection1 Question
- 11.3406.4(D) Receptacle Replacements
- 11.4406.4(D) Receptacle Replacements1 Question
- 11.5406.9 (C) Bathtub and Shower Space
- 11.6406.9 (C) Bathtub and Shower Space1 Question
- NEC 2023 - Grounding and Bonding - NEC Courses Article 500 Series18
- 12.1501.30 Grounding and Bonding
- 12.2501.30 Grounding and Bonding1 Question
- 12.3502.30 Grounding and Bonding
- 12.4502.30 Grounding and Bonding1 Question
- 12.5511.7(A) Wiring in Spaces Above Hazardous (Classified) Locations
- 12.6511.7(A) Wiring in Spaces Above Hazardous (Classified) Locations1 Question
- 12.7517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care Spaces
- 12.8517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care Spaces1 Question
- 12.9517.14 Panelboard Bonding
- 12.10517.14 Panelboard Bonding1 Question
- 12.11547.44 Equipotential Planes and Bonding of Equipotential Planes
- 12.12547.44 Equipotential Planes and Bonding of Equipotential Planes1 Question
- 12.13551.3 Electrical Datum Plane Distances
- 12.14551.3 Electrical Datum Plane Distances1 Question
- 12.15551.40 120-Volt or 120/240-Volt, Nominal, Systems
- 12.16551.40 120-Volt or 120/240-Volt, Nominal, Systems1 Question
- 12.17555.14 Equipotential Planes and Bonding of Equipotential Planes
- 12.18555.14 Equipotential Planes and Bonding of Equipotential Planes1 Question
- NEC 2023 - Grounding and Bonding - NEC Courses Article 600 Series18
- 13.1620.6 – GFCI Protection for Personnel
- 13.2620.6 – GFCI Protection for Personnel1 Question
- 13.3680.32 – GFCI and SPGFCI Protection
- 13.4680.32 – GFCI and SPGFCI Protection1 Question
- 13.5680.44 – GFCI & SPGFCI Protection
- 13.6680.44 – GFCI & SPGFCI Protection1 Question
- 13.7680.5 – GFCI and SPGFCI Protection
- 13.8680.5 – GFCI and SPGFCI Protection1 Question
- 13.9690.43 – Equipment Grounding and Bonding
- 13.10690.43 – Equipment Grounding and Bonding1 Question
- 13.11690.31 – Wiring Methods
- 13.12690.31 – Wiring Methods1 Question
- 13.13680.26(B)(2) – Equipotential Bonding – Perimeter Surfaces
- 13.14680.26(B)(2) – Equipotential Bonding – Perimeter Surfaces1 Question
- 13.15680.21(D) – Pool Pump Motor Replacement
- 13.16680.21(D) – Pool Pump Motor Replacement1 Question
- 13.17680.54(C) – Equipotential Bonding of Splash Pads
- 13.18680.54(C) – Equipotential Bonding of Splash Pads1 Question
- NEC 2023 - Grounding and Bonding - NEC Courses Article 800 Series2
- NEC 2023 - Grounding and Bonding - NEC Courses Article 300 Series2
- NEC 2023 - Theory and Calculations - NEC Courses Article 200 Series32
- 16.1210.19 Conductors – Minimum Ampacity and Size
- 16.2210.19 Conductors – Minimum Ampacity and Size1 Question
- 16.3210.23 Permissible Loads, Multiple-Outlet Branch Circuits
- 16.4210.23 Permissible Loads, Multiple-Outlet Branch Circuits1 Question
- 16.5210.70 Lighting Outlets Required
- 16.6210.70 Lighting Outlets Required1 Question
- 16.7220.110 Receptacle Loads
- 16.8220.110 Receptacle Loads1 Question
- 16.9220.120 Marinas, Boatyards, Floating Buildings, And Commercial and Noncommercial Docking Facilities
- 16.10220.120 Marinas, Boatyards, Floating Buildings, And Commercial and Noncommercial Docking Facilities1 Question
- 16.11220.57 Electric Vehicle Supply Equipment
- 16.12220.57 Electric Vehicle Supply Equipment1 Question
- 16.13220.70 Energy Management Systems (EMSs)
- 16.14220.70 Energy Management Systems (EMSs)1 Question
- 16.15215.15 Barriers
- 16.16215.15 Barriers1 Question
- 16.17210.52(C) Island and Peninsular Countertops and Work Surfaces
- 16.18210.52(C) Island and Peninsular Countertops and Work Surfaces1 Question
- 16.19220.5(C) Floor Areas
- 16.20220.5(C) Floor Areas1 Question
- 16.21230.71(B) Two to Six Disconnecting Means
- 16.22230.71(B) Two to Six Disconnecting Means1 Question
- 16.23240.11 Selective Coordination
- 16.24240.11 Selective Coordination1 Question
- 16.25240.4(B) Overcurrent Devices Rated 800 Amperes or Less
- 16.26240.4(B) Overcurrent Devices Rated 800 Amperes or Less1 Question
- 16.27240.4(D)(3) 14 AWG Copper-Clad Aluminum
- 16.28240.4(D)(3) 14 AWG Copper-Clad Aluminum1 Question
- 16.29Table 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers
- 16.30Table 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers1 Question
- 16.31Table 240.6(D) Remotely Accessible Adjustable-Trip Circuit Breakers
- 16.32Table 240.6(D) Remotely Accessible Adjustable-Trip Circuit Breakers1 Question
- NEC 2023 - Theory and Calculations - NEC Courses Article 300 Series6
- NEC 2023 - Theory and Calculations - NEC Courses Article 400 Series10
- 18.1404.14 Rating and Use of Switches
- 18.2404.14 Rating and Use of Switches1 Question
- 18.3406.3 Receptacle Rating and Type
- 18.4406.3 Receptacle Rating and Type1 Question
- 18.5422.18 Ceiling-Suspended (Paddle) Fans
- 18.6422.18 Ceiling-Suspended (Paddle) Fans1 Question
- 18.7430.6 Conductor Ampacity and Motor Rating Determination
- 18.8430.6 Conductor Ampacity and Motor Rating Determination1 Question
- 18.9440.8 Single Machine and Location
- 18.10440.8 Single Machine and Location1 Question
- NEC 2023 - Theory and Calculations - NEC Courses Article 600 Series4
- NEC 2023 - Theory and Calculations - NEC Courses Article 700 Series10
- 20.1700.4 Capacity and Rating
- 20.2700.4 Capacity and Rating1 Question
- 20.3705.12(A) Feeders and Feeder Taps
- 20.4705.12(A) Feeders and Feeder Taps1 Question
- 20.5726.144 Ampacity
- 20.6726.144 Ampacity1 Question
- 20.7700.12(C) Supply Duration
- 20.8700.12(C) Supply Duration1 Question
- 20.9750.30(C) Capacity of Branch Circuit, Feeder, or Service