Covers the 2026 National Electrical Code changes to wiring methods and equipment, beginning with the restructured Article 300 rules for securing and supporting, conductor protection, and the 360-degree bend limit, and the parallel provisions in Article 305 for systems over 1000 V AC and 1500 V DC. Participants examine the relocated receptacle and switch requirements across Article 406, including tamper-resistant receptacles and switch faceplates, the reconditioned equipment and busbar rules in Article 408, SCCR marking for industrial control panels, and the revised listing, disconnect, and labeling requirements for electric vehicle supply equipment under Article 625.
The course then addresses special conditions: bonding, gas detection, and the tabulated wiring methods for hazardous locations under Articles 500 and 501, the relocated area classification rules for commercial garages, bulk storage plants, and spray areas, the restructured temporary installation requirements in Article 590, and the listing, bonding, and GFCI changes for pools and spas in Article 680. The final section covers the North Dakota Wiring Standards, including the 5% voltage-drop limit, minimum 100-ampere services, egress and emergency lighting, the ND AFCI and GFCI exceptions, and hazardous locations in oilfields and grain elevators.
Learning objectives
- Identify the relocated securing, supporting, and conductor protection requirements in Articles 300 and 305, including the 360-degree bend limit.
- Locate the receptacle, switch, and faceplate requirements moved within Article 406, and the reconditioned equipment and busbar rules in Article 408.
- Apply the 2026 listing, disconnect, and labeling requirements for electric vehicle supply equipment under Article 625 and for pool and spa equipment under Article 680.
- Determine area classification and bonding requirements for hazardous locations under Articles 500 through 516, and apply the North Dakota Wiring Standards to voltage drop, service sizing, and egress lighting.
Disclosure of proprietary interest. No instructor, subject-matter expert or content author involved in developing or delivering this course holds any financial or ownership interest in any product, instrument, device or material referenced in it, and none receives any royalty, profit share or other consideration from the promotion or endorsement of any product. This course does not endorse any commercial product or service.
Course Features
- Lectures 94
- Quizzes 94
- Duration 52 weeks
- Skill level All levels
- Language English
- Students 1
- Certificate Yes
- Assessments Self
- Format Audio + Text
- 3 Sections
- 94 Lessons
- NEC 2026: Wiring Methods and Equipment88
- 1.1300.13 – Major Relocation: Securing and Supporting Moves to Section 300.13
- 1.2300.13 – Major Relocation: Securing and Supporting Moves to Section 300.131 Question
- 1.3300.24 – Is the 360-Degree Bend Limit Now a General Requirement?
- 1.4300.24 – Is the 360-Degree Bend Limit Now a General Requirement?1 Question
- 1.5300.4 – Where Did the Nail Plates Go? The Repurposing of Section 300.4
- 1.6300.4 – Where Did the Nail Plates Go? The Repurposing of Section 300.41 Question
- 1.7300.5 – Major Restructuring: Section 300.5 is Now “Conductors”
- 1.8300.5 – Major Restructuring: Section 300.5 is Now “Conductors”1 Question
- 1.9300.6 – Where Did the Physical Damage Rules Go? (Section 300.6)
- 1.10300.6 – Where Did the Physical Damage Rules Go? (Section 300.6)1 Question
- 1.11300.9 – Managing Temperature Changes: Condensation and Expansion
- 1.12300.9 – Managing Temperature Changes: Condensation and Expansion1 Question
- 1.13305.14 – Where Did the Physical Damage Protection Rules Go? (Systems over 1000VAC/1500VDC)
- 1.14305.14 – Where Did the Physical Damage Protection Rules Go? (Systems over 1000VAC/1500VDC)1 Question
- 1.15305.16 – Where Did the Corrosion Protection Rules Go? (Systems over 1000VAC/1500VDC)
- 1.16305.16 – Where Did the Corrosion Protection Rules Go? (Systems over 1000VAC/1500VDC)1 Question
- 1.17305.17 – How are Temperature Changes Handled in the 2026 NEC? (Systems over 1000VAC/1500VDC)
- 1.18305.17 – How are Temperature Changes Handled in the 2026 NEC? (Systems over 1000VAC/1500VDC)1 Question
- 1.19305.21 – New General Requirements for Securing and Supporting Wiring Methods (Systems over 1000VAC/1500VDC)
- 1.20305.21 – New General Requirements for Securing and Supporting Wiring Methods (Systems over 1000VAC/1500VDC)1 Question
- 1.21305.29 – Where Did Vertical Raceway Supports Go? (New Section 305.29)
- 1.22305.29 – Where Did Vertical Raceway Supports Go? (New Section 305.29)1 Question
- 1.23305.32 – Wiring in Ducts and Plenums (Section 305.32) (Systems over 1000VAC/1500VDC)
- 1.24305.32 – Wiring in Ducts and Plenums (Section 305.32) (Systems over 1000VAC/1500VDC)1 Question
- 1.25310.5 – New Minimum Conductor Sizes and Section Relocation
- 1.26310.5 – New Minimum Conductor Sizes and Section Relocation1 Question
- 1.27312.11 – Where did the Rules for Splices in Switch Enclosures Go?
- 1.28312.11 – Where did the Rules for Splices in Switch Enclosures Go?1 Question
- 1.29314.27 – Outlet Box Support and Fan Box Locations: 2026 Revisions
- 1.30314.27 – Outlet Box Support and Fan Box Locations: 2026 Revisions1 Question
- 1.31342.30 – Updates to IMC Securing and Supporting References
- 1.32342.30 – Updates to IMC Securing and Supporting References1 Question
- 1.33400.10 – Clarifying References for Flexible Cord Requirements
- 1.34400.10 – Clarifying References for Flexible Cord Requirements1 Question
- 1.35402.13 – Where Did Table 402.3 Go? New Location for Fixture Wire Types
- 1.36402.13 – Where Did Table 402.3 Go? New Location for Fixture Wire Types1 Question
- 1.37404.2 – Where Did the “Neutral at the Switch” Rule Go? (New Listing Requirements)
- 1.38404.2 – Where Did the “Neutral at the Switch” Rule Go? (New Listing Requirements)1 Question
- 1.39406.12 – Where Did General Installation Requirements for receptacles, cord connectors, and attachment plugs Go?
- 1.40406.12 – Where Did General Installation Requirements for receptacles, cord connectors, and attachment plugs Go?1 Question
- 1.41406.14 – Where Did Receptacle Mounting Rules Go in the 2026 NEC?
- 1.42406.14 – Where Did Receptacle Mounting Rules Go in the 2026 NEC?1 Question
- 1.43406.16 – Did Receptacle Faceplate Rules Move?
- 1.44406.16 – Did Receptacle Faceplate Rules Move?1 Question
- 1.45406.18 – Where did the rules for Attachment Plugs and Connectors go in 2026?
- 1.46406.18 – Where did the rules for Attachment Plugs and Connectors go in 2026?1 Question
- 1.47406.19 – Where Did Grounding-Type Receptacle Rules Go? (Relocation to 406.19)
- 1.48406.19 – Where Did Grounding-Type Receptacle Rules Go? (Relocation to 406.19)1 Question
- 1.49406.26 – Where are Tamper-Resistant Receptacles Now Required?
- 1.50406.26 – Where are Tamper-Resistant Receptacles Now Required?1 Question
- 1.51406.28 – Where Did Single-Pole Separable Connectors Go? Understanding New Section 406.28
- 1.52406.28 – Where Did Single-Pole Separable Connectors Go? Understanding New Section 406.281 Question
- 1.53406.30 – Where Did the Neutral Rule Go? Relocation of Switch Connections
- 1.54406.30 – Where Did the Neutral Rule Go? Relocation of Switch Connections1 Question
- 1.55406.38 – Where Did the Switch Grouping Rule Go? Understanding New Section 406.38
- 1.56406.38 – Where Did the Switch Grouping Rule Go? Understanding New Section 406.381 Question
- 1.57406.40 – Switch Faceplates Relocated and Expanded to Include Dimmers and Control Switches
- 1.58406.40 – Switch Faceplates Relocated and Expanded to Include Dimmers and Control Switches1 Question
- 1.59406.9 – 406.9 includes switches now?
- 1.60406.9 – 406.9 includes switches now?1 Question
- 1.61408.10 – Where Did the Busbar Rules Go? A Move to 408.10
- 1.62408.10 – Where Did the Busbar Rules Go? A Move to 408.101 Question
- 1.63408.3 – New Rules for Reconditioned Equipment (Section 408.3)
- 1.64408.3 – New Rules for Reconditioned Equipment (Section 408.3)1 Question
- 1.65409.110 – SCCR Visibility and Marking Updates for Industrial Control Panels
- 1.66409.110 – SCCR Visibility and Marking Updates for Industrial Control Panels1 Question
- 1.67410.116 – Recessed Luminaire Clearances and Fire-Rated Installations
- 1.68410.116 – Recessed Luminaire Clearances and Fire-Rated Installations1 Question
- 1.69410.64 – Can Luminaires Be Used as Raceways?
- 1.70410.64 – Can Luminaires Be Used as Raceways?1 Question
- 1.71424.19 – How Have Disconnecting Means for Space Heating Changed?
- 1.72424.19 – How Have Disconnecting Means for Space Heating Changed?1 Question
- 1.73426.60 – How Does the 2026 NEC Address Conductive Pavement Heating?
- 1.74426.60 – How Does the 2026 NEC Address Conductive Pavement Heating?1 Question
- 1.75426.62 – Where are Conductive Pavement Heating Systems Prohibited?
- 1.76426.62 – Where are Conductive Pavement Heating Systems Prohibited?1 Question
- 1.77625.2 – How Have Listing Requirements for EV Equipment Changed?
- 1.78625.2 – How Have Listing Requirements for EV Equipment Changed?1 Question
- 1.79625.40 – Did the Exception for EV Branch Circuits Change in 2026?
- 1.80625.40 – Did the Exception for EV Branch Circuits Change in 2026?1 Question
- 1.81625.43 – Emergency Shutoffs and Expanded Disconnect Rules for EVSE
- 1.82625.43 – Emergency Shutoffs and Expanded Disconnect Rules for EVSE1 Question
- 1.83625.44 – New Plug Ratings and Voltage Options for EV Chargers
- 1.84625.44 – New Plug Ratings and Voltage Options for EV Chargers1 Question
- 1.85625.5 – Are You Labeling EVSE Correctly Under the New 2026 Rules?
- 1.86625.5 – Are You Labeling EVSE Correctly Under the New 2026 Rules?1 Question
- 1.87706.31 – Did the 2026 NEC Remove the Current-Limiting Requirement for ESS?
- 1.88706.31 – Did the 2026 NEC Remove the Current-Limiting Requirement for ESS?1 Question
- NEC 2026: Special Conditions40
- 2.1500.30 – How Does the New Section 500.30 Standardize Bonding in Hazardous Locations?
- 2.2500.30 – How Does the New Section 500.30 Standardize Bonding in Hazardous Locations?1 Question
- 2.3500.7 – Does Gas Detection Replace Purge Cycles in Hazardous Locations?
- 2.4500.7 – Does Gas Detection Replace Purge Cycles in Hazardous Locations?1 Question
- 2.5500.8 – Clarifying Equipment vs. Installation in Hazardous Locations
- 2.6500.8 – Clarifying Equipment vs. Installation in Hazardous Locations1 Question
- 2.7501.10 – How 501.10 Transformed Wiring Methods into Tables
- 2.8501.10 – How 501.10 Transformed Wiring Methods into Tables1 Question
- 2.9501.15 – Clarifying Boundary Seals and Cable Types in Hazardous Locations
- 2.10501.15 – Clarifying Boundary Seals and Cable Types in Hazardous Locations1 Question
- 2.11511.5 – Where did the Area Classification rules for Commercial Garages go?
- 2.12511.5 – Where did the Area Classification rules for Commercial Garages go?1 Question
- 2.13511.6 – How Have Commercial Garage Rules Changed for 2026?
- 2.14511.6 – How Have Commercial Garage Rules Changed for 2026?1 Question
- 2.15512.5 – How are Hazardous Locations Classified for Cannabis Oil Equipment?
- 2.16512.5 – How are Hazardous Locations Classified for Cannabis Oil Equipment?1 Question
- 2.17514.5 – Where Did Classification Go? Relocation of Hazardous Locations
- 2.18514.5 – Where Did Classification Go? Relocation of Hazardous Locations1 Question
- 2.19515.5 – Relocation of Classification Rules for Bulk Storage Plants
- 2.20515.5 – Relocation of Classification Rules for Bulk Storage Plants1 Question
- 2.21516.8 – Spray Area Safety: Renumbering and Static Grounding Requirements
- 2.22516.8 – Spray Area Safety: Renumbering and Static Grounding Requirements1 Question
- 2.23516.9 – New Location for Wiring Rules Above Spray Areas
- 2.24516.9 – New Location for Wiring Rules Above Spray Areas1 Question
- 2.25590.4 – Where Did the Rules Go? Section 590.4 Completely Restructured
- 2.26590.4 – Where Did the Rules Go? Section 590.4 Completely Restructured1 Question
- 2.27590.6 – Major Restructuring: General Rules Move to 590.6
- 2.28590.6 – Major Restructuring: General Rules Move to 590.61 Question
- 2.29625.17 – EVSE Cords: “Hand Fastened” Terminology and Ampacity Clarity
- 2.30625.17 – EVSE Cords: “Hand Fastened” Terminology and Ampacity Clarity1 Question
- 2.31680.2 – Is Listing Now Mandatory for All Pool and Spa Equipment?
- 2.32680.2 – Is Listing Now Mandatory for All Pool and Spa Equipment?1 Question
- 2.33680.23 – Clarified Bonding Requirements for Wet-Niche Luminaires
- 2.34680.23 – Clarified Bonding Requirements for Wet-Niche Luminaires1 Question
- 2.35680.26 – New Materials and Listing Extensions for Pool Bonding
- 2.36680.26 – New Materials and Listing Extensions for Pool Bonding1 Question
- 2.37680.42 – How have the references in Section 680.42 changed for 2026?
- 2.38680.42 – How have the references in Section 680.42 changed for 2026?1 Question
- 2.39680.5 – How Have GFCI Requirements for 3-Phase Pool Equipment Changed?
- 2.40680.5 – How Have GFCI Requirements for 3-Phase Pool Equipment Changed?1 Question
- North Dakota Laws, Rules and Wiring Standards (2024)60
- 3.1ND Laws/Rules: Capacity and the 5% Voltage-Drop Limit
- 3.2ND Laws/Rules: Capacity and the 5% Voltage-Drop Limit1 Question
- 3.3ND Laws/Rules: Listing, PE Evaluations, Schools, Hospitals, and Energy Codes
- 3.4ND Laws/Rules: Listing, PE Evaluations, Schools, Hospitals, and Energy Codes1 Question
- 3.5ND Laws/Rules: Water Wells, Aluminum Limits, and Remodels
- 3.6ND Laws/Rules: Water Wells, Aluminum Limits, and Remodels1 Question
- 3.7ND Laws/Rules: Handling Water-Damaged Electrical Equipment
- 3.8ND Laws/Rules: Handling Water-Damaged Electrical Equipment1 Question
- 3.9ND Laws/Rules: Exit Sign Marking Requirements
- 3.10ND Laws/Rules: Exit Sign Marking Requirements1 Question
- 3.11ND Laws/Rules: Means of Egress – Illumination & Emergency Lighting
- 3.12ND Laws/Rules: Means of Egress – Illumination & Emergency Lighting1 Question
- 3.13ND Laws/Rules: Occupancy Classification for Egress
- 3.14ND Laws/Rules: Occupancy Classification for Egress1 Question
- 3.15ND Laws/Rules: Occupant Load & Building-Classification
- 3.16ND Laws/Rules: Occupant Load & Building-Classification1 Question
- 3.17ND Laws/Rules: Smoke and Heat Alarm Requirements
- 3.18ND Laws/Rules: Smoke and Heat Alarm Requirements1 Question
- 3.19ND Laws/Rules: CO Alarms, ESS Protection & Fire-Alarm Systems
- 3.20ND Laws/Rules: CO Alarms, ESS Protection & Fire-Alarm Systems1 Question
- 3.21ND Laws/Rules: Load Balancing & Dwelling Heating Circuits
- 3.22ND Laws/Rules: Load Balancing & Dwelling Heating Circuits1 Question
- 3.23ND Laws/Rules: Small-Appliance Branch Circuits for Public and Dwelling Kitchens
- 3.24ND Laws/Rules: Small-Appliance Branch Circuits for Public and Dwelling Kitchens1 Question
- 3.25ND Laws/Rules: Bathroom Circuits & Pump/Garage GFCI Rules
- 3.26ND Laws/Rules: Bathroom Circuits & Pump/Garage GFCI Rules1 Question
- 3.27ND Laws/Rules: ND AFCI & GFCI Appliance Exceptions
- 3.28ND Laws/Rules: ND AFCI & GFCI Appliance Exceptions1 Question
- 3.29ND Laws/Rules: Corridor Outlets, Small-Building & Island Receptacles
- 3.30ND Laws/Rules: Corridor Outlets, Small-Building & Island Receptacles1 Question
- 3.31ND Laws/Rules: Feeder Surge-Protection Exemptions
- 3.32ND Laws/Rules: Feeder Surge-Protection Exemptions1 Question
- 3.33ND Laws/Rules: Service Mast, Outside Switch, and Single-Location Rules
- 3.34ND Laws/Rules: Service Mast, Outside Switch, and Single-Location Rules1 Question
- 3.35ND Laws/Rules: Minimum 100-Ampere Service Requirements
- 3.36ND Laws/Rules: Minimum 100-Ampere Service Requirements1 Question
- 3.37ND Laws/Rules: Panel-Space Requirements & Electric-Heat Sizing
- 3.38ND Laws/Rules: Panel-Space Requirements & Electric-Heat Sizing1 Question
- 3.39ND Laws/Rules: Overcurrent Protection: Height and Prohibited Locations
- 3.40ND Laws/Rules: Overcurrent Protection: Height and Prohibited Locations1 Question
- 3.41ND Laws/Rules: Motor Flex-Conduit Bonding & Parallel EGC
- 3.42ND Laws/Rules: Motor Flex-Conduit Bonding & Parallel EGC1 Question
- 3.43ND Laws/Rules: Grounding Outdoor Lighting Standards & GEC Connection
- 3.44ND Laws/Rules: Grounding Outdoor Lighting Standards & GEC Connection1 Question
- 3.45ND Laws/Rules: Agricultural Buildings & Raceway Restrictions
- 3.46ND Laws/Rules: Agricultural Buildings & Raceway Restrictions1 Question
- 3.47ND Laws/Rules: Corrosive Locations & Metal Wiring Methods in Health Care & Assembly
- 3.48ND Laws/Rules: Corrosive Locations & Metal Wiring Methods in Health Care & Assembly1 Question
- 3.49ND Laws/Rules: Boxes and Fittings: Extension Rings and Enclosure Requirements
- 3.50ND Laws/Rules: Boxes and Fittings: Extension Rings and Enclosure Requirements1 Question
- 3.51ND Laws/Rules: Fuel-Fired Furnace Cords and Receptacles
- 3.52ND Laws/Rules: Fuel-Fired Furnace Cords and Receptacles1 Question
- 3.53ND Laws/Rules: Hazardous Locations: Classification, Oilfields, and Grain Elevators
- 3.54ND Laws/Rules: Hazardous Locations: Classification, Oilfields, and Grain Elevators1 Question
- 3.55ND Laws/Rules: Service Equipment on Manufactured Homes
- 3.56ND Laws/Rules: Service Equipment on Manufactured Homes1 Question
- 3.57ND Laws/Rules: EV Charging Systems: Overcurrent Protection & Setting Labeling
- 3.58ND Laws/Rules: EV Charging Systems: Overcurrent Protection & Setting Labeling1 Question
- 3.59ND Laws/Rules: Voltage-Drop Calculations & Electrical Fundamentals
- 3.60ND Laws/Rules: Voltage-Drop Calculations & Electrical Fundamentals1 Question