This 8-hour online course for Alaska Electrical Administrators covers critical NEC updates for Special Occupancies and Equipment.
The curriculum details requirements for Hazardous (Classified) Locations (Art. 511, 512, 517), as well as GFCI rules for pools (Art. 680) and disconnects for signs (Art. 600). The program then covers modern power systems, including Electric Vehicle Supply Equipment (Art. 625), Solar PV rapid shutdown (690.12), and Emergency Systems (Art. 700). The course concludes with a review of interconnected power sources, Energy Storage Systems (Art. 706), and the new Class 4 (CL4) power systems (Art. 726).
Course Features
- Lectures 64
- Quizzes 64
- Duration 52 weeks
- Skill level All levels
- Language English
- Students 0
- Certificate Yes
- Assessments Self
- 4 Sections
- 64 Lessons
- 52 Weeks
- NEC Courses Article 400 Series12
- 1.1440.8 Single Machine and Location
- 1.2440.8 Single Machine and Location1 Question
- 1.3445.19 Emergency Shutdown of Prime Mover
- 1.4445.19 Emergency Shutdown of Prime Mover1 Question
- 1.5470.2 Reconditioned Equipment
- 1.6470.2 Reconditioned Equipment1 Question
- 1.7406.4(D) Receptacle Replacements
- 1.8406.4(D) Receptacle Replacements1 Question
- 1.9406.6(D) Receptacle Faceplate (Cover Plates) With Integral Night Light and/or USB Charger
- 1.10406.6(D) Receptacle Faceplate (Cover Plates) With Integral Night Light and/or USB Charger1 Question
- 1.11406.9 (C) Bathtub and Shower Space
- 1.12406.9 (C) Bathtub and Shower Space1 Question
- NEC Courses Article 500 Series36
- 2.1501.30 Grounding and Bonding
- 2.2501.30 Grounding and Bonding1 Question
- 2.3502.30 Grounding and Bonding
- 2.4502.30 Grounding and Bonding1 Question
- 2.5511.7(A) Wiring in Spaces Above Hazardous (Classified) Locations
- 2.6511.7(A) Wiring in Spaces Above Hazardous (Classified) Locations1 Question
- 2.7512.13 Wiring Installed Above Hazardous (Classified) Locations
- 2.8512.13 Wiring Installed Above Hazardous (Classified) Locations1 Question
- 2.9512.20 Equipment and Systems
- 2.10512.20 Equipment and Systems1 Question
- 2.11517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care Spaces
- 2.12517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care Spaces1 Question
- 2.13517.14 Panelboard Bonding
- 2.14517.14 Panelboard Bonding1 Question
- 2.15517.30(B) Power Sources for the EES
- 2.16517.30(B) Power Sources for the EES1 Question
- 2.17518.4 Wiring Methods
- 2.18518.4 Wiring Methods1 Question
- 2.19518.5 Supply
- 2.20518.5 Supply1 Question
- 2.21547.26 Physical Protection
- 2.22547.26 Physical Protection1 Question
- 2.23547.44 Equipotential Planes and Bonding of Equipotential Planes
- 2.24547.44 Equipotential Planes and Bonding of Equipotential Planes1 Question
- 2.25551.3 Electrical Datum Plane Distances
- 2.26551.3 Electrical Datum Plane Distances1 Question
- 2.27551.40 120-Volt or 120/240-Volt, Nominal, Systems
- 2.28551.40 120-Volt or 120/240-Volt, Nominal, Systems1 Question
- 2.29555.14 Equipotential Planes and Bonding of Equipotential Planes
- 2.30555.14 Equipotential Planes and Bonding of Equipotential Planes1 Question
- 2.31500.5 (D) Classifications of Locations
- 2.32500.5 (D) Classifications of Locations1 Question
- 2.33512.3(A) Cannabis Oil Equipment and Systems Other Than Booths
- 2.34512.3(A) Cannabis Oil Equipment and Systems Other Than Booths1 Question
- 2.35512.3(B) Cannabis Oil Booths
- 2.36512.3(B) Cannabis Oil Booths1 Question
- NEC Courses Article 600 Series40
- 3.1600.35 – Retrofit Kits
- 3.2600.35 – Retrofit Kits1 Question
- 3.3600.6 – Disconnects
- 3.4600.6 – Disconnects1 Question
- 3.5620.36 – Different Systems in One Raceway or Traveling Cable.
- 3.6620.36 – Different Systems in One Raceway or Traveling Cable.1 Question
- 3.7620.6 – GFCI Protection for Personnel
- 3.8620.6 – GFCI Protection for Personnel1 Question
- 3.9625.40 Electric Vehicle Branch Circuit
- 3.10625.40 Electric Vehicle Branch Circuit1 Question
- 3.11625.42 Rating
- 3.12625.42 Rating1 Question
- 3.13625.49 – Island Mode
- 3.14625.49 – Island Mode1 Question
- 3.15625.6 – Listed
- 3.16625.6 – Listed1 Question
- 3.17630.8 – Electric Welders
- 3.18630.8 – Electric Welders1 Question
- 3.19646.19 – Entrance to and Egress from Working Space
- 3.20646.19 – Entrance to and Egress from Working Space1 Question
- 3.21680.10 – Pool Water Temperature Conditioning Equipment
- 3.22680.10 – Pool Water Temperature Conditioning Equipment1 Question
- 3.23680.12 – Equipment Rooms, Vaults, and Pits
- 3.24680.12 – Equipment Rooms, Vaults, and Pits1 Question
- 3.25680.14 Corrosive Environments
- 3.26680.14 Corrosive Environments1 Question
- 3.27680.32 – GFCI and SPGFCI Protection
- 3.28680.32 – GFCI and SPGFCI Protection1 Question
- 3.29680.44 – GFCI & SPGFCI Protection
- 3.30680.44 – GFCI & SPGFCI Protection1 Question
- 3.31680.5 – GFCI and SPGFCI Protection
- 3.32680.5 – GFCI and SPGFCI Protection1 Question
- 3.33690.1 New illustration to help understand PV components
- 3.34690.1 New illustration to help understand PV components1 Question
- 3.35690.12 – Rapid Shutdown Requirements
- 3.36690.12 – Rapid Shutdown Requirements1 Question
- 3.37690.15 – Disconnecting Means for Isolating Photovoltaic Equipment
- 3.38690.15 – Disconnecting Means for Isolating Photovoltaic Equipment1 Question
- 3.39690.43 – Equipment Grounding and Bonding
- 3.40690.43 – Equipment Grounding and Bonding1 Question
- NEC Courses Article 700 Series40
- 4.1700.11 Wiring, Class-2-Powered Emergency Lighting Systems
- 4.2700.11 Wiring, Class-2-Powered Emergency Lighting Systems1 Question
- 4.3700.27 Class 2 Powered Emergency Lighting Systems
- 4.4700.27 Class 2 Powered Emergency Lighting Systems1 Question
- 4.5700.32 Selective Coordination
- 4.6700.32 Selective Coordination1 Question
- 4.7700.4 Capacity and Rating
- 4.8700.4 Capacity and Rating1 Question
- 4.9701.10 Wiring Legally Required Standby Systems
- 4.10701.10 Wiring Legally Required Standby Systems1 Question
- 4.11702.12 Outdoor Generator Sets
- 4.12702.12 Outdoor Generator Sets1 Question
- 4.13702.5 Interconnection or Transfer Equipment
- 4.14702.5 Interconnection or Transfer Equipment1 Question
- 4.15705.10 Identification of Power Sources
- 4.16705.10 Identification of Power Sources1 Question
- 4.17705.30 Overcurrent Protection
- 4.18705.30 Overcurrent Protection1 Question
- 4.19705.50 System Operation
- 4.20705.50 System Operation1 Question
- 4.21706.7 Commissioning and Maintenance
- 4.22706.7 Commissioning and Maintenance1 Question
- 4.23726.121 Power Sources for Class 4 Circuits
- 4.24726.121 Power Sources for Class 4 Circuits1 Question
- 4.25726.122 Class 4 Loads
- 4.26726.122 Class 4 Loads1 Question
- 4.27726.124 Class 4 Marking
- 4.28726.124 Class 4 Marking1 Question
- 4.29726.130 Terminals and Connectors
- 4.30726.130 Terminals and Connectors1 Question
- 4.31726.136(E) Enclosures with Single Openings
- 4.32726.136(E) Enclosures with Single Openings1 Question
- 4.33726.144 Ampacity
- 4.34726.144 Ampacity1 Question
- 4.35700.12(C) Supply Duration
- 4.36700.12(C) Supply Duration1 Question
- 4.37700.12(E) Stored-Energy Power Supply Systems (SEPSS)
- 4.38700.12(E) Stored-Energy Power Supply Systems (SEPSS)1 Question
- 4.39700.12(G) Microgrid Systems
- 4.40700.12(G) Microgrid Systems1 Question





