This 8-hour online course for Michigan Sign Specialists provides a comprehensive review of the most significant changes in the 2023 National Electrical Code (NEC). It also includes the mandatory Michigan 2023 NEC Amendments from the Michigan Electrical Code Rules Part 8, which are required for license renewal.
Course Features
- Lectures 75
- Quizzes 75
- Duration 52 weeks
- Skill level All levels
- Language English
- Students 0
- Certificate Yes
- Assessments Yes
- 7 Sections
- 75 Lessons
- 52 Weeks
- NEC Courses Article 100 Series30
- 1.1100 – Definitions
- 1.2100 – Definitions1 Question
- 1.3110.17 – Servicing and Maintenance of Equipment
- 1.4110.17 – Servicing and Maintenance of Equipment1 Question
- 1.5110.20 – Reconditioned Equipment
- 1.6110.20 – Reconditioned Equipment1 Question
- 1.7110.21 – Markings
- 1.8110.21 – Markings1 Question
- 1.9110.26 – Spaces About Electrical Equipment
- 1.10110.26 – Spaces About Electrical Equipment1 Question
- 1.11110.29 – In Sight From
- 1.12110.29 In Sight From1 Question
- 1.13110.3 – Examination, Identification, Installation, Use, and Listing (Product Certification) of Equipment.
- 1.14110.3 – Examination, Identification, Installation, Use, and Listing (Product Certification) of Equipment.1 Question
- 1.15110.14(A) – Electrical Connections – Terminals
- 1.16110.14(A) – Electrical Connections – Terminals1 Question
- 1.17110.16(B) – Arc-Flash Hazard Warnings – Service Equipment
- 1.18110.16(B) – Arc-Flash Hazard Warnings – Service Equipment1 Question
- 1.19110.2(B) When Required
- 1.20110.2(B) When Required1 Question
- 1.21110.22(A) – Identification of Disconnecting Means
- 1.22110.22(A) – Identification of Disconnecting Means1 Question
- 1.23110.3(I) Job Safety Planning and Job Briefing
- 1.24110.3(I) Job Safety Planning and Job Briefing1 Question
- 1.25110.33(A) and 110.34(A)
- 1.26110.33(A) and 110.34(A)1 Question
- 1.27110.33(A) and 110.34(A)
- 1.28110.33(A) and 110.34(A)1 Question
- 1.29120.6 Process for Establishing and Verifying an Electrically Safe Work Condition
- 1.30120.6 Process for Establishing and Verifying an Electrically Safe Work Condition1 Question
- NEC Courses Article 200 Series38
- 2.1210.19 Conductors – Minimum Ampacity and Size
- 2.2210.19 Conductors – Minimum Ampacity and Size1 Question
- 2.3210.23 Permissible Loads, Multiple-Outlet Branch Circuits
- 2.4210.23 Permissible Loads, Multiple-Outlet Branch Circuits1 Question
- 2.5210.70 Lighting Outlets Required
- 2.6210.70 Lighting Outlets Required1 Question
- 2.7215.18 Surge Protection
- 2.8215.18 Surge Protection1 Question
- 2.9230.67 Surge ProtectionÂ
- 2.10230.67 Surge Protection1 Question
- 2.11240.11 Selective Coordination
- 2.12240.11 Selective Coordination1 Question
- 2.13240.2 Reconditioned Equipment
- 2.14240.2 Reconditioned Equipment1 Question
- 2.15250.130 – Equipment Grounding Conductor Connections
- 2.16250.130 – Equipment Grounding Conductor Connections1 Question
- 2.17250.140 – Frames of Ranges and Clothes Dryers
- 2.18250.140 – Frames of Ranges and Clothes Dryers1 Question
- 2.19250.148 – Continuity of Equipment Grounding Conductors and Attachment in Boxes
- 2.20250.148 – Continuity of Equipment Grounding Conductors and Attachment in Boxes1 Question
- 2.21250.70 – Grounding and Bonding Conductor Connection to Electrodes
- 2.22250.70 – Grounding and Bonding Conductor Connection to Electrodes1 Question
- 2.23210.8(F) Outdoor Outlets.
- 2.24210.8(F) Outdoor Outlets.1 Question
- 2.25220.5(C) Floor Areas
- 2.26220.5(C) Floor Areas1 Question
- 2.27240.24(A) and (E) – Location in or on Premises
- 2.28240.24(A) and (E) – Location in or on Premises1 Question
- 2.29240.4(B) Overcurrent Devices Rated 8000 Amperes or LessÂ
- 2.30240.4(B) Overcurrent Devices Rated 8000 Amperes or Less1 Question
- 2.31Table 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit BreakersÂ
- 2.32Table 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers1 Question
- 2.33242.2 and 242.9 – Surge Protective Devices
- 2.34242.2 and 242.9 – Surge Protective Devices1 Question
- 2.35250.24(D) – Grounded Conductor Brought to Service Equipment
- 2.36250.24(D) – Grounded Conductor Brought to Service Equipment1 Question
- 2.37250.64(G) – Enclosures with Ventilation Openings
- 2.38250.64(G) – Enclosures with Ventilation Openings1 Question
- NEC Courses Article 300 Series32
- 3.1300.14 Length of Free Conductors at Outlets, Junctions, and Switch Points
- 3.2300.14 Length of Free Conductors at Outlets, Junctions, and Switch Points1 Question
- 3.3312.10 Screws or Other Fasteners
- 3.4312.10 Screws or Other Fasteners1 Question
- 3.5314.16 Box Fill Calculations
- 3.6314.16 Box Fill Calculations1 Question
- 3.7314.24 Dimensions of Boxes
- 3.8314.24 Dimensions of Boxes1 Question
- 3.9314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible
- 3.10314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible1 Question
- 3.11314.5 Screws or Other Fasteners
- 3.12314.5 Screws or Other Fasteners1 Question
- 3.13320.23 In Accessible Attics
- 3.14320.23 In Accessible Attics1 Question
- 3.15334.10 Uses Permitted
- 3.16334.10 Uses Permitted1 Question
- 3.17334.15 (B) Protection from Physical Damage
- 3.18334.15 (B) Protection from Physical Damage1 Question
- 3.19342.20 Size
- 3.20342.20 Size1 Question
- 3.21352.10 Uses Permitted for Rigid Polyvinyl Chloride Conduits
- 3.22352.10 Uses Permitted for Rigid Polyvinyl Chloride Conduits1 Question
- 3.23352.44 Expansion Fittings
- 3.24352.44 Expansion Fittings1 Question
- 3.25356.10 Uses Permitted
- 3.26356.10 Uses Permitted1 Question
- 3.27398.15 Exposed Work
- 3.28398.15 Exposed Work1 Question
- 3.29300.11(C) Raceways Used as Means of Support
- 3.30300.11(C) Raceways Used as Means of Support1 Question
- 3.31300.3 (C) Conductors of Different Systems
- 3.32300.3 (C) Conductors of Different Systems1 Question
- NEC Courses Article 400 Series16
- 4.1404.14 Rating and Use of SwitchesÂ
- 4.2404.14 Rating and Use of Switches1 Question
- 4.3404.30 Switch Enclosures with Doors
- 4.4404.30 Switch Enclosures with Doors1 Question
- 4.5406.12 Tamper-Resistant Receptacles.
- 4.6406.12 Tamper-Resistant Receptacles.1 Question
- 4.7406.3 Receptacle Rating and Type
- 4.8406.3 Receptacle Rating and Type1 Question
- 4.9408.38 Enclosure
- 4.10408.38 Enclosure1 Question
- 4.11408.4 Descriptions Required
- 4.12408.4 Descriptions Required1 Question
- 4.13409.70 Surge Protection
- 4.14409.70 Surge Protection1 Question
- 4.15410.10 Luminaires in Specific Locations
- 4.16410.10 Luminaires in Specific Locations1 Question
- NEC Courses Article 500 Series14
- 5.1501.30 Grounding and Bonding
- 5.2501.30 Grounding and Bonding1 Question
- 5.3511.7(A) Wiring in Spaces Above Hazardous (Classified) Locations
- 5.4511.7(A) Wiring in Spaces Above Hazardous (Classified) Locations1 Question
- 5.5517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care Spaces
- 5.6517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care Spaces1 Question
- 5.7517.14 Panelboard Bonding
- 5.8517.14 Panelboard Bonding1 Question
- 5.9518.4 Wiring Methods
- 5.10518.4 Wiring Methods1 Question
- 5.11555.14 Equipotential Planes and Bonding of Equipotential Planes
- 5.12555.14 Equipotential Planes and Bonding of Equipotential Planes1 Question
- 5.13500.5 (D) Classifications of Locations
- 5.14500.5 (D) Classifications of Locations1 Question
- NEC Courses Article 600 Series10
- 6.1600.35 – Retrofit Kits
- 6.2600.35 – Retrofit Kits1 Question
- 6.3600.6 – Disconnects
- 6.4600.6 – Disconnects1 Question
- 6.5620.36 – Different Systems in One Raceway or Traveling Cable.
- 6.6620.36 – Different Systems in One Raceway or Traveling Cable.1 Question
- 6.7620.6 – GFCI Protection for Personnel
- 6.8620.6 – GFCI Protection for Personnel1 Question
- 6.9625.40 Electric Vehicle Branch Circuit
- 6.10625.40 Electric Vehicle Branch Circuit1 Question
- NFPA NEC Chapters10
- 7.1110.2(B) When Required
- 7.2110.2(B) When Required1 Question
- 7.3110.3(I) Job Safety Planning and Job Briefing
- 7.4110.3(I) Job Safety Planning and Job Briefing1 Question
- 7.5120.6 Process for Establishing and Verifying an Electrically Safe Work Condition
- 7.6120.6 Process for Establishing and Verifying an Electrically Safe Work Condition1 Question
- 7.7130.7(C)(5) Hearing Protection
- 7.8130.7(C)(5) Hearing Protection1 Question
- 7.9320.3(A)(1) Electrical Hazard Thresholds.
- 7.10320.3(A)(1) Electrical Hazard Thresholds.10 Minutes1 Question






