This course covers the essential calculations and theoretical principles required for sizing and protecting electrical systems under the NEC 2023 code. You will review the rules for determining conductor ampacity, permissible branch circuit loads, and the specific requirements for lighting outlets and kitchen island receptacles. The curriculum details critical load calculations for diverse environments, ranging from standard floor area and receptacle loads to specialized applications for marinas, boatyards, and Electric Vehicle Supply Equipment (EVSE).
Beyond basic circuit sizing, the training focuses on equipment ratings and system capacity. You will examine the requirements for overcurrent protection, including selective coordination, breaker ratings, and the use of copper-clad aluminum conductors. The course also addresses complex calculations for motor ampacities, HVAC equipment, and fire pump voltage drop, alongside the capacity rules for emergency systems, feeders, and energy management systems, ensuring you can accurately determine the requirements for both every day and critical power installations.
Course Features
- Lectures 31
- Quizzes 31
- Duration 52 weeks
- Skill level All levels
- Language English
- Students 0
- Certificate Yes
- Assessments Self
- 5 Sections
- 31 Lessons
- 52 Weeks
- NEC Courses Article 200 Series32
- 1.1210.19 Conductors – Minimum Ampacity and Size
- 1.2210.19 Conductors – Minimum Ampacity and Size1 Question
- 1.3210.23 Permissible Loads, Multiple-Outlet Branch Circuits
- 1.4210.23 Permissible Loads, Multiple-Outlet Branch Circuits1 Question
- 1.5210.70 Lighting Outlets Required
- 1.6210.70 Lighting Outlets Required1 Question
- 1.7220.110 Receptacle Loads
- 1.8220.110 Receptacle Loads1 Question
- 1.9220.120 Marinas, Boatyards, Floating Buildings, And Commercial and Noncommercial Docking Facilities
- 1.10220.120 Marinas, Boatyards, Floating Buildings, And Commercial and Noncommercial Docking Facilities1 Question
- 1.11220.57 Electric Vehicle Supply Equipment
- 1.12220.57 Electric Vehicle Supply Equipment1 Question
- 1.13220.70 Energy Management Systems (EMSs)
- 1.14220.70 Energy Management Systems (EMSs)1 Question
- 1.15215.15 Barriers
- 1.16215.15 Barriers1 Question
- 1.17210.52(C) Island and Peninsular Countertops and Work Surfaces
- 1.18210.52(C) Island and Peninsular Countertops and Work Surfaces1 Question
- 1.19220.5(C) Floor Areas
- 1.20220.5(C) Floor Areas1 Question
- 1.21230.71(B) Two to Six Disconnecting Means
- 1.22230.71(B) Two to Six Disconnecting Means1 Question
- 1.23240.11 Selective Coordination
- 1.24240.11 Selective Coordination1 Question
- 1.25240.4(B) Overcurrent Devices Rated 8000 Amperes or Less
- 1.26240.4(B) Overcurrent Devices Rated 8000 Amperes or Less1 Question
- 1.27240.4(D)(3) 14 AWG Copper-Clad Aluminum
- 1.28240.4(D)(3) 14 AWG Copper-Clad Aluminum1 Question
- 1.29Table 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers
- 1.30Table 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers1 Question
- 1.31Table 240.6(D) Remotely Accessible Adjustable-Trip Circuit Breakers
- 1.32Table 240.6(D) Remotely Accessible Adjustable-Trip Circuit Breakers1 Question
- NEC Courses Article 300 Series6
- NEC Courses Article 400 Series10
- 3.1404.14 Rating and Use of Switches
- 3.2404.14 Rating and Use of Switches1 Question
- 3.3406.3 Receptacle Rating and Type
- 3.4406.3 Receptacle Rating and Type1 Question
- 3.5422.18 Ceiling-Suspended (Paddle) Fans
- 3.6422.18 Ceiling-Suspended (Paddle) Fans1 Question
- 3.7430.6 Conductor Ampacity and Motor Rating Determination
- 3.8430.6 Conductor Ampacity and Motor Rating Determination1 Question
- 3.9440.8 Single Machine and Location
- 3.10440.8 Single Machine and Location1 Question
- NEC Courses Article 600 Series4
- NEC Courses Article 700 Series10
- 5.1700.4 Capacity and Rating
- 5.2700.4 Capacity and Rating1 Question
- 5.3705.12(A) Feeders and Feeder Taps
- 5.4705.12(A) Feeders and Feeder Taps1 Question
- 5.5726.144 Ampacity
- 5.6726.144 Ampacity1 Question
- 5.7700.12(C) Supply Duration
- 5.8700.12(C) Supply Duration1 Question
- 5.9750.30(C) Capacity of Branch Circuit, Feeder, or Service
- 5.10750.30(C) Capacity of Branch Circuit, Feeder, or Service1 Question




