This extensive 12-hour continuing education course provides a complete walkthrough of the most significant changes and safety updates in the 2023 National Electrical Code (NEC). We begin by navigating the major structural shift that consolidated all definitions into Article 100, streamlining how you reference the code. The course establishes a strong foundation in General Requirements (Article 110), focusing on critical worker safety protocols such as mandatory Job Safety Planning, new arc-flash hazard warnings for service equipment, and strict labeling standards for reconditioned equipment. You will also learn the updated processes for establishing an electrically safe work condition and complying with new hearing protection thresholds.
Core Installation: Wiring, Protection, and Methods
A significant portion of the training is dedicated to the practical “daily driver” updates in Chapters 2 and 3. We dive deep into the expanded mandates for GFCI protection in commercial kitchens and outdoor outlets, as well as the crucial new requirement for Surge Protection Devices (SPDs) at all dwelling unit services. You will master the installation rules for Emergency Disconnects at one- and two-family dwellings—a major safety change for first responders. The course also introduces you to cutting-edge wiring methods, including the new Article 369 for Insulated Bus Pipe (IBP) and Article 371 for Flexible Bus Systems, alongside updated rules for medium voltage cables and conductor support.
Specialized Applications and Future Technologies
The final segment explores complex environments and emerging technologies found in Chapters 5, 6, and 7. We analyze the brand-new Article 512, which creates specific safety standards for the rapidly growing Cannabis industry, covering oil extraction equipment and cultivation areas. You will review essential updates for Solar PV systems (including floating arrays and rapid shutdown), Electric Vehicle (EV) charging infrastructure, and the strict bonding rules for swimming pools and splash pads. We wrap up by covering the future of power distribution with the introduction of Class 4 Fault-Managed Power Systems (Article 726) and updated rules for emergency lighting and microgrids, ensuring you are prepared for the next generation of electrical work.
Course Features
- Lectures 111
- Quizzes 111
- Duration 52 weeks
- Skill level All levels
- Language English
- Students 2
- Certificate Yes
- Assessments Self
- 8 Sections
- 111 Lessons
- 52 Weeks
- Article 100 Series18
- 1.1100 – Definitions
- 1.2100 – Definitions1 Question
- 1.3110.14(A) – Electrical Connections – Terminals
- 1.4110.14(A) – Electrical Connections – Terminals1 Question
- 1.5110.20 – Reconditioned Equipment
- 1.6110.20 – Reconditioned Equipment1 Question
- 1.7110.21 – Markings
- 1.8110.21 – Markings1 Question
- 1.9110.16(B) – Arc-Flash Hazard Warnings – Service Equipment
- 1.10110.16(B) – Arc-Flash Hazard Warnings – Service Equipment1 Question
- 1.11110.2(B) When Required
- 1.12110.2(B) When Required1 Question
- 1.13110.22(A) – Identification of Disconnecting Means
- 1.14110.22(A) – Identification of Disconnecting Means1 Question
- 1.15120.6 Process for Establishing and Verifying an Electrically Safe Work Condition
- 1.16120.6 Process for Establishing and Verifying an Electrically Safe Work Condition1 Question
- 1.17130.7(C)(5) Hearing Protection
- 1.18130.7(C)(5) Hearing Protection1 Question
- Article 200 Series42
- 2.1210.17 Guest Rooms and Guest Suites
- 2.2210.17 Guest Rooms and Guest Suites1 Question
- 2.3215.18 Surge Protection
- 2.4215.18 Surge Protection1 Question
- 2.5225.41 Emergency Disconnects
- 2.6225.41 Emergency Disconnects1 Question
- 2.7230.67 Surge Protection
- 2.8230.67 Surge Protection1 Question
- 2.9Article 235 – Branch Circuits, Feeders and Services over 1000 Volts AC, 1500 Volts DC, Nominal
- 2.10Article 235 – Branch Circuits, Feeders and Services over 1000 Volts AC, 1500 Volts DC, Nominal1 Question
- 2.11240.2 Reconditioned Equipment
- 2.12240.2 Reconditioned Equipment1 Question
- 2.13Article 245 – Overcurrent Protection over 1000 Volts AC, 1500 Volts DC
- 2.14Article 245 – Overcurrent Protection over 1000 Volts AC, 1500 Volts DC1 Question
- 2.15210.11(C)(4) Garage Branch Circuits
- 2.16210.11(C)(4) Garage Branch Circuits1 Question
- 2.17210.52(G) Basements, Garages, and Accessory Buildings
- 2.18210.52(G) Basements, Garages, and Accessory Buildings1 Question
- 2.19240.24(A) and (E) – Location in or on Premises
- 2.20240.24(A) and (E) – Location in or on Premises1 Question
- 2.21250.130 – Equipment Grounding Conductor Connections
- 2.22250.130 – Equipment Grounding Conductor Connections1 Question
- 2.23250.140 – Frames of Ranges and Clothes Dryers
- 2.24250.140 – Frames of Ranges and Clothes Dryers1 Question
- 2.25250.148 – Continuity of Equipment Grounding Conductors and Attachment in Boxes
- 2.26250.148 – Continuity of Equipment Grounding Conductors and Attachment in Boxes1 Question
- 2.27250.36 – Impedance Grounded Systems
- 2.28250.36 – Impedance Grounded Systems1 Question
- 2.29250.70 – Grounding and Bonding Conductor Connection to Electrodes
- 2.30250.70 – Grounding and Bonding Conductor Connection to Electrodes1 Question
- 2.31210.8(B) Other Than Dwelling Units
- 2.32210.8(B) Other Than Dwelling Units1 Question
- 2.33210.8(F) Outdoor Outlets.
- 2.34210.8(F) Outdoor Outlets.1 Question
- 2.35242.2 and 242.9 – Surge Protective Devices
- 2.36242.2 and 242.9 – Surge Protective Devices1 Question
- 2.37250.24(D) – Grounded Conductor Brought to Service Equipment
- 2.38250.24(D) – Grounded Conductor Brought to Service Equipment1 Question
- 2.39230.85 Emergency Disconnects
- 2.40230.85 Emergency Disconnects1 Question
- 2.41250.64(G) – Enclosures with Ventilation Openings
- 2.42250.64(G) – Enclosures with Ventilation Openings1 Question
- Article 300 Series24
- 3.1315.17 Marking for Type Medium Voltage Cable Joints, and Terminations
- 3.2315.17 Marking for Type Medium Voltage Cable Joints, and Terminations1 Question
- 3.3315.32 Uses Permitted for Type Medium Voltage Cables, Cable Joints, and Terminations
- 3.4315.32 Uses Permitted for Type Medium Voltage Cables, Cable Joints, and Terminations1 Question
- 3.5369.10 Uses Permitted for Insulated Bus Pipe (IBP) Systems
- 3.6369.10 Uses Permitted for Insulated Bus Pipe (IBP) Systems1 Question
- 3.7369.120 Marking Insulated Bus Pipe (IBP) Systems
- 3.8369.120 Marking Insulated Bus Pipe (IBP) Systems1 Question
- 3.9371.17 Overcurrent Protection of Flexible Bus System
- 3.10371.17 Overcurrent Protection of Flexible Bus System1 Question
- 3.11371.30 Securing and Supporting
- 3.12371.30 Securing and Supporting1 Question
- 3.13398.15 Exposed Work
- 3.14398.15 Exposed Work1 Question
- 3.15300.3 (C) Conductors of Different Systems
- 3.16300.3 (C) Conductors of Different Systems1 Question
- 3.17300.11(C) Raceways Used as Means of Support
- 3.18300.11(C) Raceways Used as Means of Support1 Question
- 3.19320.3(A)(1) Electrical Hazard Thresholds.
- 3.20320.3(A)(1) Electrical Hazard Thresholds.10 Minutes1 Question
- 3.21371.10 and 371.12 Uses Permitted and Not Permitted
- 3.22371.10 and 371.12 Uses Permitted and Not Permitted1 Question
- 3.23315.44 & 315.45 Shielding Requirements for Medium Voltage Equipment
- 3.24315.44 & 315.45 Shielding Requirements for Medium Voltage Equipment1 Question
- Article 400 Series28
- 4.1404.16 Reconditioned Equipment
- 4.2404.16 Reconditioned Equipment1 Question
- 4.3406.12 Tamper-Resistant Receptacles.
- 4.4406.12 Tamper-Resistant Receptacles.1 Question
- 4.5408.4 Descriptions Required
- 4.6408.4 Descriptions Required1 Question
- 4.7408.9 Replacement Panelboards
- 4.8408.9 Replacement Panelboards1 Question
- 4.9409.70 Surge Protection
- 4.10409.70 Surge Protection1 Question
- 4.11410.197 Germicidal Irradiation Systems
- 4.12410.197 Germicidal Irradiation Systems1 Question
- 4.13410.71(1) General
- 4.14410.71(1) General1 Question
- 4.15430.2 Reconditioned Motors
- 4.16430.2 Reconditioned Motors1 Question
- 4.17445.19 Emergency Shutdown of Prime Mover
- 4.18445.19 Emergency Shutdown of Prime Mover1 Question
- 4.19470.2 Reconditioned Equipment
- 4.20470.2 Reconditioned Equipment1 Question
- 4.21406.6(D) Receptacle Faceplate (Cover Plates) With Integral Night Light and/or USB Charger
- 4.22406.6(D) Receptacle Faceplate (Cover Plates) With Integral Night Light and/or USB Charger1 Question
- 4.23410.184 Ground-Fault Circuit-Interrupter (GFCI) Protection and Special Purpose Ground-Fault Circuit-Interrupter (SPGFCI) Protection
- 4.24410.184 Ground-Fault Circuit-Interrupter (GFCI) Protection and Special Purpose Ground-Fault Circuit-Interrupter (SPGFCI) Protection1 Question
- 4.25406.4(D) Receptacle Replacements
- 4.26406.4(D) Receptacle Replacements1 Question
- 4.27406.9 (C) Bathtub and Shower Space
- 4.28406.9 (C) Bathtub and Shower Space1 Question
- Article 500 Series32
- 5.1512.13 Wiring Installed Above Hazardous (Classified) Locations
- 5.2512.13 Wiring Installed Above Hazardous (Classified) Locations1 Question
- 5.3517.30(B) Power Sources for the EES
- 5.4517.30(B) Power Sources for the EES1 Question
- 5.5518.5 Supply
- 5.6518.5 Supply1 Question
- 5.7547.26 Physical Protection
- 5.8547.26 Physical Protection1 Question
- 5.9500.5 (D) Classifications of Locations
- 5.10500.5 (D) Classifications of Locations1 Question
- 5.11512.3(A) Cannabis Oil Equipment and Systems Other Than Booths
- 5.12512.3(A) Cannabis Oil Equipment and Systems Other Than Booths1 Question
- 5.13512.3(B) Cannabis Oil Booths
- 5.14512.3(B) Cannabis Oil Booths1 Question
- 5.15501.30 Grounding and Bonding
- 5.16501.30 Grounding and Bonding1 Question
- 5.17502.30 Grounding and Bonding
- 5.18502.30 Grounding and Bonding1 Question
- 5.19511.7(A) Wiring in Spaces Above Hazardous (Classified) Locations
- 5.20511.7(A) Wiring in Spaces Above Hazardous (Classified) Locations1 Question
- 5.21517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care Spaces
- 5.22517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care Spaces1 Question
- 5.23517.14 Panelboard Bonding
- 5.24517.14 Panelboard Bonding1 Question
- 5.25547.44 Equipotential Planes and Bonding of Equipotential Planes
- 5.26547.44 Equipotential Planes and Bonding of Equipotential Planes1 Question
- 5.27551.3 Electrical Datum Plane Distances
- 5.28551.3 Electrical Datum Plane Distances1 Question
- 5.29551.40 120-Volt or 120/240-Volt, Nominal, Systems1 Question
- 5.30551.40 120-Volt or 120/240-Volt, Nominal, Systems
- 5.31555.14 Equipotential Planes and Bonding of Equipotential Planes
- 5.32555.14 Equipotential Planes and Bonding of Equipotential Planes1 Question
- Article 600 Series44
- 6.1600.35 – Retrofit Kits
- 6.2600.35 – Retrofit Kits1 Question
- 6.3625.40 Electric Vehicle Branch Circuit
- 6.4625.40 Electric Vehicle Branch Circuit1 Question
- 6.5625.49 – Island Mode
- 6.6625.49 – Island Mode1 Question
- 6.7625.6 – Listed
- 6.8625.6 – Listed1 Question
- 6.9630.8 – Electric Welders
- 6.10630.8 – Electric Welders1 Question
- 6.11690.1 New illustration to help understand PV components
- 6.12690.1 New illustration to help understand PV components1 Question
- 6.13690.12 – Rapid Shutdown Requirements
- 6.14690.12 – Rapid Shutdown Requirements1 Question
- 6.15690.15 – Disconnecting Means for Isolating Photovoltaic Equipment
- 6.16690.15 – Disconnecting Means for Isolating Photovoltaic Equipment1 Question
- 6.17690.56 – Identification of Power Sources
- 6.18690.56 – Identification of Power Sources1 Question
- 6.19691.4 Special Requirements for Large-Scale PV Electric Supply Stations
- 6.20691.4 Special Requirements for Large-Scale PV Electric Supply Stations1 Question
- 6.21600.5(A) – Branch Circuits
- 6.22600.5(A) – Branch Circuits1 Question
- 6.23620.12(A) – Traveling Cables
- 6.24620.12(A) – Traveling Cables1 Question
- 6.25690.4(G) – PV Equipment Floating on Bodies of Water
- 6.26690.4(G) – PV Equipment Floating on Bodies of Water1 Question
- 6.27620.6 – GFCI Protection for Personnel
- 6.28620.6 – GFCI Protection for Personnel1 Question
- 6.29680.32 – GFCI and SPGFCI Protection
- 6.30680.32 – GFCI and SPGFCI Protection1 Question
- 6.31680.44 – GFCI & SPGFCI Protection
- 6.32680.44 – GFCI & SPGFCI Protection1 Question
- 6.33680.5 – GFCI and SPGFCI Protection
- 6.34680.5 – GFCI and SPGFCI Protection1 Question
- 6.35690.43 – Equipment Grounding and Bonding
- 6.36690.43 – Equipment Grounding and Bonding1 Question
- 6.37690.31 – Wiring Methods
- 6.38690.31 – Wiring Methods1 Question
- 6.39680.26(B)(2) – Equipotential Bonding – Perimeter Surfaces
- 6.40680.26(B)(2) – Equipotential Bonding – Perimeter Surfaces1 Question
- 6.41680.21(D) – Pool Pump Motor Replacement
- 6.42680.21(D) – Pool Pump Motor Replacement1 Question
- 6.43680.54(C) – Equipotential Bonding of Splash Pads
- 6.44680.54(C) – Equipotential Bonding of Splash Pads1 Question
- Article 700 Series28
- 7.1700.11 Wiring, Class-2-Powered Emergency Lighting Systems
- 7.2700.11 Wiring, Class-2-Powered Emergency Lighting Systems1 Question
- 7.3700.12(E) Stored-Energy Power Supply Systems (SEPSS)
- 7.4700.12(E) Stored-Energy Power Supply Systems (SEPSS)1 Question
- 7.5700.27 Class 2 Powered Emergency Lighting Systems
- 7.6700.27 Class 2 Powered Emergency Lighting Systems1 Question
- 7.7700.32 Selective Coordination
- 7.8700.32 Selective Coordination1 Question
- 7.9700.3(F) Temporary Source of Power for Maintenance or Repair of the Alternate Source of Power
- 7.10700.3(F) Temporary Source of Power for Maintenance or Repair of the Alternate Source of Power1 Question
- 7.11701.10 Wiring Legally Required Standby Systems
- 7.12701.10 Wiring Legally Required Standby Systems1 Question
- 7.13701.4(C) Load Management
- 7.14701.4(C) Load Management1 Question
- 7.15705.10 Identification of Power Sources
- 7.16705.10 Identification of Power Sources1 Question
- 7.17706.7 Commissioning and Maintenance
- 7.18706.7 Commissioning and Maintenance1 Question
- 7.19726.121 Power Sources for Class 4 Circuits
- 7.20726.121 Power Sources for Class 4 Circuits1 Question
- 7.21726.122 Class 4 Loads
- 7.22726.122 Class 4 Loads1 Question
- 7.23726.124 Class 4 Marking
- 7.24726.124 Class 4 Marking1 Question
- 7.25726.130 Terminals and Connectors
- 7.26726.130 Terminals and Connectors1 Question
- 7.27700.12(G) Microgrid Systems
- 7.28700.12(G) Microgrid Systems1 Question
- Article 800 Series6
