This comprehensive NEC 2023 Code Update course keeps you compliant by covering some of the key changes across NEC Chapters 1 through 8. The curriculum begins with essential updates to general requirements, including new labeling rules for reconditioned equipment, arc-flash warnings on service equipment, and clarified processes for establishing electrically safe work conditions. You will also review expanded mandates for surge protection in residential and commercial panels, new emergency disconnect requirements, and the introduction of “Class 4” fault-managed power systems. The course ensures you are up to speed on the latest installation methods, from tamper-resistant receptacles and garage branch circuits to medium voltage cable terminations and insulated bus pipe systems.
Beyond standard installations, the training dives into specialized equipment and modern technologies transforming the industry. You will explore new code articles regulating cannabis oil processing facilities, germicidal irradiation systems, and electric vehicle branch circuits, including “island mode” capabilities. The course also provides a detailed look at renewable energy updates, such as rapid shutdown requirements for PV systems, floating solar arrays, and microgrid interconnections. With additional focus on emergency systems, selective coordination, and hazardous locations, this course offers a complete review of the safety standards affecting today’s most complex electrical projects.
Course Features
- Lectures 75
- Quizzes 75
- Duration 52 weeks
- Skill level All levels
- Language English
- Students 0
- Certificate Yes
- Assessments Self
- 8 Sections
- 75 Lessons
- 52 Weeks
- NEC Courses Article 100 Series14
- 1.1110.20 – Reconditioned Equipment
- 1.2110.20 – Reconditioned Equipment1 Question
- 1.3110.21 – Markings
- 1.4110.21 – Markings1 Question
- 1.5110.16(B) – Arc-Flash Hazard Warnings – Service Equipment
- 1.6110.16(B) – Arc-Flash Hazard Warnings – Service Equipment1 Question
- 1.7110.2(B) When Required
- 1.8110.2(B) When Required1 Question
- 1.9110.22(A) – Identification of Disconnecting Means
- 1.10110.22(A) – Identification of Disconnecting Means1 Question
- 1.11120.6 Process for Establishing and Verifying an Electrically Safe Work Condition
- 1.12120.6 Process for Establishing and Verifying an Electrically Safe Work Condition1 Question
- 1.13130.7(C)(5) Hearing Protection
- 1.14130.7(C)(5) Hearing Protection1 Question
- NEC Courses Article 200 Series20
- 2.1210.17 Guest Rooms and Guest Suites
- 2.2210.17 Guest Rooms and Guest Suites1 Question
- 2.3215.18 Surge Protection
- 2.4215.18 Surge Protection1 Question
- 2.5225.41 Emergency Disconnects
- 2.6225.41 Emergency Disconnects1 Question
- 2.7230.67 Surge Protection
- 2.8230.67 Surge Protection1 Question
- 2.9Article 235 – Branch Circuits, Feeders and Services over 1000 Volts AC, 1500 Volts DC, Nominal
- 2.10Article 235 – Branch Circuits, Feeders and Services over 1000 Volts AC, 1500 Volts DC, Nominal1 Question
- 2.11240.2 Reconditioned Equipment
- 2.12240.2 Reconditioned Equipment1 Question
- 2.13Article 245 – Overcurrent Protection over 1000 Volts AC, 1500 Volts DC
- 2.14Article 245 – Overcurrent Protection over 1000 Volts AC, 1500 Volts DC1 Question
- 2.15210.11(C)(4) Garage Branch Circuits
- 2.16210.11(C)(4) Garage Branch Circuits1 Question
- 2.17210.52(G) Basements, Garages, and Accessory Buildings
- 2.18210.52(G) Basements, Garages, and Accessory Buildings1 Question
- 2.19240.24(A) and (E) – Location in or on Premises
- 2.20240.24(A) and (E) – Location in or on Premises1 Question
- NEC Courses Article 300 Series22
- 3.1315.17 Marking for Type Medium Voltage Cable Joints, and Terminations
- 3.2315.17 Marking for Type Medium Voltage Cable Joints, and Terminations1 Question
- 3.3315.32 Uses Permitted for Type Medium Voltage Cables, Cable Joints, and Terminations
- 3.4315.32 Uses Permitted for Type Medium Voltage Cables, Cable Joints, and Terminations1 Question
- 3.5369.10 Uses Permitted for Insulated Bus Pipe (IBP) Systems
- 3.6369.10 Uses Permitted for Insulated Bus Pipe (IBP) Systems1 Question
- 3.7369.120 Marking Insulated Bus Pipe (IBP) Systems
- 3.8369.120 Marking Insulated Bus Pipe (IBP) Systems1 Question
- 3.9371.17 Overcurrent Protection of Flexible Bus System
- 3.10371.17 Overcurrent Protection of Flexible Bus System1 Question
- 3.11371.30 Securing and Supporting
- 3.12371.30 Securing and Supporting1 Question
- 3.13398.15 Exposed Work
- 3.14398.15 Exposed Work1 Question
- 3.15300.3 (C) Conductors of Different Systems
- 3.16300.3 (C) Conductors of Different Systems1 Question
- 3.17300.11(C) Raceways Used as Means of Support
- 3.18300.11(C) Raceways Used as Means of Support1 Question
- 3.19320.3(A)(1) Electrical Hazard Thresholds.
- 3.20320.3(A)(1) Electrical Hazard Thresholds.10 Minutes1 Question
- 3.21371.10 and 371.12 Uses Permitted and Not Permitted
- 3.22371.10 and 371.12 Uses Permitted and Not Permitted1 Question
- NEC Courses Article 400 Series22
- 4.1404.16 Reconditioned Equipment
- 4.2404.16 Reconditioned Equipment1 Question
- 4.3406.12 Tamper-Resistant Receptacles.
- 4.4406.12 Tamper-Resistant Receptacles.1 Question
- 4.5408.4 Descriptions Required
- 4.6408.4 Descriptions Required1 Question
- 4.7408.9 Replacement Panelboards
- 4.8408.9 Replacement Panelboards1 Question
- 4.9409.70 Surge Protection
- 4.10409.70 Surge Protection1 Question
- 4.11410.197 Germicidal Irradiation Systems
- 4.12410.197 Germicidal Irradiation Systems1 Question
- 4.13410.71(1) General
- 4.14410.71(1) General1 Question
- 4.15430.2 Reconditioned Motors
- 4.16430.2 Reconditioned Motors1 Question
- 4.17445.19 Emergency Shutdown of Prime Mover
- 4.18445.19 Emergency Shutdown of Prime Mover1 Question
- 4.19470.2 Reconditioned Equipment
- 4.20470.2 Reconditioned Equipment1 Question
- 4.21406.6(D) Receptacle Faceplate (Cover Plates) With Integral Night Light and/or USB Charger
- 4.22406.6(D) Receptacle Faceplate (Cover Plates) With Integral Night Light and/or USB Charger1 Question
- NEC Courses Article 500 Series14
- 5.1512.13 Wiring Installed Above Hazardous (Classified) Locations
- 5.2512.13 Wiring Installed Above Hazardous (Classified) Locations1 Question
- 5.3517.30(B) Power Sources for the EES
- 5.4517.30(B) Power Sources for the EES1 Question
- 5.5518.5 Supply
- 5.6518.5 Supply1 Question
- 5.7547.26 Physical Protection
- 5.8547.26 Physical Protection1 Question
- 5.9500.5 (D) Classifications of Locations
- 5.10500.5 (D) Classifications of Locations1 Question
- 5.11512.3(A) Cannabis Oil Equipment and Systems Other Than Booths
- 5.12512.3(A) Cannabis Oil Equipment and Systems Other Than Booths1 Question
- 5.13512.3(B) Cannabis Oil Booths
- 5.14512.3(B) Cannabis Oil Booths1 Question
- NEC Courses Article 600 Series26
- 6.1600.35 – Retrofit Kits
- 6.2600.35 – Retrofit Kits1 Question
- 6.3625.40 Electric Vehicle Branch Circuit
- 6.4625.40 Electric Vehicle Branch Circuit1 Question
- 6.5625.49 – Island Mode
- 6.6625.49 – Island Mode1 Question
- 6.7625.6 – Listed
- 6.8625.6 – Listed1 Question
- 6.9630.8 – Electric Welders
- 6.10630.8 – Electric Welders1 Question
- 6.11690.1 New illustration to help understand PV components
- 6.12690.1 New illustration to help understand PV components1 Question
- 6.13690.12 – Rapid Shutdown Requirements
- 6.14690.12 – Rapid Shutdown Requirements1 Question
- 6.15690.15 – Disconnecting Means for Isolating Photovoltaic Equipment
- 6.16690.15 – Disconnecting Means for Isolating Photovoltaic Equipment1 Question
- 6.17690.56 – Identification of Power Sources
- 6.18690.56 – Identification of Power Sources1 Question
- 6.19691.4 Special Requirements for Large-Scale PV Electric Supply Stations
- 6.20691.4 Special Requirements for Large-Scale PV Electric Supply Stations1 Question
- 6.21600.5(A) – Branch Circuits
- 6.22600.5(A) – Branch Circuits1 Question
- 6.23620.12(A) – Traveling Cables
- 6.24620.12(A) – Traveling Cables1 Question
- 6.25690.4(G) – PV Equipment Floating on Bodies of Water
- 6.26690.4(G) – PV Equipment Floating on Bodies of Water1 Question
- NEC Courses Article 700 Series28
- 7.1700.11 Wiring, Class-2-Powered Emergency Lighting Systems
- 7.2700.11 Wiring, Class-2-Powered Emergency Lighting Systems1 Question
- 7.3700.12(E) Stored-Energy Power Supply Systems (SEPSS)
- 7.4700.12(E) Stored-Energy Power Supply Systems (SEPSS)1 Question
- 7.5700.27 Class 2 Powered Emergency Lighting Systems
- 7.6700.27 Class 2 Powered Emergency Lighting Systems1 Question
- 7.7700.32 Selective Coordination
- 7.8700.32 Selective Coordination1 Question
- 7.9700.3(F) Temporary Source of Power for Maintenance or Repair of the Alternate Source of Power
- 7.10700.3(F) Temporary Source of Power for Maintenance or Repair of the Alternate Source of Power1 Question
- 7.11701.10 Wiring Legally Required Standby Systems
- 7.12701.10 Wiring Legally Required Standby Systems1 Question
- 7.13701.4(C) Load Management
- 7.14701.4(C) Load Management1 Question
- 7.15705.10 Identification of Power Sources
- 7.16705.10 Identification of Power Sources1 Question
- 7.17706.7 Commissioning and Maintenance
- 7.18706.7 Commissioning and Maintenance1 Question
- 7.19726.121 Power Sources for Class 4 Circuits
- 7.20726.121 Power Sources for Class 4 Circuits1 Question
- 7.21726.122 Class 4 Loads
- 7.22726.122 Class 4 Loads1 Question
- 7.23726.124 Class 4 Marking
- 7.24726.124 Class 4 Marking1 Question
- 7.25726.130 Terminals and Connectors
- 7.26726.130 Terminals and Connectors1 Question
- 7.27700.12(G) Microgrid Systems
- 7.28700.12(G) Microgrid Systems1 Question
- NEC Courses Article 800 Series4