Status: ✅ Board Approved by the Delaware Board of Electrical Examiners Format: Online, Self-Paced (Mobile Friendly)
Course Overview Get your complete Delaware continuing education requirement done in one convenient package. This 10-hour Board-Approved course offers a thorough review of the National Electrical Code (NEC), taking you from the fundamentals of safety and wiring all the way to advanced specialized systems.
We have structured this course to be practical and job-focused. You will review essential updates to Articles 100–300, explore equipment standards in Article 400, and tackle complex installations like hazardous locations, EV chargers, and emergency systems in Articles 500–800.
What You Will Learn This comprehensive curriculum is divided into 3 core subject areaa covering the full spectrum of the NEC:
Subject area 1: Safety & General Wiring (Articles 100–300)
-
Safety First: Review critical definitions, Arc-Flash Hazard warnings (110.16), and NFPA 70E safety protocols including PPE and job briefings.
-
Wiring & Protection: Master branch circuit loads, new Surge Protection requirements (230.67), and emergency disconnects.
-
Methods & Materials: Refine your skills with Box Fill Calculations (314.16), conductor sizing, and proper use of medium voltage cables.
Subject area 2: Equipment & Motors (Article 400)
-
Everyday Equipment: Updated rules for switches, tamper-resistant receptacles, and replacement panelboards.
-
Appliances & Fixtures: Installation standards for luminaires, ceiling fans, and electric radiant heating panels.
-
Motors: Conductor ampacity, motor ratings (430.6), and emergency shutdown procedures for prime movers.
Subject 3: Special Occupancies & Systems (Articles 500–800)
-
Hazardous & Healthcare: Grounding/bonding in Class I/II locations and critical power requirements for patient care spaces (517.13).
-
Modern Tech: Deep dive into Electric Vehicle (EV) branch circuits, “Island Mode” charging, and renewable energy interconnections.
-
Emergency Systems: Wiring for emergency lighting, outdoor generator sets, and legally required standby systems.
-
Communications: Proper installation of low-voltage cabling and plenum cable ties.
Why Choose ExpertCE?
-
All-in-One Solution: Covers a massive 10 hours of credit in a single, cohesive course.
-
100% Board Approved: Fully compliant with Delaware license renewal standards.
-
Instant Certificate: Download your official certificate immediately upon completion.
-
Save Your Progress: Start on your laptop, finish on your phone. Our platform remembers exactly where you left off.
Course Features
- Lectures 100
- Quizzes 100
- Duration 52 weeks
- Skill level All levels
- Language English
- Students 0
- Certificate Yes
- Assessments Self
- 9 Sections
- 100 Lessons
- 52 Weeks
- NEC Courses Article 100 Series32
- 1.1100 – Definitions
- 1.2100 – Definitions1 Question
- 1.3110.17 – Servicing and Maintenance of Equipment
- 1.4110.17 – Servicing and Maintenance of Equipment1 Question
- 1.5110.20 – Reconditioned Equipment
- 1.6110.20 – Reconditioned Equipment1 Question
- 1.7110.21 – Markings
- 1.8110.21 – Markings1 Question
- 1.9110.26 – Spaces About Electrical Equipment
- 1.10110.26 – Spaces About Electrical Equipment1 Question
- 1.11110.29 – In Sight From
- 1.12110.29 In Sight From1 Question
- 1.13110.3 – Examination, Identification, Installation, Use, and Listing (Product Certification) of Equipment.
- 1.14110.3 – Examination, Identification, Installation, Use, and Listing (Product Certification) of Equipment.1 Question
- 1.15110.14(A) – Electrical Connections – Terminals
- 1.16110.14(A) – Electrical Connections – Terminals1 Question
- 1.17110.16(B) – Arc-Flash Hazard Warnings – Service Equipment
- 1.18110.16(B) – Arc-Flash Hazard Warnings – Service Equipment1 Question
- 1.19110.2(B) When Required
- 1.20110.2(B) When Required1 Question
- 1.21110.22(A) – Identification of Disconnecting Means
- 1.22110.22(A) – Identification of Disconnecting Means1 Question
- 1.23110.3(I) Job Safety Planning and Job Briefing
- 1.24110.3(I) Job Safety Planning and Job Briefing1 Question
- 1.25110.33(A) and 110.34(A)
- 1.26110.33(A) and 110.34(A)1 Question
- 1.27110.33(A) and 110.34(A)
- 1.28110.33(A) and 110.34(A)1 Question
- 1.29120.6 Process for Establishing and Verifying an Electrically Safe Work Condition
- 1.30120.6 Process for Establishing and Verifying an Electrically Safe Work Condition1 Question
- 1.31130.7(C)(5) Hearing Protection
- 1.32130.7(C)(5) Hearing Protection1 Question
- NEC Courses Article 200 Series32
- 2.1210.17 Guest Rooms and Guest Suites
- 2.2210.17 Guest Rooms and Guest Suites1 Question
- 2.3210.19 Conductors – Minimum Ampacity and Size
- 2.4210.19 Conductors – Minimum Ampacity and Size1 Question
- 2.5210.23 Permissible Loads, Multiple-Outlet Branch Circuits
- 2.6210.23 Permissible Loads, Multiple-Outlet Branch Circuits1 Question
- 2.7210.70 Lighting Outlets Required
- 2.8210.70 Lighting Outlets Required1 Question
- 2.9215.15 Barriers
- 2.10215.15 Barriers1 Question
- 2.11215.18 Surge Protection
- 2.12215.18 Surge Protection1 Question
- 2.13220.1 Scope
- 2.14220.1 Scope1 Question
- 2.15220.110 Receptacle Loads
- 2.16220.110 Receptacle Loads1 Question
- 2.17220.120 Marinas, Boatyards, Floating Buildings, And Commercial and Noncommercial Docking Facilities
- 2.18220.120 Marinas, Boatyards, Floating Buildings, And Commercial and Noncommercial Docking Facilities1 Question
- 2.19220.57 Electric Vehicle Supply Equipment
- 2.20220.57 Electric Vehicle Supply Equipment1 Question
- 2.21220.70 Energy Management Systems (EMSs)
- 2.22220.70 Energy Management Systems (EMSs)1 Question
- 2.23225.41 Emergency Disconnects
- 2.24225.41 Emergency Disconnects1 Question
- 2.25230.67 Surge Protection
- 2.26230.67 Surge Protection1 Question
- 2.27230.85 Emergency Disconnects
- 2.28230.85 Emergency Disconnects1 Question
- 2.29Article 235 – Branch Circuits, Feeders and Services over 1000 Volts AC, 1500 Volts DC, Nominal
- 2.30Article 235 – Branch Circuits, Feeders and Services over 1000 Volts AC, 1500 Volts DC, Nominal1 Question
- 2.31240.11 Selective Coordination
- 2.32240.11 Selective Coordination1 Question
- NEC Courses Article 300 Series20
- 3.1300.14 Length of Free Conductors at Outlets, Junctions, and Switch Points
- 3.2300.14 Length of Free Conductors at Outlets, Junctions, and Switch Points1 Question
- 3.3312.10 Screws or Other Fasteners
- 3.4312.10 Screws or Other Fasteners1 Question
- 3.5314.16 Box Fill Calculations
- 3.6314.16 Box Fill Calculations1 Question
- 3.7314.24 Dimensions of Boxes
- 3.8314.24 Dimensions of Boxes1 Question
- 3.9314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible
- 3.10314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible1 Question
- 3.11314.5 Screws or Other Fasteners
- 3.12314.5 Screws or Other Fasteners1 Question
- 3.13315.17 Marking for Type Medium Voltage Cable Joints, and Terminations
- 3.14315.17 Marking for Type Medium Voltage Cable Joints, and Terminations1 Question
- 3.15315.32 Uses Permitted for Type Medium Voltage Cables, Cable Joints, and Terminations
- 3.16315.32 Uses Permitted for Type Medium Voltage Cables, Cable Joints, and Terminations1 Question
- 3.17320.23 In Accessible Attics
- 3.18320.23 In Accessible Attics1 Question
- 3.19334.10 Uses Permitted
- 3.20334.10 Uses Permitted1 Question
- NEC Courses Article 400 Series16
- 4.1404.14 Rating and Use of Switches
- 4.2404.14 Rating and Use of Switches1 Question
- 4.3404.16 Reconditioned Equipment
- 4.4404.16 Reconditioned Equipment1 Question
- 4.5404.30 Switch Enclosures with Doors
- 4.6404.30 Switch Enclosures with Doors1 Question
- 4.7406.12 Tamper-Resistant Receptacles.
- 4.8406.12 Tamper-Resistant Receptacles.1 Question
- 4.9406.3 Receptacle Rating and Type
- 4.10406.3 Receptacle Rating and Type1 Question
- 4.11408.38 Enclosure
- 4.12408.38 Enclosure1 Question
- 4.13408.4 Descriptions Required
- 4.14408.4 Descriptions Required1 Question
- 4.15408.9 Replacement Panelboards
- 4.16408.9 Replacement Panelboards1 Question
- NEC Courses Article 400 Series32
- 5.1410.10 Luminaires in Specific Locations
- 5.2410.10 Luminaires in Specific Locations1 Question
- 5.3410.184 Ground-Fault Circuit-Interrupter (GFCI) Protection and Special Purpose Ground-Fault Circuit-Interrupter (SPGFCI) Protection
- 5.4410.184 Ground-Fault Circuit-Interrupter (GFCI) Protection and Special Purpose Ground-Fault Circuit-Interrupter (SPGFCI) Protection1 Question
- 5.5410.195 Locations Not Permitted
- 5.6410.195 Locations Not Permitted1 Question
- 5.7410.197 Germicidal Irradiation Systems
- 5.8410.197 Germicidal Irradiation Systems1 Question
- 5.9410.71(1) General
- 5.10410.71(1) General1 Question
- 5.11422.18 Ceiling-Suspended (Paddle) Fans
- 5.12422.18 Ceiling-Suspended (Paddle) Fans1 Question
- 5.13424.48 Installation of Cables in Walls
- 5.14424.48 Installation of Cables in Walls1 Question
- 5.15424.93 Installation of Electric Radiant Heating Panels and Heating Panel Sets
- 5.16424.93 Installation of Electric Radiant Heating Panels and Heating Panel Sets1 Question
- 5.17430.2 Reconditioned Motors
- 5.18430.2 Reconditioned Motors1 Question
- 5.19430.6 Conductor Ampacity and Motor Rating Determination
- 5.20430.6 Conductor Ampacity and Motor Rating Determination1 Question
- 5.21440.8 Single Machine and Location
- 5.22440.8 Single Machine and Location1 Question
- 5.23445.19 Emergency Shutdown of Prime Mover
- 5.24445.19 Emergency Shutdown of Prime Mover1 Question
- 5.25470.2 Reconditioned Equipment
- 5.26470.2 Reconditioned Equipment1 Question
- 5.27406.4(D) Receptacle Replacements
- 5.28406.4(D) Receptacle Replacements1 Question
- 5.29406.6(D) Receptacle Faceplate (Cover Plates) With Integral Night Light and/or USB Charger
- 5.30406.6(D) Receptacle Faceplate (Cover Plates) With Integral Night Light and/or USB Charger1 Question
- 5.31406.9 (C) Bathtub and Shower Space
- 5.32406.9 (C) Bathtub and Shower Space1 Question
- NEC Courses Article 500 Series20
- 6.1501.30 Grounding and Bonding
- 6.2501.30 Grounding and Bonding1 Question
- 6.3502.30 Grounding and Bonding
- 6.4502.30 Grounding and Bonding1 Question
- 6.5511.7(A) Wiring in Spaces Above Hazardous (Classified) Locations
- 6.6511.7(A) Wiring in Spaces Above Hazardous (Classified) Locations1 Question
- 6.7512.13 Wiring Installed Above Hazardous (Classified) Locations
- 6.8512.13 Wiring Installed Above Hazardous (Classified) Locations1 Question
- 6.9512.20 Equipment and Systems
- 6.10512.20 Equipment and Systems1 Question
- 6.11517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care Spaces
- 6.12517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care Spaces1 Question
- 6.13517.14 Panelboard Bonding
- 6.14517.14 Panelboard Bonding1 Question
- 6.15517.30(B) Power Sources for the EES
- 6.16517.30(B) Power Sources for the EES1 Question
- 6.17518.4 Wiring Methods
- 6.18518.4 Wiring Methods1 Question
- 6.19518.5 Supply
- 6.20518.5 Supply1 Question
- NEC Courses Article 600 Series20
- 7.1600.35 – Retrofit Kits
- 7.2600.35 – Retrofit Kits1 Question
- 7.3600.6 – Disconnects
- 7.4600.6 – Disconnects1 Question
- 7.5620.36 – Different Systems in One Raceway or Traveling Cable.
- 7.6620.36 – Different Systems in One Raceway or Traveling Cable.1 Question
- 7.7620.6 – GFCI Protection for Personnel
- 7.8620.6 – GFCI Protection for Personnel1 Question
- 7.9625.40 Electric Vehicle Branch Circuit
- 7.10625.40 Electric Vehicle Branch Circuit1 Question
- 7.11625.42 Rating
- 7.12625.42 Rating1 Question
- 7.13625.49 – Island Mode
- 7.14625.49 – Island Mode1 Question
- 7.15625.6 – Listed
- 7.16625.6 – Listed1 Question
- 7.17630.8 – Electric Welders
- 7.18630.8 – Electric Welders1 Question
- 7.19646.19 – Entrance to and Egress from Working Space
- 7.20646.19 – Entrance to and Egress from Working Space1 Question
- NEC Courses Article 700 Series20
- 8.1700.11 Wiring, Class-2-Powered Emergency Lighting Systems
- 8.2700.11 Wiring, Class-2-Powered Emergency Lighting Systems1 Question
- 8.3700.27 Class 2 Powered Emergency Lighting Systems
- 8.4700.27 Class 2 Powered Emergency Lighting Systems1 Question
- 8.5700.32 Selective Coordination
- 8.6700.32 Selective Coordination1 Question
- 8.7700.4 Capacity and Rating
- 8.8700.4 Capacity and Rating1 Question
- 8.9701.10 Wiring Legally Required Standby Systems
- 8.10701.10 Wiring Legally Required Standby Systems1 Question
- 8.11702.12 Outdoor Generator Sets
- 8.12702.12 Outdoor Generator Sets1 Question
- 8.13702.5 Interconnection or Transfer Equipment
- 8.14702.5 Interconnection or Transfer Equipment1 Question
- 8.15705.10 Identification of Power Sources
- 8.16705.10 Identification of Power Sources1 Question
- 8.17705.30 Overcurrent Protection
- 8.18705.30 Overcurrent Protection1 Question
- 8.19705.50 System Operation
- 8.20705.50 System Operation1 Question
- NEC Courses Article 800 Series8
- 9.1800.133 – Installation of Wires, Cables, Cable Routing Assemblies, and Communications Raceways
- 9.2800.133 – Installation of Wires, Cables, Cable Routing Assemblies, and Communications Raceways1 Question
- 9.3800.170 – Plenum Cable Ties
- 9.4800.170 – Plenum Cable Ties1 Question
- 9.5800.179 – Wires and Cables
- 9.6800.179 – Wires and Cables1 Question
- 9.7800.24 – Mechanical Execution of Work
- 9.8800.24 – Mechanical Execution of Work1 Question





