The curriculum features a core 8-hour review of the National Electrical Code (NEC) 2023 changes. You will also sharpen your technical expertise with targeted 4-hour modules on Wiring Methods, Grounding and Bonding, and Theory and Calculations, covering the essential skills needed for modern electrical installations.
In addition to technical training, the package includes a dedicated 4-hour module on Electrical Industry Safety.
Disclosure of proprietary interest. No instructor, subject-matter expert or content author involved in developing or delivering this course holds any financial or ownership interest in any product, instrument, device or material referenced in it, and none receives any royalty, profit share or other consideration from the promotion or endorsement of any product. This course does not endorse any commercial product or service.
Course Features
- Lectures 223
- Quizzes 222
- Duration 52 weeks
- Skill level All levels
- Language English
- Students 28
- Certificate Yes
- Assessments Self
- Format Text
- 27 Sections
- 223 Lessons
- NEC 2023 - Code Update (CH 1-8) - NEC Article 100 Series15
- 1.1Course Orientation
- 1.2110.20 – Reconditioned Equipment
- 1.3110.20 – Reconditioned Equipment1 Question
- 1.4110.21 – Markings
- 1.5110.21 – Markings1 Question
- 1.6110.16(B) – Arc-Flash Hazard Warnings – Service Equipment
- 1.7110.16(B) – Arc-Flash Hazard Warnings – Service Equipment1 Question
- 1.8110.2(B) When Required
- 1.9110.2(B) When Required1 Question
- 1.10110.22(A) – Identification of Disconnecting Means
- 1.11110.22(A) – Identification of Disconnecting Means1 Question
- 1.12120.6 Process for Establishing and Verifying an Electrically Safe Work Condition
- 1.13120.6 Process for Establishing and Verifying an Electrically Safe Work Condition1 Question
- 1.14130.7(C)(5) Hearing Protection
- 1.15130.7(C)(5) Hearing Protection1 Question
- NEC 2023 - Code Update (CH 1-8) - NEC Article 200 Series20
- 2.1210.17 Guest Rooms and Guest Suites
- 2.2210.17 Guest Rooms and Guest Suites1 Question
- 2.3215.18 Surge Protection
- 2.4215.18 Surge Protection1 Question
- 2.5225.41 Emergency Disconnects
- 2.6225.41 Emergency Disconnects1 Question
- 2.7230.67 Surge Protection
- 2.8230.67 Surge Protection1 Question
- 2.9Article 235 – Branch Circuits, Feeders and Services over 1000 Volts AC, 1500 Volts DC, Nominal
- 2.10Article 235 – Branch Circuits, Feeders and Services over 1000 Volts AC, 1500 Volts DC, Nominal1 Question
- 2.11240.2 Reconditioned Equipment
- 2.12240.2 Reconditioned Equipment1 Question
- 2.13Article 245 – Overcurrent Protection over 1000 Volts AC, 1500 Volts DC
- 2.14Article 245 – Overcurrent Protection over 1000 Volts AC, 1500 Volts DC1 Question
- 2.15210.11(C)(4) Garage Branch Circuits
- 2.16210.11(C)(4) Garage Branch Circuits1 Question
- 2.17210.52(G) Basements, Garages, and Accessory Buildings
- 2.18210.52(G) Basements, Garages, and Accessory Buildings1 Question
- 2.19240.24(A) and (E) – Location in or on Premises
- 2.20240.24(A) and (E) – Location in or on Premises1 Question
- NEC 2023 - Code Update (CH 1-8) - NEC Article 300 Series22
- 3.1315.17 Marking for Type Medium Voltage Cable Joints, and Terminations
- 3.2315.17 Marking for Type Medium Voltage Cable Joints, and Terminations1 Question
- 3.3315.32 Uses Permitted for Type Medium Voltage Cables, Cable Joints, and Terminations
- 3.4315.32 Uses Permitted for Type Medium Voltage Cables, Cable Joints, and Terminations1 Question
- 3.5369.10 Uses Permitted for Insulated Bus Pipe (IBP) Systems
- 3.6369.10 Uses Permitted for Insulated Bus Pipe (IBP) Systems1 Question
- 3.7369.120 Marking Insulated Bus Pipe (IBP) Systems
- 3.8369.120 Marking Insulated Bus Pipe (IBP) Systems1 Question
- 3.9371.17 Overcurrent Protection of Flexible Bus System
- 3.10371.17 Overcurrent Protection of Flexible Bus System1 Question
- 3.11371.30 Securing and Supporting
- 3.12371.30 Securing and Supporting1 Question
- 3.13398.15 Exposed Work
- 3.14398.15 Exposed Work1 Question
- 3.15300.3 (C) Conductors of Different Systems
- 3.16300.3 (C) Conductors of Different Systems1 Question
- 3.17300.11(C) Raceways Used as Means of Support
- 3.18300.11(C) Raceways Used as Means of Support1 Question
- 3.19320.3(A)(1) Electrical Hazard Thresholds.
- 3.20320.3(A)(1) Electrical Hazard Thresholds.10 Minutes1 Question
- 3.21371.10 and 371.12 Uses Permitted and Not Permitted
- 3.22371.10 and 371.12 Uses Permitted and Not Permitted1 Question
- NEC 2023 - Code Update (CH 1-8) - NEC Article 400 Series22
- 4.1404.16 Reconditioned Equipment
- 4.2404.16 Reconditioned Equipment1 Question
- 4.3406.12 Tamper-Resistant Receptacles.
- 4.4406.12 Tamper-Resistant Receptacles.1 Question
- 4.5408.4 Descriptions Required
- 4.6408.4 Descriptions Required1 Question
- 4.7408.9 Replacement Panelboards
- 4.8408.9 Replacement Panelboards1 Question
- 4.9409.70 Surge Protection
- 4.10409.70 Surge Protection1 Question
- 4.11410.197 Germicidal Irradiation Systems
- 4.12410.197 Germicidal Irradiation Systems1 Question
- 4.13410.71(1) General
- 4.14410.71(1) General1 Question
- 4.15430.2 Reconditioned Motors
- 4.16430.2 Reconditioned Motors1 Question
- 4.17445.19 Emergency Shutdown of Prime Mover
- 4.18445.19 Emergency Shutdown of Prime Mover1 Question
- 4.19470.2 Reconditioned Equipment
- 4.20470.2 Reconditioned Equipment1 Question
- 4.21406.6(D) Receptacle Faceplate (Cover Plates) With Integral Night Light and/or USB Charger
- 4.22406.6(D) Receptacle Faceplate (Cover Plates) With Integral Night Light and/or USB Charger1 Question
- NEC 2023 - Code Update (CH 1-8) - NEC Article 500 Series14
- 5.1512.13 Wiring Installed Above Hazardous (Classified) Locations
- 5.2512.13 Wiring Installed Above Hazardous (Classified) Locations1 Question
- 5.3517.30(B) Power Sources for the EES
- 5.4517.30(B) Power Sources for the EES1 Question
- 5.5518.5 Supply
- 5.6518.5 Supply1 Question
- 5.7547.26 Physical Protection
- 5.8547.26 Physical Protection1 Question
- 5.9500.5 (D) Classifications of Locations
- 5.10500.5 (D) Classifications of Locations1 Question
- 5.11512.3(A) Cannabis Oil Equipment and Systems Other Than Booths
- 5.12512.3(A) Cannabis Oil Equipment and Systems Other Than Booths1 Question
- 5.13512.3(B) Cannabis Oil Booths
- 5.14512.3(B) Cannabis Oil Booths1 Question
- NEC 2023 - Code Update (CH 1-8) - NEC Article 600 Series26
- 6.1600.35 – Retrofit Kits
- 6.2600.35 – Retrofit Kits1 Question
- 6.3625.40 Electric Vehicle Branch Circuit
- 6.4625.40 Electric Vehicle Branch Circuit1 Question
- 6.5625.49 – Island Mode
- 6.6625.49 – Island Mode1 Question
- 6.7625.6 – Listed
- 6.8625.6 – Listed1 Question
- 6.9630.8 – Electric Welders
- 6.10630.8 – Electric Welders1 Question
- 6.11690.1 New illustration to help understand PV components
- 6.12690.1 New illustration to help understand PV components1 Question
- 6.13690.12 – Rapid Shutdown Requirements
- 6.14690.12 – Rapid Shutdown Requirements1 Question
- 6.15690.15 – Disconnecting Means for Isolating Photovoltaic Equipment
- 6.16690.15 – Disconnecting Means for Isolating Photovoltaic Equipment1 Question
- 6.17690.56 – Identification of Power Sources
- 6.18690.56 – Identification of Power Sources1 Question
- 6.19691.4 Special Requirements for Large-Scale PV Electric Supply Stations
- 6.20691.4 Special Requirements for Large-Scale PV Electric Supply Stations1 Question
- 6.21600.5(A) – Branch Circuits
- 6.22600.5(A) – Branch Circuits1 Question
- 6.23620.12(A) – Traveling Cables
- 6.24620.12(A) – Traveling Cables1 Question
- 6.25690.4(G) – PV Equipment Floating on Bodies of Water
- 6.26690.4(G) – PV Equipment Floating on Bodies of Water1 Question
- NEC 2023 - Code Update (CH 1-8) - NEC Article 700 Series28
- 7.1700.11 Wiring, Class-2-Powered Emergency Lighting Systems
- 7.2700.11 Wiring, Class-2-Powered Emergency Lighting Systems1 Question
- 7.3700.12(E) Stored-Energy Power Supply Systems (SEPSS)
- 7.4700.12(E) Stored-Energy Power Supply Systems (SEPSS)1 Question
- 7.5700.27 Class 2 Powered Emergency Lighting Systems
- 7.6700.27 Class 2 Powered Emergency Lighting Systems1 Question
- 7.7700.32 Selective Coordination
- 7.8700.32 Selective Coordination1 Question
- 7.9700.3(F) Temporary Source of Power for Maintenance or Repair of the Alternate Source of Power
- 7.10700.3(F) Temporary Source of Power for Maintenance or Repair of the Alternate Source of Power1 Question
- 7.11701.10 Wiring Legally Required Standby Systems
- 7.12701.10 Wiring Legally Required Standby Systems1 Question
- 7.13701.4(C) Load Management
- 7.14701.4(C) Load Management1 Question
- 7.15705.10 Identification of Power Sources
- 7.16705.10 Identification of Power Sources1 Question
- 7.17706.7 Commissioning and Maintenance
- 7.18706.7 Commissioning and Maintenance1 Question
- 7.19726.121 Power Sources for Class 4 Circuits
- 7.20726.121 Power Sources for Class 4 Circuits1 Question
- 7.21726.122 Class 4 Loads
- 7.22726.122 Class 4 Loads1 Question
- 7.23726.124 Class 4 Marking
- 7.24726.124 Class 4 Marking1 Question
- 7.25726.130 Terminals and Connectors
- 7.26726.130 Terminals and Connectors1 Question
- 7.27700.12(G) Microgrid Systems
- 7.28700.12(G) Microgrid Systems1 Question
- NEC 2023 - Code Update (CH 1-8) - NEC Article 800 Series4
- NEC 2023 - Grounding and Bonding - NEC Article 100 Series4
- NEC 2023 - Grounding and Bonding - NEC Article 200 Series22
- 10.1250.130 – Equipment Grounding Conductor Connections
- 10.2250.130 – Equipment Grounding Conductor Connections1 Question
- 10.3250.140 – Frames of Ranges and Clothes Dryers
- 10.4250.140 – Frames of Ranges and Clothes Dryers1 Question
- 10.5250.148 – Continuity of Equipment Grounding Conductors and Attachment in Boxes
- 10.6250.148 – Continuity of Equipment Grounding Conductors and Attachment in Boxes1 Question
- 10.7250.36 – Impedance Grounded Systems
- 10.8250.36 – Impedance Grounded Systems1 Question
- 10.9250.70 – Grounding and Bonding Conductor Connection to Electrodes
- 10.10250.70 – Grounding and Bonding Conductor Connection to Electrodes1 Question
- 10.11210.8(B) Other Than Dwelling Units
- 10.12210.8(B) Other Than Dwelling Units1 Question
- 10.13210.8(F) Outdoor Outlets.
- 10.14210.8(F) Outdoor Outlets.1 Question
- 10.15242.2 and 242.9 – Surge Protective Devices
- 10.16242.2 and 242.9 – Surge Protective Devices1 Question
- 10.17250.24(D) – Grounded Conductor Brought to Service Equipment
- 10.18250.24(D) – Grounded Conductor Brought to Service Equipment1 Question
- 10.19230.85 Emergency Disconnects
- 10.20230.85 Emergency Disconnects1 Question
- 10.21250.64(G) – Enclosures with Ventilation Openings
- 10.22250.64(G) – Enclosures with Ventilation Openings1 Question
- NEC 2023 - Grounding and Bonding - NEC Article 300 Series2
- NEC 2023 - Grounding and Bonding - NEC Article 400 Series6
- 12.1410.184 Ground-Fault Circuit-Interrupter (GFCI) Protection and Special Purpose Ground-Fault Circuit-Interrupter (SPGFCI) Protection
- 12.2410.184 Ground-Fault Circuit-Interrupter (GFCI) Protection and Special Purpose Ground-Fault Circuit-Interrupter (SPGFCI) Protection1 Question
- 12.3406.4(D) Receptacle Replacements
- 12.4406.4(D) Receptacle Replacements1 Question
- 12.5406.9 (C) Bathtub and Shower Space
- 12.6406.9 (C) Bathtub and Shower Space1 Question
- NEC 2023 - Grounding and Bonding - NEC Article 500 Series18
- 13.1501.30 Grounding and Bonding
- 13.2501.30 Grounding and Bonding1 Question
- 13.3502.30 Grounding and Bonding
- 13.4502.30 Grounding and Bonding1 Question
- 13.5511.7(A) Wiring in Spaces Above Hazardous (Classified) Locations
- 13.6511.7(A) Wiring in Spaces Above Hazardous (Classified) Locations1 Question
- 13.7517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care Spaces
- 13.8517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care Spaces1 Question
- 13.9517.14 Panelboard Bonding
- 13.10517.14 Panelboard Bonding1 Question
- 13.11547.44 Equipotential Planes and Bonding of Equipotential Planes
- 13.12547.44 Equipotential Planes and Bonding of Equipotential Planes1 Question
- 13.13551.3 Electrical Datum Plane Distances
- 13.14551.3 Electrical Datum Plane Distances1 Question
- 13.15551.40 120-Volt or 120/240-Volt, Nominal, Systems
- 13.16551.40 120-Volt or 120/240-Volt, Nominal, Systems1 Question
- 13.17555.14 Equipotential Planes and Bonding of Equipotential Planes
- 13.18555.14 Equipotential Planes and Bonding of Equipotential Planes1 Question
- NEC 2023 - Grounding and Bonding - NEC Article 600 Series18
- 14.1620.6 – GFCI Protection for Personnel
- 14.2620.6 – GFCI Protection for Personnel1 Question
- 14.3680.32 – GFCI and SPGFCI Protection
- 14.4680.32 – GFCI and SPGFCI Protection1 Question
- 14.5680.44 – GFCI & SPGFCI Protection
- 14.6680.44 – GFCI & SPGFCI Protection1 Question
- 14.7680.5 – GFCI and SPGFCI Protection
- 14.8680.5 – GFCI and SPGFCI Protection1 Question
- 14.9690.43 – Equipment Grounding and Bonding
- 14.10690.43 – Equipment Grounding and Bonding1 Question
- 14.11690.31 – Wiring Methods
- 14.12690.31 – Wiring Methods1 Question
- 14.13680.26(B)(2) – Equipotential Bonding – Perimeter Surfaces
- 14.14680.26(B)(2) – Equipotential Bonding – Perimeter Surfaces1 Question
- 14.15680.21(D) – Pool Pump Motor Replacement
- 14.16680.21(D) – Pool Pump Motor Replacement1 Question
- 14.17680.54(C) – Equipotential Bonding of Splash Pads
- 14.18680.54(C) – Equipotential Bonding of Splash Pads1 Question
- NEC 2023 - Grounding and Bonding - NEC Article 800 Series2
- NEC 2023 - Wiring Methods - NEC Article 100 Series12
- 16.1110.17 – Servicing and Maintenance of Equipment
- 16.2110.17 – Servicing and Maintenance of Equipment1 Question
- 16.3110.26 – Spaces About Electrical Equipment
- 16.4110.26 – Spaces About Electrical Equipment1 Question
- 16.5110.29 – In Sight From
- 16.6110.29 In Sight From1 Question
- 16.7110.3 – Examination, Identification, Installation, Use, and Listing (Product Certification) of Equipment.
- 16.8110.3 – Examination, Identification, Installation, Use, and Listing (Product Certification) of Equipment.1 Question
- 16.9110.3(I) Job Safety Planning and Job Briefing
- 16.10110.3(I) Job Safety Planning and Job Briefing1 Question
- 16.11110.33(A) and 110.34(A)
- 16.12110.33(A) and 110.34(A)1 Question
- NEC 2023 - Wiring Methods - NEC Article 300 Series20
- 17.1312.10 Screws or Other Fasteners
- 17.2312.10 Screws or Other Fasteners1 Question
- 17.3314.16 Box Fill Calculations
- 17.4314.16 Box Fill Calculations1 Question
- 17.5314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible
- 17.6314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible1 Question
- 17.7314.5 Screws or Other Fasteners
- 17.8314.5 Screws or Other Fasteners1 Question
- 17.9320.23 In Accessible Attics
- 17.10320.23 In Accessible Attics1 Question
- 17.11334.10 Uses Permitted
- 17.12334.10 Uses Permitted1 Question
- 17.13334.15 (B) Protection from Physical Damage
- 17.14334.15 (B) Protection from Physical Damage1 Question
- 17.15352.10 Uses Permitted for Rigid Polyvinyl Chloride Conduits
- 17.16352.10 Uses Permitted for Rigid Polyvinyl Chloride Conduits1 Question
- 17.17352.44 Expansion Fittings
- 17.18352.44 Expansion Fittings1 Question
- 17.19356.10 Uses Permitted
- 17.20356.10 Uses Permitted1 Question
- NEC 2023 - Wiring Methods - NEC Article 400 Series12
- 18.1404.30 Switch Enclosures with Doors
- 18.2404.30 Switch Enclosures with Doors1 Question
- 18.3408.38 Enclosure
- 18.4408.38 Enclosure1 Question
- 18.5410.10 Luminaires in Specific Locations
- 18.6410.10 Luminaires in Specific Locations1 Question
- 18.7410.195 Locations Not Permitted
- 18.8410.195 Locations Not Permitted1 Question
- 18.9424.48 Installation of Cables in Walls
- 18.10424.48 Installation of Cables in Walls1 Question
- 18.11424.93 Installation of Electric Radiant Heating Panels and Heating Panel Sets
- 18.12424.93 Installation of Electric Radiant Heating Panels and Heating Panel Sets1 Question
- NEC 2023 - Wiring Methods - NEC Article 500 Series2
- NEC 2023 - Wiring Methods - NEC Article 600 Series12
- 20.1600.6 – Disconnects
- 20.2600.6 – Disconnects1 Question
- 20.3620.36 – Different Systems in One Raceway or Traveling Cable.
- 20.4620.36 – Different Systems in One Raceway or Traveling Cable.1 Question
- 20.5646.19 – Entrance to and Egress from Working Space
- 20.6646.19 – Entrance to and Egress from Working Space1 Question
- 20.7680.12 – Equipment Rooms, Vaults, and Pits
- 20.8680.12 – Equipment Rooms, Vaults, and Pits1 Question
- 20.9680.14 Corrosive Environments
- 20.10680.14 Corrosive Environments1 Question
- 20.11680.41 – Location of Other Equipment
- 20.12680.41 – Location of Other Equipment1 Question
- NEC 2023 - Wiring Methods - NEC Article 800 Series2
- NEC 2023 - Theory and Calculations - NEC Article 200 Series32
- 22.1210.19 Conductors – Minimum Ampacity and Size
- 22.2210.19 Conductors – Minimum Ampacity and Size1 Question
- 22.3210.23 Permissible Loads, Multiple-Outlet Branch Circuits
- 22.4210.23 Permissible Loads, Multiple-Outlet Branch Circuits1 Question
- 22.5210.70 Lighting Outlets Required
- 22.6210.70 Lighting Outlets Required1 Question
- 22.7220.110 Receptacle Loads
- 22.8220.110 Receptacle Loads1 Question
- 22.9220.120 Marinas, Boatyards, Floating Buildings, And Commercial and Noncommercial Docking Facilities
- 22.10220.120 Marinas, Boatyards, Floating Buildings, And Commercial and Noncommercial Docking Facilities1 Question
- 22.11220.57 Electric Vehicle Supply Equipment
- 22.12220.57 Electric Vehicle Supply Equipment1 Question
- 22.13220.70 Energy Management Systems (EMSs)
- 22.14220.70 Energy Management Systems (EMSs)1 Question
- 22.15215.15 Barriers
- 22.16215.15 Barriers1 Question
- 22.17210.52(C) Island and Peninsular Countertops and Work Surfaces
- 22.18210.52(C) Island and Peninsular Countertops and Work Surfaces1 Question
- 22.19220.5(C) Floor Areas
- 22.20220.5(C) Floor Areas1 Question
- 22.21230.71(B) Two to Six Disconnecting Means
- 22.22230.71(B) Two to Six Disconnecting Means1 Question
- 22.23240.11 Selective Coordination
- 22.24240.11 Selective Coordination1 Question
- 22.25240.4(B) Overcurrent Devices Rated 8000 Amperes or Less
- 22.26240.4(B) Overcurrent Devices Rated 8000 Amperes or Less1 Question
- 22.27240.4(D)(3) 14 AWG Copper-Clad Aluminum
- 22.28240.4(D)(3) 14 AWG Copper-Clad Aluminum1 Question
- 22.29Table 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers
- 22.30Table 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers1 Question
- 22.31Table 240.6(D) Remotely Accessible Adjustable-Trip Circuit Breakers
- 22.32Table 240.6(D) Remotely Accessible Adjustable-Trip Circuit Breakers1 Question
- NEC 2023 - Theory and Calculations - NEC Article 300 Series6
- NEC 2023 - Theory and Calculations - NEC Article 400 Series10
- 24.1404.14 Rating and Use of Switches
- 24.2404.14 Rating and Use of Switches1 Question
- 24.3406.3 Receptacle Rating and Type
- 24.4406.3 Receptacle Rating and Type1 Question
- 24.5422.18 Ceiling-Suspended (Paddle) Fans
- 24.6422.18 Ceiling-Suspended (Paddle) Fans1 Question
- 24.7430.6 Conductor Ampacity and Motor Rating Determination
- 24.8430.6 Conductor Ampacity and Motor Rating Determination1 Question
- 24.9440.8 Single Machine and Location
- 24.10440.8 Single Machine and Location1 Question
- NEC 2023 - Theory and Calculations - NEC Article 600 Series4
- NEC 2023 - Theory and Calculations - NEC Article 700 Series10
- 26.1700.4 Capacity and Rating
- 26.2700.4 Capacity and Rating1 Question
- 26.3705.12(A) Feeders and Feeder Taps
- 26.4705.12(A) Feeders and Feeder Taps1 Question
- 26.5726.144 Ampacity
- 26.6726.144 Ampacity1 Question
- 26.7700.12(C) Supply Duration
- 26.8700.12(C) Supply Duration1 Question
- 26.9750.30(C) Capacity of Branch Circuit, Feeder, or Service
- 26.10750.30(C) Capacity of Branch Circuit, Feeder, or Service1 Question
- NFPA 70E 2024 Course Content100
- 27.1Understanding the Purpose and Scope of NFPA 70E 2024 (Article 90)
- 27.2Quiz – Understanding the Purpose and Scope of NFPA 70E 2024 (Article 90)1 Question
- 27.3Key Definitions for Electrical Safety (Article 100)
- 27.4Quiz – Key Definitions for Electrical Safety (Article 100)1 Question
- 27.5Employer and Employee Responsibilities (Article 105)
- 27.6Quiz – Employer and Employee Responsibilities (Article 105)1 Question
- 27.7Core Elements of the Electrical Safety Program (ESP) [Section 110.2 & Section 110.3]
- 27.8Quiz – Core Elements of the Electrical Safety Program (ESP)1 Question
- 27.9Job Safety Planning and Job Briefings [Subdivision 110.3(I)]
- 27.10Quiz – Job Safety Planning and Job Briefings1 Question
- 27.11Training Requirements for Qualified and Unqualified Persons [Subdivision 110.4(A)]
- 27.12Quiz – Training Requirements for Qualified and Unqualified Persons1 Question
- 27.13Safe Selection and Use of Test Instruments [Section 110.6]
- 27.14Quiz – Safe Selection and Use of Test Instruments1 Question
- 27.15The Priority of an Electrically Safe Work Condition [Subdivision 110.2(B)]
- 27.16Quiz – The Priority of an Electrically Safe Work Condition1 Question
- 27.17Principles of a Lockout/Tagout (LOTO) Program [Section 120.3]
- 27.18Quiz – Principles of a Lockout/Tagout (LOTO) Program1 Question
- 27.19Simple vs. Complex Lockout/Tagout Procedures [Section 120.5]
- 27.20Quiz – Simple vs. Complex Lockout/Tagout Procedures1 Question
- 27.21The Step-by-Step De-energization Process [Section 120.6]
- 27.22Quiz – The Step-by-Step De-energization Process1 Question
- 27.23Verifying the Absence of Voltage [Subdivision 120.6(7)]
- 27.24Quiz – Verifying the Absence of Voltage1 Question
- 27.25Justifying Energized Work and the Energized Electrical Work Permit (EEWP)
- 27.26Quiz – Justifying Energized Work and the Energized Electrical Work Permit (EEWP)1 Question
- 27.27Performing an Electric Shock Risk Assessment [Section 130.4]
- 27.28Quiz – Performing a Shock Risk Assessment1 Question
- 27.29Limited and Restricted Approach Boundaries [Subdivision 130.4(E)]
- 27.30Quiz – Limited and Restricted Approach Boundaries1 Question
- 27.31Performing an Arc Flash Risk Assessment [Section 130.5]
- 27.32Quiz – Performing an Arc Flash Risk Assessment1 Question
- 27.33Determining the Arc Flash Boundary [Section 130.7]
- 27.34Quiz – Determining the Arc Flash Boundary1 Question
- 27.35Methods for Selecting Arc Flash PPE [Subdivision 130.5(F)]
- 27.36Quiz – Methods for Selecting Arc Flash PPE1 Question
- 27.37Understanding Arc Flash PPE Categories [Table 130.7(C)(15)(c)]
- 27.38Quiz – Understanding Arc Flash PPE Categories1 Question
- 27.39Requirements for Arc-Rated Clothing and Underlayers [Subdivision 130.7(C)(9)(c)]
- 27.40Quiz – Requirements for Arc-Rated Clothing and Underlayers1 Question
- 27.41Head, Face, Hand, and Foot Protection [Table 130.7(C)(15)(c)]
- 27.42Quiz – Head, Face, Hand, and Foot Protection1 Question
- 27.43General Requirements for Safety-Related Maintenance [Article 205]
- 27.44Quiz – General Requirements for Safety-Related Maintenance1 Question
- 27.45Maintenance of Switchgear, Panelboards, and MCCs [Article 210]
- 27.46Quiz – Maintenance of Switchgear, Panelboards, and MCCs1 Question
- 27.47Maintenance of Fuses and Circuit Breakers [Article 225]
- 27.48Quiz – Maintenance of Fuses and Circuit Breakers1 Question
- 27.49Safety Practices for Batteries and Battery Rooms [Article 320]
- 27.50Quiz – Safety Practices for Batteries and Battery Rooms1 Question
- 27.51Overview of the NFPA 70E Informative Annexes
- 27.52Quiz – Overview of the NFPA 70E Informative Annexes1 Question
- 27.53Defining and Using the Arc Flash Boundary (Subdevision130.5(E))
- 27.54Quiz – Defining and Using the Arc Flash Boundary (Subdivision 130.5(E))1 Question
- 27.55PPE Selection: Incident Energy Analysis Method (Subdivision130.5(G))
- 27.56Quiz – PPE Selection: Incident Energy Analysis Method (Subdivision130.5(G))1 Question
- 27.57PPE Selection: Arc Flash PPE Category Method (Subdivision130.7(C)(15))
- 27.58Quiz – PPE Selection: Arc Flash PPE Category Method (Subdivision 130.7(C)(15))1 Question
- 27.59Using the PPE Category Tables for AC Systems (Table 130.7(C)(15)(a))
- 27.60Quiz – Using the PPE Category Tables for AC Systems (Table 130.7(C)(15)(a))1 Question
- 27.61Using the PPE Category Tables for DC Systems (Table 130.7(C)(15)(b))
- 27.62Quiz – Using the PPE Category Tables for DC Systems (Table 130.7(C)(15)(b))1 Question
- 27.63Requirements for Arc-Rated and Underlayer Clothing (Subdivision 130.7(C))
- 27.64Quiz – Requirements for Arc-Rated Clothing and Underlayers1 Question
- 27.65Personal Protective Equipment: Head, Face, Hand, and Foot Protection (Section 130.7)
- 27.66Quiz – Personal Protective Equipment: Head, Face, Hand, and Foot Protection (Section 130.7)1 Question
- 27.67Care, Inspection, and Maintenance of PPE (Subdivision 130.7(B))
- 27.68Quiz – Care, Inspection, and Maintenance of PPE (Subdivision 130.7(B))1 Question
- 27.69Barricades, Attendants, and Alerting Techniques (Subdivision 130.8(O))
- 27.70Quiz – Barricades, Attendants, and Alerting Techniques (Subdivision 130.8(O))1 Question
- 27.71The Importance of Safety-Related Maintenance (Article 200, 205)
- 27.72Quiz – The Importance of Safety-Related Maintenance (Article 200, 205)1 Question
- 27.73Maintenance of Switchgear, Panelboards, and Motor Control Centers (Article 210)
- 27.74Quiz – Maintenance of Switchgear, Panelboards, and Motor Control Centers (Article 210)1 Question
- 27.75Maintenance of Fuses and Circuit Breakers (Article 225)
- 27.76Quiz – Maintenance of Fuses and Circuit Breakers (Article 225)1 Question
- 27.77Maintenance of Rotating Equipment and Controller Equipment (Article 220,230)
- 27.78Quiz – Maintenance of Rotating Equipment and Controller Equipment (Article 220,230)1 Question
- 27.79General Safety Requirements for Special Equipment (Article 300)
- 27.80Quiz – General Safety Requirements for Special Equipment (Article 300)1 Question
- 27.81Safety Practices for Batteries and Battery Rooms (Article 320)
- 27.82Quiz – Safety Practices for Batteries and Battery Rooms (Article 320)1 Question
- 27.83Safety Practices for Lasers (Article 330)
- 27.84Quiz – Safety Practices for Lasers (Article 330)1 Question
- 27.85Safety Practices for Power Electronic Equipment (Article 340)
- 27.86Quiz – Safety Practices for Power Electronic Equipment (Article 340)1 Question
- 27.87Safety Requirements for Research and Development Labs (Article 350)
- 27.88Quiz – Safety Requirements for Research and Development Labs (Article 350)1 Question
- 27.89Safety Requirements for Capacitors (Article 360)
- 27.90Quiz – Safety Requirements for Capacitors (Article 360)1 Question
- 27.91Applying Informative Annex F: Risk Assessment and Risk Control
- 27.92Quiz – Applying Informative Annex F: Risk Assessment and Risk Control1 Question
- 27.93Applying Informative Annex H: Guidance on PPE Selection
- 27.94Quiz – Applying Informative Annex H: Guidance on PPE Selection1 Question
- 27.95Applying Informative Annex I: Job Briefing and Planning Checklist
- 27.96Quiz – Applying Informative Annex I: Job Briefing and Planning Checklist1 Question
- 27.97Applying Informative Annex J: Energized Electrical Work Permit Example
- 27.98Quiz – Applying Informative Annex J: Energized Electrical Work Permit Example1 Question
- 27.99Core Elements of the Electrical Safety Program (ESP) [Section 110.2 & Section 110.3]
- 27.100Quiz – Real-World Application Scenarios1 Question
