This 8-hour online course fulfills the complete continuing education requirement for Alaska Electrical Administrators. The program provides a deep dive into critical NEC updates, focusing on service and feeder calculations, new loads for Electric Vehicle Supply Equipment (220.57), and Energy Management Systems (220.70). It also covers significant changes to emergency disconnects (230.85), surge protection (230.67), and the proper use of reconditioned equipment (110.20).
The curriculum integrates essential installation practices, such as box fill calculations (314.16), working space requirements (110.26), and GFCI protection (410.184). A key component of the course is a thorough review of NFPA 70E safety standards. This includes mandatory topics like job safety planning (110.3(I)) and the formal process for establishing and verifying an electrically safe work condition (120.6), ensuring you are current with all applicable codes and safety protocols.
Course Features
- Lectures 65
- Quizzes 65
- Duration 52 weeks
- Skill level All levels
- Language English
- Students 3
- Certificate Yes
- Assessments Self
- 5 Sections
- 65 Lessons
- 52 Weeks
- NEC Courses Article 100 Series30
- 1.1100 – Definitions
- 1.2100 – Definitions1 Question
- 1.3110.17 – Servicing and Maintenance of Equipment
- 1.4110.17 – Servicing and Maintenance of Equipment1 Question
- 1.5110.20 – Reconditioned Equipment
- 1.6110.20 – Reconditioned Equipment1 Question
- 1.7110.21 – Markings
- 1.8110.21 – Markings1 Question
- 1.9110.26 – Spaces About Electrical Equipment
- 1.10110.26 – Spaces About Electrical Equipment1 Question
- 1.11110.29 – In Sight From
- 1.12110.29 In Sight From1 Question
- 1.13110.3 – Examination, Identification, Installation, Use, and Listing (Product Certification) of Equipment.
- 1.14110.3 – Examination, Identification, Installation, Use, and Listing (Product Certification) of Equipment.1 Question
- 1.15110.14(A) – Electrical Connections – Terminals
- 1.16110.14(A) – Electrical Connections – Terminals1 Question
- 1.17110.16(B) – Arc-Flash Hazard Warnings – Service Equipment
- 1.18110.16(B) – Arc-Flash Hazard Warnings – Service Equipment1 Question
- 1.19110.2(B) When Required
- 1.20110.2(B) When Required1 Question
- 1.21110.22(A) – Identification of Disconnecting Means
- 1.22110.22(A) – Identification of Disconnecting Means1 Question
- 1.23110.3(I) Job Safety Planning and Job Briefing
- 1.24110.3(I) Job Safety Planning and Job Briefing1 Question
- 1.25110.33(A) and 110.34(A)
- 1.26110.33(A) and 110.34(A)1 Question
- 1.27110.33(A) and 110.34(A)
- 1.28110.33(A) and 110.34(A)1 Question
- 1.29120.6 Process for Establishing and Verifying an Electrically Safe Work Condition
- 1.30120.6 Process for Establishing and Verifying an Electrically Safe Work Condition1 Question
- NEC Courses Article 200 Series30
- 2.1210.17 Guest Rooms and Guest Suites
- 2.2210.17 Guest Rooms and Guest Suites1 Question
- 2.3210.19 Conductors – Minimum Ampacity and Size
- 2.4210.19 Conductors – Minimum Ampacity and Size1 Question
- 2.5210.23 Permissible Loads, Multiple-Outlet Branch Circuits
- 2.6210.23 Permissible Loads, Multiple-Outlet Branch Circuits1 Question
- 2.7210.70 Lighting Outlets Required
- 2.8210.70 Lighting Outlets Required1 Question
- 2.9215.15 Barriers
- 2.10215.15 Barriers1 Question
- 2.11215.18 Surge Protection
- 2.12215.18 Surge Protection1 Question
- 2.13220.1 Scope
- 2.14220.1 Scope1 Question
- 2.15220.110 Receptacle Loads
- 2.16220.110 Receptacle Loads1 Question
- 2.17220.120 Marinas, Boatyards, Floating Buildings, And Commercial and Noncommercial Docking Facilities
- 2.18220.120 Marinas, Boatyards, Floating Buildings, And Commercial and Noncommercial Docking Facilities1 Question
- 2.19220.57 Electric Vehicle Supply Equipment
- 2.20220.57 Electric Vehicle Supply Equipment1 Question
- 2.21220.70 Energy Management Systems (EMSs)
- 2.22220.70 Energy Management Systems (EMSs)1 Question
- 2.23225.41 Emergency Disconnects
- 2.24225.41 Emergency Disconnects1 Question
- 2.25230.67 Surge Protection
- 2.26230.67 Surge Protection1 Question
- 2.27230.85 Emergency Disconnects
- 2.28230.85 Emergency Disconnects1 Question
- 2.29Article 235 – Branch Circuits, Feeders and Services over 1000 Volts AC, 1500 Volts DC, Nominal
- 2.30Article 235 – Branch Circuits, Feeders and Services over 1000 Volts AC, 1500 Volts DC, Nominal1 Question
- NEC Courses Article 300 Series30
- 3.1300.14 Length of Free Conductors at Outlets, Junctions, and Switch Points
- 3.2300.14 Length of Free Conductors at Outlets, Junctions, and Switch Points1 Question
- 3.3312.10 Screws or Other Fasteners
- 3.4312.10 Screws or Other Fasteners1 Question
- 3.5314.16 Box Fill Calculations
- 3.6314.16 Box Fill Calculations1 Question
- 3.7314.24 Dimensions of Boxes
- 3.8314.24 Dimensions of Boxes1 Question
- 3.9314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible
- 3.10314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible1 Question
- 3.11314.5 Screws or Other Fasteners
- 3.12314.5 Screws or Other Fasteners1 Question
- 3.13315.17 Marking for Type Medium Voltage Cable Joints, and Terminations
- 3.14315.17 Marking for Type Medium Voltage Cable Joints, and Terminations1 Question
- 3.15315.32 Uses Permitted for Type Medium Voltage Cables, Cable Joints, and Terminations
- 3.16315.32 Uses Permitted for Type Medium Voltage Cables, Cable Joints, and Terminations1 Question
- 3.17320.23 In Accessible Attics
- 3.18320.23 In Accessible Attics1 Question
- 3.19334.10 Uses Permitted
- 3.20334.10 Uses Permitted1 Question
- 3.21334.15 (B) Protection from Physical Damage
- 3.22334.15 (B) Protection from Physical Damage1 Question
- 3.23342.20 Size
- 3.24342.20 Size1 Question
- 3.25352.10 Uses Permitted for Rigid Polyvinyl Chloride Conduits
- 3.26352.10 Uses Permitted for Rigid Polyvinyl Chloride Conduits1 Question
- 3.27352.44 Expansion Fittings
- 3.28352.44 Expansion Fittings1 Question
- 3.29356.10 Uses Permitted
- 3.30356.10 Uses Permitted1 Question
- NEC Courses Article 400 Series30
- 4.1404.14 Rating and Use of Switches
- 4.2404.14 Rating and Use of Switches1 Question
- 4.3404.16 Reconditioned Equipment
- 4.4404.16 Reconditioned Equipment1 Question
- 4.5404.30 Switch Enclosures with Doors
- 4.6404.30 Switch Enclosures with Doors1 Question
- 4.7406.12 Tamper-Resistant Receptacles.
- 4.8406.12 Tamper-Resistant Receptacles.1 Question
- 4.9406.3 Receptacle Rating and Type
- 4.10406.3 Receptacle Rating and Type1 Question
- 4.11408.38 Enclosure
- 4.12408.38 Enclosure1 Question
- 4.13408.4 Descriptions Required
- 4.14408.4 Descriptions Required1 Question
- 4.15408.9 Replacement Panelboards
- 4.16408.9 Replacement Panelboards1 Question
- 4.17409.70 Surge Protection
- 4.18409.70 Surge Protection1 Question
- 4.19410.10 Luminaires in Specific Locations
- 4.20410.10 Luminaires in Specific Locations1 Question
- 4.21410.184 Ground-Fault Circuit-Interrupter (GFCI) Protection and Special Purpose Ground-Fault Circuit-Interrupter (SPGFCI) Protection
- 4.22410.184 Ground-Fault Circuit-Interrupter (GFCI) Protection and Special Purpose Ground-Fault Circuit-Interrupter (SPGFCI) Protection1 Question
- 4.23410.195 Locations Not Permitted
- 4.24410.195 Locations Not Permitted1 Question
- 4.25410.197 Germicidal Irradiation Systems
- 4.26410.197 Germicidal Irradiation Systems1 Question
- 4.27410.71(1) General
- 4.28410.71(1) General1 Question
- 4.29422.18 Ceiling-Suspended (Paddle) Fans
- 4.30422.18 Ceiling-Suspended (Paddle) Fans1 Question
- NFPA NEC Chapters10
- 5.1110.2(B) When Required
- 5.2110.2(B) When Required1 Question
- 5.3110.3(I) Job Safety Planning and Job Briefing
- 5.4110.3(I) Job Safety Planning and Job Briefing1 Question
- 5.5120.6 Process for Establishing and Verifying an Electrically Safe Work Condition
- 5.6120.6 Process for Establishing and Verifying an Electrically Safe Work Condition1 Question
- 5.7130.7(C)(5) Hearing Protection
- 5.8130.7(C)(5) Hearing Protection1 Question
- 5.9320.3(A)(1) Electrical Hazard Thresholds.
- 5.10320.3(A)(1) Electrical Hazard Thresholds.10 Minutes1 Question